The DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.
Digital microfluidics: a versatile tool for applications in chemistry, biology and medicine
Abstract
Digital microfluidics (DMF) has recently emerged as a popular technology for a wide range of applications. In DMF, nanoliter to microliter droplets containing samples and reagents can be manipulated to carry out a range of discrete fluidic operations simply by applying a series of electrical potentials to an array of patterned electrodes coated with a hydrophobic insulator. DMF is distinct from microchannel-based fluidics as it allows for precise control over multiple reagent phases (liquids and solids) in heterogeneous systems with no need for complex networks of connections, microvalves, or pumps. In this review, we discuss the most recent developments in this technology with particular attention to the potential benefits and outstanding challenges for applications in chemistry, biology, and medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Electrodynamics
Griffiths, D. J. (2017) · Cambridge University Press eBooks · doi:10.1017/9781108333511 · Cited by 3,408
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Cho, S. K., Moon, H., & Kim, C.-J. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.807467 · Cited by 1,598
Electrowetting-based actuation of liquid droplets for microfluidic applications
Pollack, M. G., Fair, R. B., & Shenderov, A. D. (2000) · Applied Physics Letters · doi:10.1063/1.1308534 · Cited by 1,481
Srinivasan, V., Pamula, V. K., & Fair, R. B. (2004) · Lab on a Chip · doi:10.1039/b403341h · Cited by 1,066
Microdroplets in Microfluidics: An Evolving Platform for Discoveries in Chemistry and Biology
Theberge, A. B., Courtois, F., Schaerli, Y., Fischlechner, M., Abell, C., Hollfelder, F., & Huck, W. T. S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906653 · Cited by 1,059
Synthesis of micro and nanostructures in microfluidic systems
Marre, S., & Jensen, K. F. (2010) · Chemical Society Reviews · doi:10.1039/b821324k · Cited by 734
Electrowetting and electrowetting-on-dielectric for microscale liquid handling
Lee, J., Moon, H., Fowler, J., Schoellhammer, T., & Kim, C.-J. (2002) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(01)00734-8 · Cited by 652
Development of a digital microfluidic platform for point of care testing
Sista, R., Hua, Z., Thwar, P., Sudarsan, A., Srinivasan, V., Eckhardt, A., Pollack, M., & Pamula, V. (2008) · Lab on a Chip · doi:10.1039/b814922d · Cited by 550
Fan, R., Vermesh, O., Srivastava, A., Yen, B. K. H., Qin, L., Ahmad, H., Kwong, G. A., Liu, C.-C., Gould, J., Hood, L., et al. (2008) · Nature Biotechnology · doi:10.1038/nbt.1507 · Cited by 539
Cited by
Emerging Droplet Microfluidics
Shang, L., Cheng, Y., & Zhao, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00848 · Cited by 1,584
A review of digital microfluidics as portable platforms for lab-on a-chip applications
Samiei, E., Tabrizian, M., & Hoorfar, M. (2016) · Lab on a Chip · doi:10.1039/c6lc00387g · Cited by 471
Magnetic digital microfluidics – a review
Zhang, Y., & Nguyen, N.-T. (2017) · Lab on a Chip · doi:10.1039/c7lc00025a · Cited by 364
Electrochemistry, biosensors and microfluidics: a convergence of fields
Rackus, D. G., Shamsi, M. H., & Wheeler, A. R. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00369a · Cited by 354
The use of mass spectrometry to analyze dried blood spots
Wagner, M., Tonoli, D., Varesio, E., & Hopfgartner, G. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21441 · Cited by 262
Digital microfluidics for spheroid-based invasion assays
Bender, B. F., Aijian, A. P., & Garrell, R. L. (2016) · Lab on a Chip · doi:10.1039/c5lc01569c · Cited by 49
Metadata
- Authors
- Jebrail, M. J., Bartsch, M. S., & Patel, K. D.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 14
- Pages
- 2452
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1967411109
- Cited by
- 324
- References
- 64
- FWCI
- 18.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.