Label-free methods of reporting biomolecular interactions by optical biosensors
The DOI matches its Crossref record.
Abstract
Reporting biomolecular interactions has become part and parcel of many applications of science towards an in-depth understanding of disease and gene regulation. Apart from that, in diagnostic applications where biomolecules (antibodies and aptamers) are vastly applied, meticulous monitoring of biomolecular interaction is vital for clear-cut diagnosis. Several currently available methods of analyzing the interaction of the ligands with the appropriate analytes are aided by labeling using fluorescence or luminescence techniques. However, labeling is cumbersome and can occupy important binding sites of interactive molecules to be labeled, which may interfere with the conformational changes of the molecules and increase non-specificity. Optical-based sensing can provide an alternative way as a label-free procedure for monitoring biomolecular interactions. Optical sensors affiliated with different operating principles, including surface plasmon changes, scattering and interferometry, can impart a huge impact for in-house and point-of-care applications. This optical-based biosensing permits real-time monitoring, obviating the use of hazardous labeling molecules such as radioactive tags. Herein, label-free ways of reporting biomolecular interactions by various optical biosensors were gleaned.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent Advances in Biosensor Technology for Potential Applications – An Overview
Vigneshvar, S., Sudhakumari, C. C., Senthilkumaran, B., & Prakash, H. (2016) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2016.00011 · Cited by 674
Luka, G., Ahmadi, A., Najjaran, H., Alocilja, E., DeRosa, M., Wolthers, K., Malki, A., Aziz, H., Althani, A., & Hoorfar, M. (2015) · Sensors · doi:10.3390/s151229783 · Cited by 566
Advances and challenges in biosensor-based diagnosis of infectious diseases
Sin, M. L., Mach, K. E., Wong, P. K., & Liao, J. C. (2014) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.2014.888313 · Cited by 435
Progress of new label-free techniques for biosensors: a review
Sang, S., Wang, Y., Feng, Q., Wei, Y., Ji, J., & Zhang, W. (2015) · Critical Reviews in Biotechnology · doi:10.3109/07388551.2014.991270 · Cited by 272
Jiang, Z.-Y., Lu, M.-C., Xu, L., Yang, T.-T., Xi, M.-Y., Xu, X.-L., Guo, X.-K., Zhang, X.-J., You, Q.-D., & Sun, H.-P. (2014) · Journal of Medicinal Chemistry · doi:10.1021/jm5000529 · Cited by 252
Holographic Sensors: Three-Dimensional Analyte-Sensitive Nanostructures and Their Applications
Yetisen, A. K., Naydenova, I., da Cruz Vasconcellos, F., Blyth, J., & Lowe, C. R. (2014) · Chemical Reviews · doi:10.1021/cr500116a · Cited by 224
Futuristic biosensors for cardiac health care: an artificial intelligence approach
Vashistha, R., Dangi, A. K., Kumar, A., Chhabra, D., & Shukla, P. (2018) · 3 Biotech · doi:10.1007/s13205-018-1368-y · Cited by 113
Binding thermodynamics and kinetics guided optimization of potent Keap1–Nrf2 peptide inhibitors
Lu, M.-C., Chen, Z.-Y., Wang, Y.-L., Jiang, Y.-L., Yuan, Z.-W., You, Q.-D., & Jiang, Z.-Y. (2015) · RSC Advances · doi:10.1039/c5ra16262a · Cited by 55
Metadata
- Authors
- Citartan, M., Gopinath, S. C. B., Tominaga, J., & Tang, T.-H.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 138
- Issue
- 13
- Pages
- 3576
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2078701568
- Cited by
- 98
- References
- 0
- FWCI
- 4.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.