Determination of triazole pesticides in rat blood by the combination of ultrasound-enhanced temperature-controlled ionic liquid dispersive liquid–liquid microextraction coupled to high-performance liquid chromatography
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
This paper presents a study of the performance of ultrasound-enhanced temperature-controlled (UETC) ionic liquid dispersive liquid–liquid microextraction (IL-DLLME). The use of ultrasonication and heating can enhance the ability of the ionic liquid to extract the analytes. Various parameters that would affect the extraction efficiency, such as the type and volume of the extraction and dispersing solvents, salt concentration, pH value, centrifugation time, effect of temperature on UETC-IL-DLLME, were investigated and optimized. Under the optimal extraction conditions, good enrichment factors (178–197) and recoveries (88.9–98.5%) were obtained. Good linearity was obtained in the range of 4–500 μg L−1 for myclobutanil and in the range of 6–500 μg L−1 for uniconazole, penconazole, tebuconazole and hexaconazole. Based on the optimized conditions, the UETC-IL-DLLME method was applied and combined with high-performance liquid chromatography with diode array detection (HPLC-DAD) to determine the presence of five triazole fungicides. The results showed that the method we proposed could effectively determine the target fungicides in rat blood samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Extraction of organic compounds with room temperature ionic liquids
Poole, C. F., & Poole, S. K. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.09.011 · Cited by 493
Yao, C., & Anderson, J. L. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3078-0 · Cited by 204
Leong, M.-I., & Huang, S.-D. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.09.004 · Cited by 151
Pusvaskiene, E., Januskevic, B., Prichodko, A., & Vickackaite, V. (2009) · Chromatographia · doi:10.1365/s10337-008-0885-y · Cited by 57
Cited by
Non-conventional solvents in liquid phase microextraction and aqueous biphasic systems
An, J., Trujillo-Rodríguez, M. J., Pino, V., & Anderson, J. L. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.04.012 · Cited by 128
Ten years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
Wang, H., Yang, X., Hu, L., Gao, H., Lu, R., Zhang, S., & Zhou, W. (2016) · New Journal of Chemistry · doi:10.1039/c5nj03376d · Cited by 40
Self-citationBazmandegan‐Shamili, A., Dadfarnia, S., Shabani, A. M. H., Moghadam, M. R., & Saeidi, M. (2018) · Journal of Separation Science · doi:10.1002/jssc.201701427 · Cited by 25
Metadata
- Authors
- Li, Y., Zhang, J., Peng, B., Li, S., Gao, H., & Zhou, W.
- Venue
- Analytical Methods
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 5
- Issue
- 9
- Pages
- 2241
- ISSN
- 1759-9660 (ISSN-L)
- 1759-9679
- OpenAlex
- W2141030578
- Cited by
- 28
- References
- 4
- FWCI
- 3.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.