CoChat

A conically fixed position single drop microextraction method for isolation of aryloxyphenoxypropionate herbicides from aquatic media

Bagheri, Habib, Dehghan, Milad, Es'haghi, Ali, Naderi, Mehrnoush · 2013 · Analytical Methods
Cited by 21

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

A new and convenient format of single drop microextraction (SDME) was developed and applied for isolation of some selected aryloxyphenoxypropionate herbicides from aquatic media. In contrast to the conventional SDME procedure, in this set-up the extraction microdrop was positioned at the bottom of a conical vial in order to provide much higher stability for the organic extraction phase while a magnetic bar was used for stirring the aqueous solution. A simple magnet was used for positioning the bar on the top of the microdrop prior to stirring. The whole set-up led to the use of any volume of extraction solvent with unlimited stirring rates. Some important extraction parameters such as the type of solvent, stirring rate, temperature and extraction time were investigated and optimized. Selection of a microdrop volume of 3 μL with a sampling time of 35 min along with the use of carbon tetrachloride as the most appropriate solvent led to the highest enrichment factors. The linearity was studied by preconcentration of 1 mL of water samples spiked with a standard solution of aryloxyphenoxypropionates in the concentration range of 0.1–300 μg L−1. The coefficient of determination was satisfactory (r2 > 0.99) for all the studied analytes and the relative standard deviation (RSD%) values under the optimized conditions were found to be in the range of 5.1 to 10.1% at the concentrations of 0.6 and 50 μg L−1. Detection limits were obtained to be in the range of 0.02–0.05 μg L−1 using time-scheduled selected ion monitoring (SIM). The developed method was successfully applied for the extraction and determination of aryloxyphenoxypropionates in river water samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c3ay40817e

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 21

Metadata

Authors
Bagheri, H., Dehghan, M., Es'haghi, A., & Naderi, M.
Venue
Analytical Methods
Published
2013
Volume
5
Issue
18
Pages
4846
ISSN
  • 1759-9660 (ISSN-L)
  • 1759-9679
OpenAlex
W2091298268
Cited by
21
References
1
FWCI
3.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A conically fixed position single drop microextraction method for isolation of aryloxyphenoxypropionate herbicides from aquatic media. https://app.cochat.ai/papers/10.1039/c3ay40817e
The paper
Bagheri, H., Dehghan, M., Es'haghi, A., & Naderi, M. (2013). A conically fixed position single drop microextraction method for isolation of aryloxyphenoxypropionate herbicides from aquatic media. Analytical Methods. https://doi.org/10.1039/c3ay40817e

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.