The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A near-infrared fluorescent probe for selective detection of HClO based on Se-sensitized aggregation of heptamethine cyanine dye
Abstract
A Se-containing heptamethine cyanine dye based fluorescent probe was successfully developed and used for HClO detection with rapid response and high selectivity based on aggregation behavior. The probe could react with HClO with significant change in its fluorescence profile, which makes it practical for detecting HClO in fetal bovine serum and in living mice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pattison, D. I., & Davies, M. J. (2001) · Chemical Research in Toxicology · doi:10.1021/tx0155451 · Cited by 790
Chen, X., Lee, K.-A., Ha, E.-M., Lee, K. M., Seo, Y. Y., Choi, H. K., Kim, H. N., Kim, M. J., Cho, C.-S., Lee, S. Y., et al. (2011) · Chemical Communications · doi:10.1039/c1cc10589b · Cited by 246
Cited by
Chen, X., Wang, F., Hyun, J. Y., Wei, T., Qiang, J., Ren, X., Shin, I., & Yoon, J. (2016) · Chem. Soc. Rev. · doi:10.1039/c6cs00192k · Cited by 1,166
Recent Development of Chemosensors Based on Cyanine Platforms
Sun, W., Guo, S., Hu, C., Fan, J., & Peng, X. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00001 · Cited by 1,109
Self-citationYuan, L., Wang, L., Agrawalla, B. K., Park, S.-J., Zhu, H., Sivaraman, B., Peng, J., Xu, Q.-H., & Chang, Y.-T. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b00042 · Cited by 558
Li, H., Kim, H., Xu, F., Han, J., Yao, Q., Wang, J., Pu, K., Peng, X., & Yoon, J. (2022) · Chemical Society Reviews · doi:10.1039/d1cs00307k · Cited by 509
Self-citationWu, D., Chen, L., Xu, Q., Chen, X., & Yoon, J. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.9b00307 · Cited by 387
Photostable Ratiometric Pdot Probe for in Vitro and in Vivo Imaging of Hypochlorous Acid
Wu, L., Wu, I.-C., DuFort, C. C., Carlson, M. A., Wu, X., Chen, L., Kuo, C.-T., Qin, Y., Yu, J., Hingorani, S. R., et al. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.7b01545 · Cited by 349
Bioanalytical methods for hypochlorous acid detection: Recent advances and challenges
Zhang, R., Song, B., & Yuan, J. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.11.015 · Cited by 274
Recent progress in the development of fluorescent probes for the detection of hypochlorous acid
Zhang, Y.-R., Liu, Y., Feng, X., & Zhao, B.-X. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.08.066 · Cited by 264
Metadata
- Authors
- Cheng, G., Fan, J., Sun, W., Cao, J., Hu, C., & Peng, X.
- Venue
- Chem. Commun.
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014
- Volume
- 50
- Issue
- 8
- Pages
- 1018-1020
- ISSN
- 1359-7345 (ISSN-L)
- 1364-548X
- OpenAlex
- W2059064215
- Cited by
- 218
- References
- 2
- FWCI
- 7.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.