SU-8 based microprobes for simultaneous neural depth recording and drug delivery in the brain
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
While novel influential concepts in neuroscience bring the focus to local activities generated within a few tens of cubic micrometers in the brain, we are still devoid of appropriate tools to record and manipulate pharmacologically neuronal activity at this fine scale. Here we designed, fabricated and encapsulated microprobes for simultaneous depth recording and drug delivery using exclusively the polymer SU-8 as structural material. A tetrode- and linear-like electrode patterning was combined for the first time with single and double fluidic microchannels for independent drug delivery. The device was tested experimentally using the in vivo anesthetized rat preparation. Both probe types successfully recorded detailed spatiotemporal features of local field potentials and single-cell activity at a resolution never attained before with integrated fluidic probes. Drug delivery was achieved with high spatial and temporal precision in a range from tens of nanoliters to a few microliters, as confirmed histologically. These technological advancements will foster a wide range of neural applications aimed at simultaneous monitoring of brain activity and delivery at a very precise micrometer scale.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Ylinen, A., Bragin, A., Nadasdy, Z., Jando, G., Szabo, I., Sik, A., & Buzsaki, G. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-01-00030.1995 · Cited by 1,092
Neural probe design for reduced tissue encapsulation in CNS
Seymour, J. P., & Kipke, D. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.024 · Cited by 462
Massively Parallel Recording of Unit and Local Field Potentials With Silicon-Based Electrodes
Csicsvari, J., Henze, D. A., Jamieson, B., Harris, K. D., Sirota, A., Barthó, P., Wise, K. D., & Buzsáki, G. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00116.2003 · Cited by 402
Lipid solubility and drug penetration of the blood brain barrier
Oldendorf, W. H. (1974) · Experimental Biology and Medicine · doi:10.3181/00379727-147-38444 · Cited by 373
Subbaroyan, J., Martin, D. C., & Kipke, D. R. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/006 · Cited by 368
Cited by
Next-generation probes, particles, and proteins for neural interfacing
Rivnay, J., Wang, H., Fenno, L., Deisseroth, K., & Malliaras, G. G. (2017) · Science Advances · doi:10.1126/sciadv.1601649 · Cited by 514
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
“Additionally, Altuna et al were able to record multi-unit activity as well as local field potentials (LFPs) using an SU-8 based microelectrode [215].”
MethodRecent advances of controlled drug delivery using microfluidic platforms
Sanjay, S. T., Zhou, W., Dou, M., Tavakoli, H., Ma, L., Xu, F., & Li, X. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2017.09.013 · Cited by 365
Thermally drawn advanced functional fibers: New frontier of flexible electronics
Yan, W., Dong, C., Xiang, Y., Jiang, S., Leber, A., Loke, G., Xu, W., Hou, C., Zhou, S., Chen, M., et al. (2020) · Materials Today · doi:10.1016/j.mattod.2019.11.006 · Cited by 263
A review on mechanical considerations for chronically-implanted neural probes
Lecomte, A., Descamps, E., & Bergaud, C. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8b4f · Cited by 205
“All rights reserved), SU-8 (reproduced from [42] with permission of The Royal Society of Chemistry.”
Background
Metadata
- Authors
- Altuna, A., Bellistri, E., Cid, E., Aivar, P., Gal, B., Berganzo, J., Gabriel, G., Guimerà, A., Villa, R., Fernández, L. J., & Menendez de la Prida, L.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 13
- Issue
- 7
- Pages
- 1422
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2137980274
- Cited by
- 129
- References
- 6
- FWCI
- 5.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: SU-8 based microprobes for simultaneous neural depth recording and drug delivery in the brain. https://app.cochat.ai/papers/10.1039/c3lc41364k
- The paper
- Altuna, A., Bellistri, E., Cid, E., Aivar, P., Gal, B., Berganzo, J., Gabriel, G., Guimerà, A., Villa, R., Fernández, L. J., & Menendez de la Prida, L. (2013). SU-8 based microprobes for simultaneous neural depth recording and drug delivery in the brain. Lab on a Chip. https://doi.org/10.1039/c3lc41364k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.