CoChat

A microfluidic reciprocating intracochlear drug delivery system with reservoir and active dose control

Open access
Kim, Ernest S., Gustenhoven, Erich, Mescher, Mark J., Leary Pararas, Erin E., Smith, Kim A., Spencer, Abigail J., Tandon, Vishal, Borenstein, Jeffrey T., Fiering, Jason · 2014 · Lab Chip
Cited by 48

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Reciprocating microfluidic drug delivery, as compared to steady or pulsed infusion, has unique features which may be advantageous in many therapeutic applications. We have previously described a device, designed for wearable use in small animal models, that periodically infuses and then withdraws a sub-microliter volume of drug solution to and from the endogenous fluid of the inner ear. This delivery approach results in zero net volume of liquid transfer while enabling mass transport of compounds to the cochlea by means of diffusion and mixing. We report here on an advanced wearable delivery system aimed at further miniaturization and complex dosing protocols. Enhancements to the system include the incorporation of a planar micropump to generate reciprocating flow and a novel drug reservoir that maintains zero net volume delivery and permits programmable modulation of the drug concentration in the infused bolus. The reciprocating pump is fabricated from laminated polymer films and employs a miniature electromagnetic actuator to meet the size and weight requirements of a head-mounted in vivo guinea pig testing system. The reservoir comprises a long microchannel in series with a micropump, connected in parallel with the reciprocating flow network. We characterized in vitro the response and repeatability of the planar pump and compared the results with a lumped element simulation. We also characterized the performance of the reservoir, including repeatability of dosing and range of dose modulation. Acute in vivo experiments were performed in which the reciprocating pump was used to deliver a test compound to the cochlea of anesthetized guinea pigs to evaluate short-term safety and efficacy of the system. These advances are key steps toward realization of an implantable device for long-term therapeutic applications in humans.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c3lc51105g

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 48

Metadata

Authors
Kim, E. S., Gustenhoven, E., Mescher, M. J., Leary Pararas, E. E., Smith, K. A., Spencer, A. J., Tandon, V., Borenstein, J. T., & Fiering, J.
Venue
Lab Chip
Published
2014
Volume
14
Issue
4
Pages
710-721
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2097921662
Cited by
48
References
1
FWCI
1.95
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A microfluidic reciprocating intracochlear drug delivery system with reservoir and active dose control. https://app.cochat.ai/papers/10.1039/c3lc51105g
The paper
Kim, E. S., Gustenhoven, E., Mescher, M. J., Leary Pararas, E. E., Smith, K. A., Spencer, A. J., Tandon, V., Borenstein, J. T., & Fiering, J. (2014). A microfluidic reciprocating intracochlear drug delivery system with reservoir and active dose control. Lab Chip. https://doi.org/10.1039/c3lc51105g

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.