Microfluidic single-cell analysis for systems immunology
The DOI matches its Crossref record; 100 of the 100 references it cites were found in a registry or an index.
Abstract
The immune system constantly battles infection and tissue damage, but exaggerated immune responses lead to allergies, autoimmunity and cancer. Discrimination of self from foreign and the fine-tuning of immunity are achieved by information processing pathways, whose regulatory mechanisms are little understood. Cell-to-cell variability and stochastic molecular interactions result in diverse cellular responses to identical signaling inputs, casting doubt on the reliability of traditional population-averaged analyses. Furthermore, dynamic molecular and cellular interactions create emergent properties that change over multiple time scales. Understanding immunity in the face of complexity and noisy dynamics requires time-dependent analysis of single-cells in a proper context. Microfluidic systems create precisely defined microenvironments by controlling fluidic and surface chemistries, feature sizes, geometries and signal input timing, and thus enable quantitative multi-parameter analysis of single cells. Such qualities allow observable dynamic environments approaching in vivo levels of biological complexity. Seamless parallelization of functional units in microfluidic devices allows high-throughput measurements, an essential feature for statistically meaningful analysis of naturally variable biological systems. These abilities recapitulate diverse scenarios such as cell-cell signaling, migration, differentiation, antibody and cytokine production, clonal selection, and cell lysis, thereby enabling accurate and meaningful study of immune behaviors in vitro.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Finally, immune cells are highly mobile and high resolution time-lapse imaging facilitated in microfluidic models is an important advantage for analyzing their dynamics in real-time[45].”
From Microfluidics: A New Tool for Modeling Cancer–Immune Interactions (2016) · cites this paper as [45]
In the citing paper
“Although these devices have better potential for high throughput testing than animal studies, many current microfluidic platforms depend heavily on high resolution imaging and similarly time-consuming image and data analysis[45].”
From Microfluidics: A New Tool for Modeling Cancer–Immune Interactions (2016) · cites this paper as [45]
Citations
Cites
Stochastic Gene Expression in a Single Cell
Elowitz, M. B., Levine, A. J., Siggia, E. D., & Swain, P. S. (2002) · Science · doi:10.1126/science.1070919 · Cited by 5,441
Clapham, D. E. (2007) · Cell · doi:10.1016/j.cell.2007.11.028 · Cited by 4,175
Genomic responses in mouse models poorly mimic human inflammatory diseases
Seok, J., Warren, H. S., Cuenca, A. G., Mindrinos, M. N., Baker, H. V., Xu, W., Richards, D. R., McDonald-Smith, G. P., Gao, H., Hennessy, L., et al. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1222878110 · Cited by 3,005
Secretory products of macrophages.
Nathan, C. F. (1987) · Journal of Clinical Investigation · doi:10.1172/jci112815 · Cited by 2,615
Functional roles for noise in genetic circuits
Eldar, A., & Elowitz, M. B. (2010) · Nature · doi:10.1038/nature09326 · Cited by 1,480
Droplet microfluidic technology for single-cell high-throughput screening
Brouzes, E., Medkova, M., Savenelli, N., Marran, D., Twardowski, M., Hutchison, J. B., Rothberg, J. M., Link, D. R., Perrimon, N., & Samuels, M. L. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0903542106 · Cited by 1,069
Dynamics of the p53-Mdm2 feedback loop in individual cells
Lahav, G., Rosenfeld, N., Sigal, A., Geva-Zatorsky, N., Levine, A. J., Elowitz, M. B., & Alon, U. (2004) · Nature Genetics · doi:10.1038/ng1293 · Cited by 1,013
Single-cell NF-κB dynamics reveal digital activation and analogue information processing
Tay, S., Hughey, J. J., Lee, T. K., Lipniacki, T., Quake, S. R., & Covert, M. W. (2010) · Nature · doi:10.1038/nature09145 · Cited by 789
Self-citationHydrodynamic stretching of single cells for large population mechanical phenotyping
Gossett, D. R., Tse, H. T. K., Lee, S. A., Ying, Y., Lindgren, A. G., Yang, O. O., Rao, J., Clark, A. T., & Di Carlo, D. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1200107109 · Cited by 775
Quantitative assessment of single-cell RNA-sequencing methods
Wu, A. R., Neff, N. F., Kalisky, T., Dalerba, P., Treutlein, B., Rothenberg, M. E., Mburu, F. M., Mantalas, G. L., Sim, S., Clarke, M. F., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2694 · Cited by 696
Cited by
Single-cell barcoding and sequencing using droplet microfluidics
Zilionis, R., Nainys, J., Veres, A., Savova, V., Zemmour, D., Klein, A. M., & Mazutis, L. (2017) · Nature Protocols · doi:10.1038/nprot.2016.154 · Cited by 727
Droplet microfluidics for microbiology: techniques, applications and challenges
Kaminski, T. S., Scheler, O., & Garstecki, P. (2016) · Lab on a Chip · doi:10.1039/c6lc00367b · Cited by 424
Shembekar, N., Chaipan, C., Utharala, R., & Merten, C. A. (2016) · Lab on a Chip · doi:10.1039/c6lc00249h · Cited by 372
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Microfluidics: A New Tool for Modeling Cancer–Immune Interactions
Boussommier-Calleja, A., Li, R., Chen, M. B., Wong, S. C., & Kamm, R. D. (2016) · Trends in Cancer · doi:10.1016/j.trecan.2015.12.003 · Cited by 224
“Although these devices have better potential for high throughput testing than animal studies, many current microfluidic platforms depend heavily on high resolution imaging and similarly time-consuming image and data analysis[45].”
BackgroundMethodInfluentialNoise Facilitates Transcriptional Control under Dynamic Inputs
Kellogg, R. A., & Tay, S. (2015) · Cell · doi:10.1016/j.cell.2015.01.013 · Cited by 213
Self-citationParlato, S., De Ninno, A., Molfetta, R., Toschi, E., Salerno, D., Mencattini, A., Romagnoli, G., Fragale, A., Roccazzello, L., Buoncervello, M., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-01013-x · Cited by 181
High-Throughput Secretomic Analysis of Single Cells to Assess Functional Cellular Heterogeneity
Lu, Y., Chen, J. J., Mu, L., Xue, Q., Wu, Y., Wu, P.-H., Li, J., Vortmeyer, A. O., Miller-Jensen, K., Wirtz, D., et al. (2013) · Analytical Chemistry · doi:10.1021/ac400082e · Cited by 173
The effects of monocytes on tumor cell extravasation in a 3D vascularized microfluidic model
Boussommier-Calleja, A., Atiyas, Y., Haase, K., Headley, M., Lewis, C., & Kamm, R. D. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2018.03.005 · Cited by 158
High-Content Quantification of Single-Cell Immune Dynamics
Junkin, M., Kaestli, A. J., Zhang, C., Jordi, C., Albayrak, C., Hoffmann, A., & Tay, S. (2016) · Cell Reports · doi:10.1016/j.celrep.2016.03.033 · Cited by 146
Self-citationBarata, D. B., van Blitterswijk, C., & Habibović, P. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.09.009 · Cited by 128
Digital microfluidic immunocytochemistry in single cells
Ng, A. H. C., Chamberlain, M. D., Situ, H., Lee, V., & Wheeler, A. R. (2015) · Nature Communications · doi:10.1038/ncomms8513 · Cited by 136
High-throughput microfluidic single-cell analysis pipeline for studies of signaling dynamics
Kellogg, R., Gómez-Sjöberg, R., Leyrat, A. A., & Tay, S. (2014) · Nature Protocols · doi:10.1038/nprot.2014.120 · Cited by 120
Self-citationSingle-cell metabolomics by mass spectrometry: Advances, challenges, and future applications
Ali, A., Abouleila, Y., Shimizu, Y., Hiyama, E., Emara, S., Mashaghi, A., & Hankemeier, T. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.02.033 · Cited by 111
Mixing Enhancement in Serpentine Micromixers with a Non-Rectangular Cross-Section
Clark, J., Kaufman, M., & Fodor, P. S. (2018) · Micromachines · doi:10.3390/mi9030107 · Cited by 99
Utilizing population variation, vaccination, and systems biology to study human immunology
Tsang, J. S. (2015) · Trends in Immunology · doi:10.1016/j.it.2015.06.005 · Cited by 101
Recent Advances in Droplet-based Microfluidic Technologies for Biochemistry and Molecular Biology
Barea, J. S., Lee, J., & Kang, D. (2019) · Micromachines · doi:10.3390/mi10060412 · Cited by 99
How single-cell immunology is benefiting from microfluidic technologies
Jammes, F., & Maerkl, S. J. (2020) · Microsystems & Nanoengineering · doi:10.1038/s41378-020-0140-8 · Cited by 79
Digital signaling decouples activation probability and population heterogeneity
Kellogg, R., Tian, C., Lipniacki, T., Quake, S. R., & Tay, S. (2015) · eLife · doi:10.7554/elife.08931 · Cited by 74
Self-citationFluorescent analysis of bioactive molecules in single cells based on microfluidic chips
Fan, Y., Dong, D., Li, Q., Si, H., Pei, H., Lu, L., & Tang, B. (2018) · Lab on a Chip · doi:10.1039/c7lc01333g · Cited by 73
Integrating Immunology and Microfluidics for Single Immune Cell Analysis
Sinha, N., Subedi, N., & Tel, J. (2018) · Frontiers in Immunology · doi:10.3389/fimmu.2018.02373 · Cited by 76
Bridging the gap: microfluidic devices for short and long distance cell–cell communication
Vu, T. Q., de Castro, R. M. B., & Qin, L. (2017) · Lab on a Chip · doi:10.1039/c6lc01367h · Cited by 63
Single-Cell Omics Analyses Enabled by Microchip Technologies
Deng, Y., Finck, A., & Fan, R. (2019) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-060418-052538 · Cited by 68
Microfluidic technologies in cell isolation and analysis for biomedical applications
Wu, J., Chen, Q., & Lin, J. (2016) · The Analyst · doi:10.1039/c6an01939k · Cited by 65
Microfluidic Devices for Drug Assays
Regnault, C., Dheeman, D. S., & Hochstetter, A. (2018) · Microarrays · doi:10.3390/ht7020018 · Cited by 62
Label-Free Multivariate Biophysical Phenotyping-Activated Acoustic Sorting at the Single-Cell Level
Li, P., & Ai, Y. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c05352 · Cited by 58
Droplets microfluidics platform—A tool for single cell research
Li, B., Ma, X., Cheng, J., Tian, T., Guo, J., Wang, Y., & Pang, L. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1121870 · Cited by 54
Gopalakrishnan, N., Hannam, R., Casoni, G. P., Barriet, D., Ribe, J. M., Haug, M., & Halaas, Ø. (2015) · Lab on a Chip · doi:10.1039/c4lc01438c · Cited by 42
In vitro micro-physiological models for translational immunology
Ramadan, Q., & Gijs, M. A. M. (2015) · Lab on a Chip · doi:10.1039/c4lc01271b · Cited by 41
T Cell Dynamic Activation and Functional Analysis in Nanoliter Droplet Microarray
Sarkar, S. (2015) · Journal of Clinical & Cellular Immunology · doi:10.4172/2155-9899.1000334 · Cited by 41
Engineering of synthetic cellular microenvironments: Implications for immunity
Adutler-Lieber, S., Zaretsky, I., Platzman, I., Deeg, J., Friedman, N., Spatz, J. P., & Geiger, B. (2014) · Journal of Autoimmunity · doi:10.1016/j.jaut.2014.05.003 · Cited by 39
Dang, B. V., & Kim, S. (2016) · Lab on a Chip · doi:10.1039/c6lc00911e · Cited by 34
Microfluidics-based single cell analysis reveals drug-dependent motility changes in trypanosomes
Hochstetter, A., Stellamanns, E., Deshpande, S., Uppaluri, S., Engstler, M., & Pfohl, T. (2015) · Lab on a Chip · doi:10.1039/c5lc00124b · Cited by 31
Surrati, A., Linforth, R., Fisk, I. D., Sottile, V., & Kim, D. (2016) · The Analyst · doi:10.1039/c6an00170j · Cited by 32
Hematopoietic stem cell lineage specification
Pouzolles, M., Oburoglu, L., Taylor, N. N., & Zimmermann, V. S. (2016) · Current Opinion in Hematology · doi:10.1097/moh.0000000000000260 · Cited by 41
Microfluidic three-dimensional cell culture of stem cells for high-throughput analysis
Kim, J. A., Hong, S., & Rhee, W. J. (2019) · World Journal of Stem Cells · doi:10.4252/wjsc.v11.i10.803 · Cited by 36
Wartmann, D., Rothbauer, M., Kuten, O., Barresi, C., Visús, C., Felzmann, T., & Ertl, P. (2015) · Frontiers in Materials · doi:10.3389/fmats.2015.00060 · Cited by 34
Moghaddam, F. D., Anvar, A., Ilkhani, E., Dadgar, D., Rafiee, M., Ranjbaran, N., Mortazavi, P., Ghoreishian, S. M., Huh, Y. S., & Makvandi, P. (2025) · Molecular Cancer · doi:10.1186/s12943-025-02479-4 · Cited by 44
Automated Microfluidic System for Dynamic Stimulation and Tracking of Single Cells
Dettinger, P., Frank, T., Etzrodt, M., Ahmed, N., Reimann, A., Trenzinger, C., Loeffler, D., Kokkaliaris, K. D., Schroeder, T., & Tay, S. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00312 · Cited by 37
Self-citationMicrofluidic Cell Trapping for Single-Cell Analysis
Deng, B., Wang, H., Tan, Z., & Quan, Y. (2019) · Micromachines · doi:10.3390/mi10060409 · Cited by 30
Hamon, C., Henriksen‐Lacey, M., Porta, A. L., Rosique, M., Langer, J., Scarabelli, L., Serrano-Montes, A. B., González‐Rubio, G., de Pancorbo, M. M., Liz‐Marzán, L. M., et al. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201602225 · Cited by 29
Characterisation of anticancer peptides at the single-cell level
Armbrecht, L., Gabernet, G., Kurth, F., Hiss, J. A., Schneider, G., & Dittrich, P. S. (2017) · Lab on a Chip · doi:10.1039/c7lc00505a · Cited by 30
Silva, K. D., Kumar, P., & Choonara, Y. E. (2025) · Wound Repair and Regeneration · doi:10.1111/wrr.13251 · Cited by 34
High spatial and temporal resolution cell manipulation techniques in microchannels
Novo, P., Dell’Aica, M., Janasek, D., & Zahedi, R. P. (2016) · The Analyst · doi:10.1039/c6an00027d · Cited by 27
Development of Microfluidic Systems Enabling High-Throughput Single-Cell Protein Characterization
Fan, B., Li, X., Chen, D., Peng, H., Wang, J., & Chen, J. (2016) · Sensors · doi:10.3390/s16020232 · Cited by 25
Time-resolved microwell cell-pairing array reveals multiple T cell activation profiles
Desalvo, A., Bateman, F., James, E., Morgan, H., & Elliott, T. J. (2020) · Lab on a Chip · doi:10.1039/d0lc00628a · Cited by 25
Grigolato, F., Egholm, C., Impellizzieri, D., Arosio, P., & Boyman, O. (2020) · Allergy · doi:10.1111/all.14195 · Cited by 21
Systems Biology and immune aging
O’Connor, J., Herrera, G., Martínez‐Romero, A., de Oyanguren, F. S., Díaz, L., Carvalho‐Gomes, Â., Balaguer, S., & Callaghan, R. C. (2014) · Immunology Letters · doi:10.1016/j.imlet.2014.09.009 · Cited by 26
Sullivan, M. R., Ugolini, G. S., Sarkar, S., Kang, W., Smith, E. C., McKenney, S., & Konry, T. (2020) · Cell Death and Disease · doi:10.1038/s41419-020-03173-7 · Cited by 26
Numerical Simulations of the Digital Microfluidic Manipulation of Single Microparticles
Lan, C., Pal, S., Li, Z., & Ma, Y. (2015) · Langmuir · doi:10.1021/acs.langmuir.5b02011 · Cited by 19
Lab-on-a-chip workshop activities for secondary school students
Esfahani, M. M., Tarn, M. D., Choudhury, T. A., Hewitt, L. C., Mayo, A. J., Rubin, T. A., Waller, M. R., Christensen, M. G., Dawson, A., & Pamme, N. (2016) · Biomicrofluidics · doi:10.1063/1.4940884 · Cited by 19
Real-time assessment of nanoparticle-mediated antigen delivery and cell response
Cunha-Matos, C. A., Millington, O. R., Wark, A. W., & Zagnoni, M. (2016) · Lab on a Chip · doi:10.1039/c6lc00599c · Cited by 21
Challenges of Decoding Transcription Factor Dynamics in Terms of Gene Regulation
Martin, E. W., & Sung, M. (2018) · Cells · doi:10.3390/cells7090132 · Cited by 16
Gholizadeh, A., Abbaslou, S., Xie, P., Knaian, A. N., & Javanmard, M. (2019) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2019.06.037 · Cited by 17
Microfluidic Bioreactors for Cellular Microarrays
Willaert, R., & Goossens, K. V. Y. (2015) · Fermentation · doi:10.3390/fermentation1010038 · Cited by 17
Kaji, N., & Baba, Y. (2014) · Analytical Sciences · doi:10.2116/analsci.30.859 · Cited by 16
Feng, J., Fohlerová, Z., Liu, X., Chang, H., & Neužil, P. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.04.179 · Cited by 16
Subedi, N., Verhagen, L. P., de Jonge, P. K. J. D., Eyndhoven, L. C. V., van Turnhout, M. C., Koomen, V., Baudry, J., Eyer, K., Dolstra, H., & Tel, J. (2022) · Advanced Biology · doi:10.1002/adbi.202200207 · Cited by 15
Efficient AC electrothermal flow (ACET) on-chip for enhanced immunoassays
Draz, M. S., Uning, K. T., Dupouy, D., & Gijs, M. A. M. (2023) · Lab on a Chip · doi:10.1039/d2lc01147f · Cited by 15
Microtissue size and cell-cell communication modulate cell migration in arrayed 3D collagen gels
Nuhn, J. A. M., Gong, S., Che, X., Que, L., & Schneider, I. C. (2018) · Biomedical Microdevices · doi:10.1007/s10544-018-0309-1 · Cited by 12
The emerging role of nanomaterials in immunological sensing — a brief review
Corrie, S. R., & Plebanski, M. (2018) · Molecular Immunology · doi:10.1016/j.molimm.2017.12.017 · Cited by 13
Microfluidic techniques for tumor cell detection
Tan, F., Wang, T., Wang, H., & Zheng, Y. (2018) · Electrophoresis · doi:10.1002/elps.201800413 · Cited by 11
Emerging roles of mechanically activated ion channels in autoimmune disease
Zeng, Z., Chen, E., & Xue, J. (2025) · Autoimmunity Reviews · doi:10.1016/j.autrev.2025.103813 · Cited by 10
Microfabricated tools for quantitative plant biology
Elitaş, M., Yüce, M., & Budak, H. (2017) · The Analyst · doi:10.1039/c6an02643e · Cited by 9
Yi, S., Liu, X., Huo, Y., Li, X., Tang, Y., & Li, J. (2023) · Journal of the Science of Food and Agriculture · doi:10.1002/jsfa.12520 · Cited by 8
Okochi, M., Koike, S., Tanaka, M., & Honda, H. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.11.013 · Cited by 9
Assessment of chimeric antigen receptor T cytotoxicity by droplet microfluidics in vitro
Wong, K. U., Shi, J., Li, P., Wang, H., Jia, Y., Deng, C., Jiang, L., & Wong, A. H. (2022) · Antibody Therapeutics · doi:10.1093/abt/tbac008 · Cited by 10
Suzuki, M., Minakuchi, Y., Mizutani, F., & Yasukawa, T. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112892 · Cited by 7
Yang, H., Sinha, N., Rand, U., Häuser, H., Köster, M., de Greef, T. F. A., & Tel, J. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114353 · Cited by 5
Topology, dynamics, and heterogeneity in immune signaling
Webb, J. T., & Behar, M. (2015) · WIREs Systems Biology and Medicine · doi:10.1002/wsbm.1306 · Cited by 5
Ezzat, H. S., Faris, R. A., & Taha, M. (2024) · AIP conference proceedings · doi:10.1063/5.0191751 · Cited by 4
Principal component-based image segmentation: a new approach to outline in vitro cell colonies
Arous, D., Schrunner, S., Hanson, I., Edin, N. F. J., & Malinen, E. (2022) · Computer Methods in Biomechanics and Biomedical Engineering Imaging & Visualization · doi:10.1080/21681163.2022.2035822 · Cited by 8
In Vitro Biosensing Using Micro-/Nanomachines
Gao, J., Yuan, K., & Zhang, L. (2021) · Springer eBooks · doi:10.1007/978-3-030-80197-7_10 · Cited by 4
Choi, H., Choi, N., Lim, B., Kim, T., Song, S., & Kim, Y. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.05.047 · Cited by 4
Multiplexed profiling of single-cell secretion on a hierarchical loading microwell chip
Shao, N., Zhou, Y., & Liu, X. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.117711 · Cited by 3
Single-cell omics: moving towards a new era in ischemic stroke research
Zeng, J., Zhou, H., Wan, H., & Yang, J. (2025) · European Journal of Pharmacology · doi:10.1016/j.ejphar.2025.177725 · Cited by 3
Cell-Based Immuno-Biosensors Using Microfluidics
Pugner, B., Petersson, E., Ahmed, S., Mustafa, M., Okoh, J., & Qiang, Y. (2026) · Sensors · doi:10.3390/s26061970 · Cited by 2
Single-cell screening using microfluidic systems
Nainys, J., Milkus, V., & Mažutis, L. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-812659-2.00013-2 · Cited by 2
Microfluidics: A New Tool for Modeling Cancer-Immune
Boussommier-Calleja, I., Li, R., Chen, M. B., & Kamm, R. D. (2016) · Cited by 2
Orthogonal-electrode digital microfluidics for high-throughput droplet manipulations
Wang, Y. B., Guo, Z., Lin, X., Shen, R., Liu, Y., Tsoi, C. C., Mak, P., Martins, R. P., Zhang, X., & Jia, Y. (2025) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2025.139303 · Cited by 1
Label-free single cell analysis in microfluidics using digital holographic microscopy
Bansode, V., Espulgar, W., & Saito, M. (2025) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ae2dac · Cited by 1
Single Cell Interrogation using Optofluidic Platforms for Systems Immunology
Aksu, S. (2016) · MRS Advances · doi:10.1557/adv.2016.337 · Cited by 1
WITHDRAWN: Systems Biology and Immune Aging
O’Connor, J., Herrera, G., Martínez‐Romero, A., de Oyanguren, F. S., Díaz, L., Carvalho‐Gomes, Â., Balaguer, S., & Callaghan, R. C. (2014) · Immunology Letters · doi:10.1016/j.imlet.2014.09.008 · Cited by 1
In vitro cytokine expression analysis by droplet microfluidicsPreprint
Wong, A. H., Akıncılar, S. C., Chua, J. Y. H., Morgan, D., Hei, D., & Tergaonkar, V. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.12.28.474355 · Cited by 3
Sullivan, M. R. (2023) · Digital Repository Service (Northeastern University) · doi:10.17760/d20531812 · Cited by 1
Single-Cell Interrogation of the Immune System Using Microtools
Albayrak, C., & Tay, S. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-394447-4.30101-8
Self-citationMehrabi, M. R., Soleimani, M., Abroun, S., Vasei, M., & Naser‐Moghadasi, M. (2014) · Majallah-i dānishgāh-i ̒ulūm-i pizishkī-i Māzandarān/Journal of Mazandaran University of Medical Sciences
Microfluidic devices for mechanical characterization and manipulation of monocytes
Ravetto, A. A. (2015) · TU/e Research Portal · doi:10.6100/ir789319
Microfluidic Probes for Single-Cell Proteomic Analysis
Sarkar, A., Wu, L., & Han, J. (2018) · Wiley-VCH eBooks · doi:10.1002/9783527696789.ch11
Johnson, J. L., Anderson, E. A., Klukas, E., Chan, C., Hanson, R. N., Sinyigaya, P., & Tong, R. (2019) · AIP conference proceedings · doi:10.1063/1.5110159
Kim, K.-Y., A., M., & Afzal, A. (2018) · MDPI eBooks · doi:10.3390/books978-3-03897-008-8
A Device for Isolation of Selected Single Adherent Cells
Dai, W.-Y., Guo, J.-B., Chen, X. X., & Luo, Z. (2022) · BioMed Research International · doi:10.1155/2022/4303586
Single-Cell Interrogation of the Immune System Using Microtools
Albayrak, C., & Tay, S. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-821618-7.30101-8
Self-citationبناء جهاز موائع جزيئي متكامل حساس ومنخفض التكلفة وسريع مع مضخة حقن لتحليل الإيبوبروفين
Sakin, H., & Faris, R. A. (2023) · Iraqi Journal of Laser · doi:10.31900/ijl.v22i1.370
Yu, H., Chen, X., Zhang, Y., Yang, S., Gui, L., Chen, D., Wang, J., Chen, J., & Wang, K. (2023) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors56945.2023.10325173
Metadata
- Authors
- Junkin, M., & Tay, S.
- Affiliations
- ETH Zurich (CH)
- Corresponding author
- Tay, Savaş
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014
- Volume
- 14
- Issue
- 7
- Pages
- 1246
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2112667541
- Cited by
- 96
- References
- 100
- Citations by year
- 2026: 1 · 2025: 7 · 2024: 1 · 2023: 6 · 2022: 5 · 2021: 3 · 2020: 5 · 2019: 7 · 2018: 15 · 2017: 5 · 2016: 18 · 2015: 15 · 2014: 7
- FWCI
- 1.28
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Keywords
- microfluidics, single-cell analysis, systems immunology, cell-to-cell variability, stochastic gene expression, cell-to-cell communication, immune regulation, clonal selection, antibody production, cytokine production, cell migration, cell differentiation, cell lysis
- MeSH terms
- Allergy and Immunology, Animals, Humans, Neoplasms, Portraits as Topic, Autoimmunity, Microfluidic Analytical Techniques, Systems Biology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.