Cited by 156Characterization and Applications of Magnetic NanoparticlesAdvanced MRI Techniques and ApplicationsMagnetic Properties and Synthesis of Ferrites

The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.

Scaling laws at the nanosize: the effect of particle size and shape on the magnetism and relaxivity of iron oxide nanoparticle contrast agents

Open access

Abstract

The magnetic properties of iron oxide nanoparticles govern their relaxivities and efficacy as contrast agents for MRI. These properties are in turn determined by their composition, size and morphology. Herein we present a systematic study of the effect of particle size and shape of magnetite nanocrystals synthesized by thermal decomposition of iron salts on both their magnetism and longitudinal and transverse relaxivities, r1 and r2, respectively. Faceted nanoparticles demonstrate superior magnetism and relaxivities to spherical nanoparticles of similar size. For faceted nanoparticles, but not for spherical ones, r1 and r2 further increase with increasing particle size up to a size of 18 nm. This observation is in accordance with increasing saturation magnetization for nanoparticles increasing in size up to 12 nm, above which a plateau is observed. The NMRD (Nuclear Magnetic Resonance Dispersion) profiles of MIONs (Magnetic Iron Oxide Nanoparticles) display an increase in longitudinal relaxivity with decreasing magnetic field strength with a plateau below 1 MHz. The transverse relaxivity shows no dependence on the magnetic field strength between 20 MHz and 500 MHz. These observations translate to phantom MR images: in T1-weighted SWIFT (SWeep Imaging with Fourier Transform) images MIONs have a positive contrast with little dependence on the particle size, whereas in T2-weighted gradient-echo images MIONs create a negative contrast which increases in magnitude with increasing particle size. Altogether, these results will enable the development of particulate MRI contrast agents with enhanced efficacy for biomedical and clinical applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c3tb00369h

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. Silva, 2011, Int. J. Nanomed., 6, 591

Cited by

Sorted by citations

See all 156

Metadata

Authors
Smolensky, E. D., Park, H.-Y. E., Zhou, Y., Rolla, G. A., Marjańska, M., Botta, M., & Pierre, V. C.
Affiliations
  • University of Minnesota (US)
  • Università degli Studi del Piemonte Orientale “Amedeo Avogadro” (IT)
Corresponding author
Pierre, Valérie C.
Venue
Journal of Materials Chemistry B
Published
2013
Volume
1
Issue
22
Pages
2818
ISSN
  • 2050-750X (ISSN-L)
  • 2050-7518
OpenAlex
W1993475836
Cited by
156
References
42
Citations by year
2026: 11 · 2025: 13 · 2024: 13 · 2023: 12 · 2022: 11 · 2021: 14 · 2020: 12 · 2019: 12 · 2018: 13 · 2017: 7 · 2016: 9 · 2015: 14 · 2014: 11 · 2013: 4
FWCI
6.98
Type
journal article
Language
en
Open access
Locations
  • Journal of Materials Chemistry B (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • National Science Foundation
  • W. M. Keck Foundation
  • University of Pennsylvania
  • Regione Piemonte
  • National Institutes of Health
  • College of Science and Engineering, University of Minnesota
  • Materials Research Science and Engineering Center, Harvard University
  • Earth Sciences Division
  • National Institute of General Medical Sciences (T32GM008700)
  • National Institute of Biomedical Imaging and Bioengineering (P41EB015894)
  • National Center for Research Resources (P41RR008079)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Physical Sciences › Materials Science › Materials Chemistry › Magnetic Properties and Synthesis of Ferrites
Keywords
iron oxide nanoparticles, MRI contrast agents, relaxivity, particle size effects, particle shape, faceted nanoparticles, magnetite, saturation magnetization, thermal decomposition synthesis, T1 contrast, T2 contrast, nanoparticle morphology

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review