A spatiotemporally defined in vitro microenvironment for controllable signal delivery and drug screening
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
An in vitro model of mimicking tumor microenvironments to study in vivo -like cancer migration and screening of inhibitors is demonstrated.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Microfluidic assays have been designed to replicate certain aspects of several of these steps, such as EMT[13, 14], cancer cell invasion and adhesion[15–17], and intra-[18, 19] and extravasation[17, 20– 22] (see Text Box 3).”
From Microfluidics: A New Tool for Modeling Cancer–Immune Interactions (2016) · cites this paper as [13]
Citations
Cites
Hallmarks of Cancer: The Next Generation
Hanahan, D., & Weinberg, R. A. (2011) · Cell · doi:10.1016/j.cell.2011.02.013 · Cited by 66,590
Epithelial-Mesenchymal Transitions in Development and Disease
Thiery, J. P., Acloque, H., Huang, R. Y. J., & Nieto, M. A. (2009) · Cell · doi:10.1016/j.cell.2009.11.007 · Cited by 9,931
The Epithelial-Mesenchymal Transition Generates Cells with Properties of Stem Cells
Mani, S. A., Guo, W., Liao, M.-J., Eaton, E. N., Ayyanan, A., Zhou, A. Y., Brooks, M., Reinhard, F., Zhang, C. C., Shipitsin, M., et al. (2008) · Cell · doi:10.1016/j.cell.2008.03.027 · Cited by 8,672
A Perspective on Cancer Cell Metastasis
Chaffer, C. L., & Weinberg, R. A. (2011) · Science · doi:10.1126/science.1203543 · Cited by 4,807
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Modeling Tissue Morphogenesis and Cancer in 3D
Yamada, K. M., & Cukierman, E. (2007) · Cell · doi:10.1016/j.cell.2007.08.006 · Cited by 1,751
Spheroid-based drug screen: Considerations and practical approach
Friedrich, J., Seidel, C., Ebner, R., & Kunz-Schughart, L. A. (2009) · Nature Protocols · doi:10.1038/nprot.2008.226 · Cited by 1,742
In vitro cell migration and invasion assays
Kramer, N., Walzl, A., Unger, C., Rosner, M., Krupitza, G., Hengstschläger, M., & Dolznig, H. (2013) · Mutation Research/Reviews in Mutation Research · doi:10.1016/j.mrrev.2012.08.001 · Cited by 1,170
High-throughput 3D spheroid culture and drug testing using a 384 hanging drop array
Tung, Y.-C., Hsiao, A. Y., Allen, S. G., Torisawa, Y.-S., Ho, M., & Takayama, S. (2011) · The Analyst · doi:10.1039/c0an00609b · Cited by 969
Crossing the endothelial barrier during metastasis
Reymond, N., d'Água, B. B., & Ridley, A. J. (2013) · Nature Reviews Cancer · doi:10.1038/nrc3628 · Cited by 922
Research works printed but not linked: 2
- Zervantonakis, 2012, PNAS, 109, 13515, 10.1073/pnas.1210182109 · DOI · Paper page
- Lee, 2013, Lab. Invest., 1
Cited by
Microfluidic 3D cell culture: from tools to tissue models
van Duinen, V., Trietsch, S. J., Joore, J., Vulto, P., & Hankemeier, T. (2015) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2015.05.002 · Cited by 500
Microfluidics: A New Tool for Modeling Cancer–Immune Interactions
Boussommier-Calleja, A., Li, R., Chen, M. B., Wong, S. C., & Kamm, R. D. (2016) · Trends in Cancer · doi:10.1016/j.trecan.2015.12.003 · Cited by 224
“Note that we show intravasation for a single cancer cell, but future models should also consider intravasation from a multi-cellular tumor mass, as has been done in a non-microfluidic 3D model [23]: i) Spheroid of GFP-MCF-7 labelled cells to model epithelial to mesenchymal transition (EMT), where the dashed circle sho…”
MethodInfluentialTumour-on-a-chip: microfluidic models of tumour morphology, growth and microenvironment
Tsai, H.-F., Trubelja, A., Shen, A. Q., & Bao, G. (2017) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0137 · Cited by 214
Interplay between tumor microenvironment and partial EMT as the driver of tumor progression
Aggarwal, V., Montoya, C. A., Donnenberg, V. S., & Sant, S. (2021) · iScience · doi:10.1016/j.isci.2021.102113 · Cited by 135
Kuo, C.-T., Wang, J.-Y., Lin, Y.-F., Wo, A. M., Chen, B. P. C., & Lee, H. (2017) · Scientific Reports · doi:10.1038/s41598-017-04718-1 · Cited by 107
Self-citationMicrofluidic-based vascularized microphysiological systems
Lee, S., Ko, J., Park, D., Lee, S.-R., Chung, M., Lee, Y., & Jeon, N. L. (2018) · Lab on a Chip · doi:10.1039/c8lc00285a · Cited by 91
Contributions of 3D Cell Cultures for Cancer Research
Ravi, M., Ramesh, A., & Pattabhi, A. (2017) · Journal of Cellular Physiology · doi:10.1002/jcp.25664 · Cited by 88
Rapid Magnetic 3D Printing of Cellular Structures with MCF-7 Cell Inks
Mishriki, S., Fattah, A. R. A., Kammann, T., Sahu, R. P., Geng, F., & Puri, I. K. (2019) · Research · doi:10.34133/2019/9854593 · Cited by 27
Bioreactors and Microfluidics for Osteochondral Interface Maturation
Canadas, R. F., Marques, A. P., Reis, R. L., & Oliveira, J. M. (2018) · Advances in experimental medicine and biology · doi:10.1007/978-3-319-76735-2_18 · Cited by 17
Boussommier-Calleja, A. (2020) · Bioengineering Innovative Solutions for Cancer · doi:10.1016/b978-0-12-813886-1.00013-9 · Cited by 10
Application of microfluidics in cancer treatment
Shahidian, A., Ghassemi, M., Mohammadi, J., & Hashemi, M. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-817809-6.00009-1 · Cited by 6
Microfluidics and Future of Cancer Diagnostics
Jamalian, S., Jafarnejad, M., & Aref, A. R. (2016) · Cancer drug discovery and develogment/Cancer drug discovery and development · doi:10.1007/978-3-319-45397-2_4 · Cited by 4
Kuo, C., Chi, C.-Y., Wu, P., Chuang, F.-T., Lin, Y., Liu, H.-K., Huang, G.-S., Tsai, T.-C., Wo, A. M., Lee, H., et al. (2016) · Journal of Applied Physics · doi:10.1063/1.4939677 · Cited by 4
Self-citationMicrofluidic devices and their applicability to cell studies
Fernandes, A. C., Semenova, D., & Grundtvig, I. P. R. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-822482-3.00003-8 · Cited by 2
A microfluidic device inspired by leaky tumor vessels for hematogenous metastasis mechanism research
Yin, S., Lu, R., Li, Y., Sun, D., Liu, C., Liu, B., & Li, J. (2023) · The Analyst · doi:10.1039/d2an02081e · Cited by 2
Control of Cell Migration Using Optogenetics
Valon, L., & de Beco, S. (2020) · Methods in molecular biology · doi:10.1007/978-1-0716-0779-4_29 · Cited by 1
Kuo, C., Liao, Y., & Lee, H. (2025) · Advanced NanoBiomed Research · doi:10.1002/anbr.202500060 · Cited by 2
Self-citationCell Dynamics in Three-dimensional (3D) Culture Environments
Fan, R. (2017) · RIT Scholar Works (Rochester Institute of Technology)
Metadata
- Authors
- Kuo, C.-T., Liu, H.-K., Huang, G.-S., Chang, C.-H., Chen, C.-L., Chen, K.-C., Yun-Ju Huang, R., Lin, C.-H., Lee, H., Huang, C.-S., & Wo, A. M.
- Affiliations
- National Taiwan University (TW)
- Institute of Applied Mechanics
- Department of Obstetrics & Gynaecology
- National Taiwan University Hospital (TW)
- Corresponding author
- Lee, Hsinyu
- Huang, Chiun-Sheng
- Wo, Andrew M.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014
- Volume
- 139
- Issue
- 19
- Pages
- 4846-4854
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W1969178825
- Cited by
- 20
- References
- 42
- Citations by year
- 2025: 1 · 2023: 2 · 2021: 1 · 2020: 2 · 2019: 3 · 2018: 2 · 2017: 4 · 2016: 4 · 2015: 1
- FWCI
- 1.56
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- The Analyst (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Council
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- tumor microenvironment, microfluidics, 3D cell culture, tumor cell migration, metastasis, drug screening, concentration gradient, tumor spheroids, epithelial-mesenchymal transition, EpCAM, pseudopodia, drug resistance, preclinical models
- MeSH terms
- Epithelial Cell Adhesion Molecule, Antigens, Neoplasm, Cell Movement, Drug Evaluation, Preclinical, Epidermal Growth Factor, Humans, Models, Biological, RNA, Messenger, Cell Adhesion Molecules, Paclitaxel, Spheroids, Cellular, Cell Culture Techniques, Cell Line, Tumor, Microfluidic Analytical Techniques, Epithelial-Mesenchymal Transition, Tumor Microenvironment, MCF-7 Cells
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.