The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Sorting drops and cells with acoustics: acoustic microfluidic fluorescence-activated cell sorter
Abstract
We describe a versatile microfluidic fluorescence-activated cell sorter that uses acoustic actuation to sort cells or drops at ultra-high rates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Shapiro, H. M. (2003) · Wiley eBooks · doi:10.1002/0471722731 · Cited by 2,671
Formation of dispersions using “flow focusing” in microchannels
Anna, S. L., Bontoux, N., & Stone, H. A. (2003) · Applied Physics Letters · doi:10.1063/1.1537519 · Cited by 2,302
Ultrahigh-throughput screening in drop-based microfluidics for directed evolution
Agresti, J. J., Antipov, E., Abate, A. R., Ahn, K., Rowat, A. C., Baret, J.-C., Marquez, M., Klibanov, A. M., Griffiths, A. D., & Weitz, D. A. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910781107 · Cited by 1,149
Self-citationLighthill, S. J. (1978) · Journal of Sound and Vibration · doi:10.1016/0022-460x(78)90388-7 · Cited by 928
Surface acoustic wave microfluidics
Ding, X., Li, P., Lin, S.-C. S., Stratton, Z. S., Nama, N., Guo, F., Slotcavage, D., Mao, X., Shi, J., Costanzo, F., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50361e · Cited by 926
A microfabricated fluorescence-activated cell sorter
Fu, A. Y., Spence, C., Scherer, A., Arnold, F. H., & Quake, S. R. (1999) · Nature Biotechnology · doi:10.1038/15095 · Cited by 878
Controllable Monodisperse Multiple Emulsions
Chu, L., Utada, A. S., Shah, R. K., Kim, J., & Weitz, D. A. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200701358 · Cited by 747
Self-citationBiocompatible surfactants for water-in-fluorocarbon emulsions
Holtze, C., Rowat, A. C., Agresti, J. J., Hutchison, J. B., Angilè, F. E., Schmitz, C. H. J., Köster, S., Duan, H., Humphry, K. J., Scanga, R. A., et al. (2008) · Lab on a Chip · doi:10.1039/b806706f · Cited by 670
Self-citationDrop-based microfluidic devices for encapsulation of single cells
Köster, S., Angilè, F. E., Duan, H., Agresti, J. J., Wintner, A., Schmitz, C., Rowat, A. C., Merten, C. A., Pisignano, D., Griffiths, A. D., et al. (2008) · Lab on a Chip · doi:10.1039/b802941e · Cited by 518
Self-citationControlled encapsulation of single-cells into monodisperse picolitre drops
Edd, J. F., Di Carlo, D., Humphry, K. J., Köster, S., Irimia, D., Weitz, D. A., & Toner, M. (2008) · Lab on a Chip · doi:10.1039/b805456h · Cited by 511
Self-citationFocusing microparticles in a microfluidic channel with standing surface acoustic waves (SSAW)
Shi, J., Mao, X., Ahmed, D., Colletti, A., & Huang, T. J. (2008) · Lab Chip · doi:10.1039/b716321e · Cited by 439
Marker-specific sorting of rare cells using dielectrophoresis
Hu, X., Bessette, P. H., Qian, J., Meinhart, C. D., Daugherty, P. S., & Soh, H. T. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507719102 · Cited by 428
Surface acoustic wave (SAW) directed droplet flow in microfluidics for PDMS devices
Franke, T., Abate, A. R., Weitz, D. A., & Wixforth, A. (2009) · Lab on a Chip · doi:10.1039/b906819h · Cited by 369
Self-citationSurface acoustic wave actuated cell sorting (SAWACS)
Franke, T., Braunmüller, S., Schmid, L., Wixforth, A., & Weitz, D. A. (2010) · Lab on a Chip · doi:10.1039/b915522h · Cited by 363
Self-citationMicrofluidic, Label-Free Enrichment of Prostate Cancer Cells in Blood Based on Acoustophoresis
Augustsson, P., Magnusson, C., Nordin, M., Lilja, H., & Laurell, T. (2012) · Analytical Chemistry · doi:10.1021/ac301723s · Cited by 352
Valente, P., Fassina, G., Melchiori, A., Masiello, L., Cilli, M., Vacca, A., Onisto, M., Santi, L., Stetler-Stevenson, W. G., & Albini, A. (1998) · International Journal of Cancer · doi:10.1002/(sici)1097-0215(19980119)75:2<246::aid-ijc13>3.0.co;2-b · Cited by 273
Barnkob, R., Augustsson, P., Laurell, T., & Bruus, H. (2012) · Physical Review E · doi:10.1103/physreve.86.056307 · Cited by 268
Bratosin, D., Mitrofan, L., Palii, C., Estaquier, J., & Montreuil, J. (2005) · Cytometry Part A · doi:10.1002/cyto.a.20152 · Cited by 237
Standing surface acoustic wave (SSAW) based multichannel cell sorting
Ding, X., Lin, S.-C. S., Lapsley, M. I., Li, S., Guo, X., Chan, C. Y., Chiang, I.-K., Wang, L., McCoy, J. P., & Huang, T. J. (2012) · Lab on a Chip · doi:10.1039/c2lc40751e · Cited by 224
Shaping acoustic fields as a toolset for microfluidic manipulations in diagnostic technologies
Reboud, J., Bourquin, Y., Wilson, R., Pall, G. S., Jiwaji, M., Pitt, A. R., Graham, A., Waters, A. P., & Cooper, J. M. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1206055109 · Cited by 220
Inhibition of lung metastasis in mice induced by B16F10 melanoma cells by polyphenolic compounds
Menon, L. G., Kuttan, R., & Kuttan, G. (1995) · Cancer Letters · doi:10.1016/0304-3835(95)03887-3 · Cited by 218
A high-throughput label-free nanoparticle analyser
Fraikin, J.-L., Teesalu, T., McKenney, C. M., Ruoslahti, E., & Cleland, A. N. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.24 · Cited by 218
An On-Chip, Multichannel Droplet Sorter Using Standing Surface Acoustic Waves
Li, S., Ding, X., Guo, F., Chen, Y., Lapsley, M. I., Lin, S.-C. S., Wang, L., McCoy, J. P., Cameron, C. E., & Huang, T. J. (2013) · Analytical Chemistry · doi:10.1021/ac400548d · Cited by 181
Seymour, L., Ulbrich, K., Steyger, P., Brereton, M., Subr, V, Strohalm, J., & Duncan, R. (1994) · British Journal of Cancer · doi:10.1038/bjc.1994.363 · Cited by 164
Microfluidic sorting with high-speed single-layer membrane valves
Abate, A. R., Agresti, J. J., & Weitz, D. A. (2010) · Applied Physics Letters · doi:10.1063/1.3431281 · Cited by 135
Self-citationStanding surface acoustic wave (SSAW)-based microfluidic cytometer
Chen, Y., Nawaz, A., Zhao, Y., Huang, P., McCoy, J. P., Levine, S. J., Wang, L., & Huang, T. J. (2014) · Lab on a Chip · doi:10.1039/c3lc51139a · Cited by 126
SAW-controlled drop size for flow focusing
Schmid, L., & Franke, T. (2013) · Lab on a Chip · doi:10.1039/c3lc41233d · Cited by 123
Self-citationSkowronek, V., Rambach, R. W., Schmid, L., et al. (2013) · Analytical Chemistry · doi:10.1021/ac402607p · Cited by 122
Self-citationPhononic crystal structures for acoustically driven microfluidic manipulations
Wilson, R., Reboud, J., Bourquin, Y., Neale, S. L., Zhang, Y., & Cooper, J. M. (2010) · Lab on a Chip · doi:10.1039/c0lc00234h · Cited by 117
Gatti, R., Belletti, S., Orlandini, G., Bussolati, O., Dall’Asta, V., & Gazzola, G. C. (1998) · Journal of Histochemistry & Cytochemistry · doi:10.1177/002215549804600804 · Cited by 109
Tran, S. B. Q., Marmottant, P., & Thibault, P. (2012) · Applied Physics Letters · doi:10.1063/1.4751348 · Cited by 107
Kim, U., & Soh, H. T. (2009) · Lab on a Chip · doi:10.1039/b903950c · Cited by 105
Destgeer, G., Im, S., Ha, B. H., Jung, J. H., Ansari, M. A., & Sung, H. J. (2014) · Applied Physics Letters · doi:10.1063/1.4862322 · Cited by 104
Acoustic actuated fluorescence activated sorting of microparticles
Jakobsson, O., Grenvall, C., Antfolk, M., Evander, M., & Laurell, T. (2014) · Lab on a Chip · doi:10.1039/c3lc51408k · Cited by 93
Phononic Crystals for Shaping Fluids
Bourquin, Y., Wilson, R., Zhang, Y., Reboud, J., & Cooper, J. M. (2011) · Advanced Materials · doi:10.1002/adma.201004455 · Cited by 87
Encapsulation of Capacitive Micromachined Ultrasonic Transducers Using Viscoelastic Polymer
Lin, D.-S., Zhuang, X., Wong, S. H., Kupnik, M., & Khuri-Yakub, B. T. (2010) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2010.2076786 · Cited by 55
Standard Safety Practices for Sorting of Unfixed Cells
Schmid, I., Lambert, C., Ambrozak, D. R., & Perfetto, S. P. (2007) · Current Protocols in Cytometry · doi:10.1002/0471142956.cy0306s39 · Cited by 15
Cited by
Wyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Acoustic tweezers for the life sciences
Ozcelik, A., Rufo, J., Guo, F., Gu, Y., Li, P., Lata, J., & Huang, T. J. (2018) · Nature Methods · doi:10.1038/s41592-018-0222-9 · Cited by 826
Collins, D. J., Neild, A., deMello, A., Liu, A.-Q., & Ai, Y. (2015) · Lab on a Chip · doi:10.1039/c5lc00614g · Cited by 528
Acoustofluidic separation of cells and particles
Wu, M., Ozcelik, A., Rufo, J., Wang, Z., Fang, R., & Jun Huang, T. (2019) · Microsystems & Nanoengineering · doi:10.1038/s41378-019-0064-3 · Cited by 453
Surface Acoustic Wave (SAW) Sensors: Physics, Materials, and Applications
Mandal, D., & Banerjee, S. (2022) · Sensors · doi:10.3390/s22030820 · Cited by 450
Metadata
- Authors
- Schmid, L., Weitz, D. A., & Franke, T.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014
- Volume
- 14
- Issue
- 19
- Pages
- 3710-3718
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2074789706
- Cited by
- 271
- References
- 37
- FWCI
- 16.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.