Flow-induced stress on adherent cells in microfluidic devices
The DOI matches its Crossref record; 166 of the 166 references it cites were found in a registry or an index.
Abstract
The article describes flow-induced stress on adherent cells in microfluidics devices in light of ongoing discoveries in mechanobiology.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Edge effects and high shear stress can also affect the performance and consistency of the device by hindering laminar fl ow in channels, which can harm cells and/or affect their distribution, resulting in inconsistent results which may compromise the predictive value of the platform [68].”
From 3D In Vitro Model (R)evolution: Unveiling Tumor–Stroma Interactions (2021) · cites this paper as [68]
Citations
Cites
Matrix elasticity directs stem cell lineage specification
Engler, A. J., Sen, S., Sweeney, H. L., & Discher, D. E. (2006) · Cell · doi:10.1016/j.cell.2006.06.044 · Cited by 13,915
Endothelium-derived relaxing factor produced and released from artery and vein is nitric oxide.
Ignarro, L. J., Buga, G. M., Wood, K. S., Byrns, R. E., & Chaudhuri, G. (1987) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.84.24.9265 · Cited by 5,074
Geometric Control of Cell Life and Death
Chen, C. S., Mrksich, M., Huang, S., Whitesides, G. M., & Ingber, D. E. (1997) · Science · doi:10.1126/science.276.5317.1425 · Cited by 4,657
Kalluri, R., & Zeisberg, M. (2006) · Nature Reviews Cancer · doi:10.1038/nrc1877 · Cited by 4,538
Angiogenesis in health and disease
Carmeliet, P. (2003) · Nature Medicine · doi:10.1038/nm0603-653 · Cited by 4,276
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Fang, J., Nakamura, H., & Maeda, H. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.04.009 · Cited by 3,559
Mechanotransduction Across the Cell Surface and Through the Cytoskeleton
Wang, N., Butler, J. P., & Ingber, D. E. (1993) · Science · doi:10.1126/science.7684161 · Cited by 3,003
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Research works printed but not linked: 10
- Song, 2010, PLoS One, 5
- Sorkin, 2004, Am. J. Physiol., 287, C1527, 10.1152/ajpcell.00059.2004 · DOI
- Adapala, 2015, Oncogene, 1
- Yamamoto, 2007, Am. J. Physiol., 293, H1646
- Pohl, 1991, Am. J. Physiol., 261, H2016
- Go, 1998, Am. J. Physiol., 275, H1898
- Shyy, 2001, Biorheology, 38, 109
- Huh, 2010, Science, 328, 1662, 10.1126/science.1188302 · DOI · Paper page
- McBride, 2008, Tissue Eng. Part A, 14, 1573, 10.1089/ten.tea.2008.0113 · DOI
- Chang, 2011, Mol. Cell Biomech., 8, 297
Cited by
Items 101–165 of 165
Yu, S., Jiang, L., Song, M., Yang, T., Yuan, M., Chen, X., & Shu, H. (2025) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2025.1599509 · Cited by 8
Neal, A. S., Rountree, A. M., Radtke, J. R., Yin, J., Schwartz, M. W., Hampe, C. S., Posner, J. D., Cirulli, V., & Sweet, I. R. (2016) · Scientific Reports · doi:10.1038/srep39319 · Cited by 8
MAGNETOPHORETIC CIRCUIT BIOCOMPATIBILITY
Abedini‐Nassab, R. (2020) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519420500505 · Cited by 8
Shearmetry of Fluids with Tunable Rheology by Polarized Luminescence of Rare Earth-Doped Nanorods
Wang, Z., Zou, Q., Magermans, L., Amselem, G., Dessalles, C. A., Louis, B., Filoche, M., Gacoin, T., & Kim, J. (2024) · ACS Nano · doi:10.1021/acsnano.4c09493 · Cited by 7
Vessel-on-a-Chip: A Powerful Tool for Investigating Endothelial COVID-19 Fingerprints
Shevchuk, O. O., Palii, S. M., Pak, A., Chantada, N., Seoane, N., Korda, M. M., Campos‐Toimil, M., & Álvarez, E. (2023) · Cells · doi:10.3390/cells12091297 · Cited by 7
Continuous flow delivery system for the perfusion of scaffold-based 3D cultures
Sitte, Z. R., Karlsson, E., Li, H., Zhou, H., & Lockett, M. R. (2024) · Lab on a Chip · doi:10.1039/d4lc00480a · Cited by 6
The morphology of cell spheroids in simple shear flow
Ferraro, R., Franco, J. D., Caserta, S., & Guido, S. (2024) · Frontiers in Physics · doi:10.3389/fphy.2024.1347934 · Cited by 6
Babaliari, E., Kavatzikidou, P., Xydias, D., Psilodimitrakopoulos, S., Ranella, A., & Stratakis, E. I. (2025) · Micromachines · doi:10.3390/mi16030341 · Cited by 5
Hossain, M. K., & Kim, H.-R. (2026) · International Journal of Molecular Sciences · doi:10.3390/ijms27031280 · Cited by 5
In vitro magnetohydrodynamics system for modulating cell migration
Gebreyesus, E. A., Park, A., Guldberg, R. E., & Ong, K. G. (2023) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/acb711 · Cited by 5
Putra, V. D. L., Jalilian, I., Campbell, M., Poole, K., Whan, R. M., Tomasetig, F., & Tate, M. L. K. (2019) · BIO-PROTOCOL · doi:10.21769/bioprotoc.3439 · Cited by 5
Self-citationDash, S. K., Rahman, M. A., Yi, B., Williams, B., Lim, G., Zhou, S., Zou, P., Li, Y., Mahler, G. J., & Zhang, T. (2025) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2025.103767 · Cited by 4
Park, S., Lee, S.-H., Park, G., & Choi, J. (2026) · Food Research International · doi:10.1016/j.foodres.2026.118616 · Cited by 3
Why 3D in vitro cancer models are the future of cancer research?
Petrić, T., & Sabol, M. (2023) · Periodicum Biologorum · doi:10.18054/pb.v124i3-4.24697 · Cited by 3
Hu, S.-Y., Xue, C., Li, Y., Li, S., Gao, Z., & Qin, K. (2024) · Mechanobiology in Medicine · doi:10.1016/j.mbm.2024.100069 · Cited by 3
In vitro Approaches to Model Breast Tumor Complexity
Rosado-Galindo, H. M., Suarez, L., & Domenech, M. (2021) · IntechOpen eBooks · doi:10.5772/intechopen.96338 · Cited by 3
Investigation on the effects of variable shear stress on monocyte cell morphology
Birol, S. Z., Fucucuoglu, R., Çadırcı, S., Sayi‐Yazgan, A., & Trabzon, L. (2017) · Micro & Nano Letters · doi:10.1049/mnl.2017.0432 · Cited by 3
Micro-tweezers and Force Microscopy Techniques for Single-Cell Mechanobiological Analysis
Gong, L., Qian, W., Morales, R.-T. T., Tong, J., Bajpai, A., & Chen, W. (2021) · Springer eBooks · doi:10.1007/978-981-10-8953-4_39 · Cited by 3
Gong, L., Eskandari, E., Khan, M. A. R., & Yang, L. (2026) · Lab on a Chip · doi:10.1039/d6lc00116e · Cited by 2
Where the wild molecules are: Engineering the spatial distribution of signaling molecules
Zhu, X., Neu, E., & Wong, W. W. (2024) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2024.100551 · Cited by 2
Single Live Cell Assays with Label-free Optical Biosensor for the Development of Diagnostic Methods
Sallai, I. (2025) · International Spring Seminar on Electronics Technology · doi:10.1109/isse65583.2025.11121062 · Cited by 2
Liao, W., Yi, L., He, W., Yang, S., Zhang, P., Weng, T., & Xu, Y. (2023) · Microfluidics and Nanofluidics · doi:10.1007/s10404-023-02635-6 · Cited by 2
Forces in a microvessel-on-chip : system development,poroelasticity mechanics and cellular response
Dessalles, C. A. (2021) · theses.fr (ABES) · doi:10.70675/5fc1fb53z8432z4709z891cz8bf087f8ff29 · Cited by 2
Can boundary slip destabilize rotating microchannel flows?
Sengupta, S., & Chakraborty, S. (2024) · Physics of Fluids · doi:10.1063/5.0231804 · Cited by 1
Bérešová, L., Víteček, J., Protivankova, I., Dudka, M., Chromá, K., Škrott, Z., Buchtová, T., Poláková, K., Novotný, J., Nováková, L., et al. (2025) · Scientific Reports · doi:10.1038/s41598-024-83058-3 · Cited by 1
Microfluidics-Based Platforms for Tissue Engineering and Regenerative Medicine
García‐Gareta, E., & Garcia-Aznar, J. M. (2026) · Series in bioengineering · doi:10.1007/978-3-032-03441-0_10 · Cited by 1
Low-cost, tape-sealed, PDMS-molded devices using 3D printing for cell adhesion under flow
Kreznor, A. F., Bossmann, S. H., & Culbertson, C. T. (2026) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-026-06360-1 · Cited by 1
Ruarte, D. (2020) · Journal of Science Humanities and Arts - JOSHA · doi:10.17160/josha.7.5.706 · Cited by 1
Fluid Flow Dependency in Immunoselective Cell Capture via Liquid Biopsy
Ostrikov, K., Kashani, M. N., Vasilev, K. A., & MacGregor, M. (2021) · Langmuir · doi:10.1021/acs.langmuir.1c01998 · Cited by 1
Abedini‐Nassab, R. (2023) · Springer eBooks · doi:10.1007/978-981-99-1702-0_7 · Cited by 1
Mario, M. L., & Casado, F. L. (2023) · IEEE Nanotechnology Materials and Devices Conference (NMDC) · doi:10.1109/nmdc57951.2023.10343830 · Cited by 1
Biomedical devices engineered based on the control of the surface wettability
Oliveira, N. M. (2017) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · Cited by 1
A Computational Fluid Dynamics study of scaffolds under perfusion flow
Chinchilla-Mendez, J. A. (2022) · Queensland University of Technology · doi:10.5204/thesis.eprints.231384 · Cited by 1
Eslam, H. M., Tabatabaei, S. N., Fayazbakhsh, F., Salami, S. A., & Ghanbari, H. (2022) · Research Square · doi:10.21203/rs.3.rs-1643369/v2 · Cited by 1
Concentration gradient generation for microfluidic applications
Toh, A. G. G. (2016) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/69096
Micro-scale fluorescence in situ hybridization
Huber, D. (2018) · Repository for Publications and Research Data (ETH Zurich) · doi:10.3929/ethz-b-000286523
Microfluidic Organs-on-Chips to Reconstitute Cellular Microenvironments
Torisawa, Y. (2019) · Bioanalysis · doi:10.1007/978-981-13-6229-3_8
Engineering of vascular networks using microfluidic devices for organ-on-a-chip microsystems
Torisawa, Y. (2019) · Drug Delivery System · doi:10.2745/dds.34.268
Micro-tweezers and Force Microscopy Techniques for Single-Cell Mechanobiological Analysis
Gong, L., Qian, W., Morales, R.-T. T., Tong, J., Bajpai, A., & Chen, W. (2019) · Springer eBooks · doi:10.1007/978-981-10-4857-9_39-1
Paoli, R. (2019) · Dipòsit Digital de la Universitat de Barcelona (Universitat de Barcelona)
Peñaherrera, A. (2020) · Journal of Science Humanities and Arts - JOSHA · doi:10.17160/josha.7.3.671
Integration of Cellular Analysis Methods into Microphysiological Vascular Models
Wong, J. F. (2020) · TSpace (University of Toronto)
Microfluidic Organs-on-Chips to Reconstitute Cellular Microenvironments
Torisawa, Y. (2024) · Bioanalysis · doi:10.1007/978-981-97-6540-9_8
Noguchi, Y., Kunishige, R., Shinozaki‐Narikawa, N., Yamashita, H., Aihara, K., Murata, M., & Kano, F. (2025) · Communications Biology · doi:10.1038/s42003-025-08916-w
Assessment of Mechanical Cues to Enhance the Clinical Translation of Extracellular Vesicles
Kronstadt, S. M. (2022) · University Libraries (University of Maryland) · doi:10.13016/dwzj-qlcl
Fluid-walled microfluidics for cell migration studies
Deroy, C. (2021) · Oxford University Research Archive (ORA) (University of Oxford) · doi:10.5287/ora-w4jzbvqn6
Lira Camargo, M. M. (2023) · Communities in DSpace (Pontifical Catholic University of Peru)
Microfluidic-based analysis of 3D cell migration under different biophysical and chemical gradients
Amo Mateos, C. D., & GARCÍA AZNAR, J. M. (2019) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Cheng, Y.-W. (2023) · D-Scholarship@Pitt (University of Pittsburgh)
Use and fabrication of microfluidic circuits formed with submerged microjets
Stovall-Kurtz, N. (2021) · Oxford University Research Archive (ORA) (University of Oxford) · doi:10.5287/ora-aedr9v266
Gómez, A. H. (2025) · Dipòsit Digital de la Universitat de Barcelona (Universitat de Barcelona)
New microfluidic systems for controlling the cell microenvironment during live-cell imaging
Babic, J. (2017) · theses.fr (ABES) · doi:10.70675/04bd07d1z3432z4763z8f11z544747af5ee0
Takeuchi, Y., Hikichi, Y., Ishikawa, S., Ide, Y., Akaike, M., Saito, Y., NAKANISHI, Y., & Nakashima, Y. (2026) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2026.139917
A vacuum-driven microfluidic platform for single-cell elastic modulus measurement
Ye, X., An, W., Zhou, X., Chen, Q., & Zheng, B. (2026) · Biomicrofluidics · doi:10.1063/5.0333861
MICROPLASTICS DETECTION, CHARACTERIZATION, AND CYTOTOXICITY EVALUATION VIA LAB-ON-CHIP
Gong, L. (2025) · Digital Commons - URI (University of Rhode Island) · doi:10.23860/diss-4453
Munoz, J. M., Valle, N. M. E., Liu, C. M., Alves, A. H., Pileggi, G. F., Mamani, J. B., da Costa, M. F., da Silva, K. F., Galanciak, M. C. S., Rosário, G. M., et al. (2026) · Biomedicines · doi:10.3390/biomedicines14091879
Pinon, L., Debache, A., Thuaud, A., Tiraboschi, L., Vella, G., Riou-Ramon, J., Cordier, C., Helal, C., Hersen, P., Rescigno, M., et al. (2026) · Communications Biology · doi:10.1038/s42003-026-10675-1
Kreznor, A. F. (2024) · K-State Research Exchange (Kansas State University)
O'Reilly, C., Dev, K. K., & Basu, B. (2026) · Lab on a Chip · doi:10.1039/d6lc00544f
Heart-Mimicking Haptic Interface for Mechanobiology Research
Costabile, D., Villani, A., & Prattichizzo, D. (2026) · Lecture notes in networks and systems · doi:10.1007/978-3-032-33874-7_6
Microfluidic engineering for organoid formation, cultivation, and sensing
Kushnir, I. A., Salina, K. O., Bogolubova, Y. A., Mushegian, T. M., Dragun, M. A., Volegova, D. D., Polynkin, L. Y., Kopylova, A. A., Salmina, A. B., & Yurchenko, S. O. (2026) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2026.1994650
Toward a Fibroid-on-a-Chip: Lessons from Reproductive Organ-on-a-Chip Models
Salvini, L., Zagnoni, M., Sandison, M. E., Hapangama, D. K., Segars, J. H., & Islam, M. S. (2026) · Cellular and Molecular Bioengineering · doi:10.1007/s12195-026-00964-4
Hydrodynamic and diffusive control of linear concentration gradients in a microfluidic channel
Hyun, J. Y., Lee, Y. J., Kim, S. M., & Lee, S. Y. (2026) · Microfluidics and Nanofluidics · doi:10.1007/s10404-026-02955-3
Weller, A., Hansen, M. B., Marie, R., Hundahl, A. C., Hempel, C., Kempen, P. J., Frandsen, H. L., Parhamifar, L., Larsen, J. B., & Andresen, T. L. (2022) · doi:10.3389/fbioe.2022.965200.s001
Metadata
- Authors
- Shemesh, J., Jalilian, I., Shi, A., Heng Yeoh, G., Knothe Tate, M. L., & Ebrahimi Warkiani, M.
- Affiliations
- UNSW Sydney (AU)
- School of Mechanical and Manufacturing Engineering
- Graduate School of Biomedical Engineering
- ORCID
- Shemesh, Jonathan
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2015
- Volume
- 15
- Issue
- 21
- Pages
- 4114-4127
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1872647657
- Cited by
- 144
- References
- 166
- Citations by year
- 2026: 7 · 2025: 13 · 2024: 11 · 2023: 13 · 2022: 15 · 2021: 17 · 2020: 16 · 2019: 13 · 2018: 10 · 2017: 16 · 2016: 11 · 2015: 2
- FWCI
- 1.30
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Keywords
- flow-induced stress, adherent cells, microfluidics, mechanobiology, shear flow, cell-matrix adhesion, endothelial cell alignment, parallel plate flow chamber
- MeSH terms
- Animals, Cell Adhesion, Humans, Stress, Mechanical, Mechanotransduction, Cellular, Lab-On-A-Chip Devices, Hydrodynamics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.