Flow-induced stress on adherent cells in microfluidic devices
The DOI matches its Crossref record; 166 of the 166 references it cites were found in a registry or an index.
Abstract
The article describes flow-induced stress on adherent cells in microfluidics devices in light of ongoing discoveries in mechanobiology.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Edge effects and high shear stress can also affect the performance and consistency of the device by hindering laminar fl ow in channels, which can harm cells and/or affect their distribution, resulting in inconsistent results which may compromise the predictive value of the platform [68].”
From 3D In Vitro Model (R)evolution: Unveiling Tumor–Stroma Interactions (2021) · cites this paper as [68]
Citations
Cites
Matrix elasticity directs stem cell lineage specification
Engler, A. J., Sen, S., Sweeney, H. L., & Discher, D. E. (2006) · Cell · doi:10.1016/j.cell.2006.06.044 · Cited by 13,915
Endothelium-derived relaxing factor produced and released from artery and vein is nitric oxide.
Ignarro, L. J., Buga, G. M., Wood, K. S., Byrns, R. E., & Chaudhuri, G. (1987) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.84.24.9265 · Cited by 5,074
Geometric Control of Cell Life and Death
Chen, C. S., Mrksich, M., Huang, S., Whitesides, G. M., & Ingber, D. E. (1997) · Science · doi:10.1126/science.276.5317.1425 · Cited by 4,657
Kalluri, R., & Zeisberg, M. (2006) · Nature Reviews Cancer · doi:10.1038/nrc1877 · Cited by 4,538
Angiogenesis in health and disease
Carmeliet, P. (2003) · Nature Medicine · doi:10.1038/nm0603-653 · Cited by 4,276
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Fang, J., Nakamura, H., & Maeda, H. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.04.009 · Cited by 3,559
Mechanotransduction Across the Cell Surface and Through the Cytoskeleton
Wang, N., Butler, J. P., & Ingber, D. E. (1993) · Science · doi:10.1126/science.7684161 · Cited by 3,003
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Research works printed but not linked: 10
- Song, 2010, PLoS One, 5
- Sorkin, 2004, Am. J. Physiol., 287, C1527, 10.1152/ajpcell.00059.2004 · DOI
- Adapala, 2015, Oncogene, 1
- Yamamoto, 2007, Am. J. Physiol., 293, H1646
- Pohl, 1991, Am. J. Physiol., 261, H2016
- Go, 1998, Am. J. Physiol., 275, H1898
- Shyy, 2001, Biorheology, 38, 109
- Huh, 2010, Science, 328, 1662, 10.1126/science.1188302 · DOI · Paper page
- McBride, 2008, Tissue Eng. Part A, 14, 1573, 10.1089/ten.tea.2008.0113 · DOI
- Chang, 2011, Mol. Cell Biomech., 8, 297
Cited by
3D In Vitro Model (R)evolution: Unveiling Tumor–Stroma Interactions
Rodrigues, J., Heinrich, M. A., Teixeira, L. M., & Prakash, J. (2021) · Trends in Cancer · doi:10.1016/j.trecan.2020.10.009 · Cited by 405
“Edge effects and high shear stress can also affect the performance and consistency of the device by hindering laminar flow in channels, which can harm cells and/or affect their distribution, resulting in inconsistent results which may compromise the predictive value of the platform [68].”
BackgroundTumor microenvironment: barrier or opportunity towards effective cancer therapy
Tiwari, A., Trivedi, R., & Lin, S.-Y. (2022) · Journal of Biomedical Science · doi:10.1186/s12929-022-00866-3 · Cited by 377
Microfluidic organ-on-chip technology for blood-brain barrier research
van der Helm, M. W., van der Meer, A. D., Eijkel, J. C. T., van den Berg, A., & Segerink, L. I. (2016) · Tissue Barriers · doi:10.1080/21688370.2016.1142493 · Cited by 333
Tumor microenvironment signaling and therapeutics in cancer progression
Goenka, A., Khan, F., Verma, B., Sinha, P., Dmello, C. C., Jogalekar, M. P., Gangadaran, P., & Ahn, B. (2023) · Cancer Communications · doi:10.1002/cac2.12416 · Cited by 323
Integration of substrate- and flow-derived stresses in endothelial cell mechanobiology
Dessalles, C. A., Leclech, C., Castagnino, A., & Barakat, A. I. (2021) · Communications Biology · doi:10.1038/s42003-021-02285-w · Cited by 230
Size, shape, and flexibility influence nanoparticle transport across brain endothelium under flow
Nowak, M., Brown, T. D., Graham, A., Helgeson, M. E., & Mitragotri, S. (2020) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10153 · Cited by 211
Huber, D., Oskooei, A., Solvas, X. C. I., deMello, A. J., & Kaigala, G. V. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00317 · Cited by 139
Conducting Polymer Scaffolds for Hosting and Monitoring 3D Cell Culture
Inal, S., Hama, A., Ferro, M. P., Pitsalidis, C., Oziat, J., Iandolo, D., Pappa, A., Hadida, M., Huerta, M., Marchat, D., et al. (2017) · Advanced Biosystems · doi:10.1002/adbi.201700052 · Cited by 132
Barisam, M., Saidi, M. S., Kashaninejad, N., & Nguyen, N. (2018) · Micromachines · doi:10.3390/mi9030094 · Cited by 128
Vascular endothelial cell mechanosensing: New insights gained from biomimetic microfluidic models
Gray, K. M., & Stroka, K. M. (2017) · Seminars in Cell and Developmental Biology · doi:10.1016/j.semcdb.2017.06.002 · Cited by 120
A Microfluidic System for Studying the Effects of Disturbed Flow on Endothelial Cells
Tovar-Lopez, F. J., Thurgood, P., Gilliam, C., Nguyen, N., Pirogova, E., Khoshmanesh, K., & Baratchi, S. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00081 · Cited by 116
Cultivating Multidisciplinarity: Manufacturing and Sensing Challenges in Cultured Meat Production
Djisalov, M., Knežić, T., Podunavac, I., Živojević, K., Radonić, V., Knežević, N. Ž., Bobrinetskiy, I. I., & Gadjanski, I. (2021) · Biology · doi:10.3390/biology10030204 · Cited by 111
A microfluidic model of human brain (μHuB) for assessment of blood brain barrier
Brown, T. D., Nowak, M., Bayles, A. V., Prabhakarpandian, B., Karande, P., Lahann, J., Helgeson, M. E., & Mitragotri, S. (2019) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10126 · Cited by 106
Translational Roadmap for the Organs-on-a-Chip Industry toward Broad Adoption
Allwardt, V., Ainscough, A. J., Viswanathan, P., Sherrod, S. D., McLean, J. A., Haddrick, M., & Pensabene, V. (2020) · Bioengineering · doi:10.3390/bioengineering7030112 · Cited by 88
Chen, H., Yu, Z., Bai, S., Lu, H., Xu, D. L., Chen, C., Li, J., & Zhu, Y. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.06.023 · Cited by 86
3D gut-liver chip with a PK model for prediction of first-pass metabolism
Lee, D. W., Ha, S. K., Choi, I., & Sung, J. H. (2017) · Biomedical Microdevices · doi:10.1007/s10544-017-0242-8 · Cited by 85
A Gut-Brain Axis-on-a-Chip for studying transport across epithelial and endothelial barriers
Kim, M., Kim, D., & Sung, J. H. (2021) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2021.06.021 · Cited by 84
Microscale Bioreactors for in situ characterization of GI epithelial cell physiology
Costello, C. M., Phillipsen, M. B., Hartmanis, L., Kwasnica, M. A., Chen, V., Hackam, D. J., Chang, M. W., Bentley, W. E., & March, J. C. (2017) · Scientific Reports · doi:10.1038/s41598-017-12984-2 · Cited by 78
Hassanzadeh‐Barforoushi, A., Sango, X., Johnston, E. L., Haylock, D. N., & Wang, Y. (2025) · Journal of Extracellular Vesicles · doi:10.1002/jev2.70132 · Cited by 77
Wu, F., Su, R., Lai, Y., & Wang, X. (2017) · eLife · doi:10.7554/elife.23702 · Cited by 76
Shear stress: An essential driver of endothelial progenitor cells
Kutikhin, A. G., Sinitsky, M. Y., Yuzhalin, A. E., & Velikanova, E. A. (2018) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2018.03.007 · Cited by 75
High-Throughput Routes to Biomaterials Discovery
Soheilmoghaddam, M., Rumble, M., & Cooper-White, J. J. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01026 · Cited by 72
Mitrakas, A. G., Tsolou, A., Didaskalou, S., Karkaletsou, L., Efstathiou, C., Eftalitsidis, E., Marmanis, K., & Koffa, M. D. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms24086949 · Cited by 73
Sticker, D., Lechner, S., Jungreuthmayer, C., Zanghellini, J., & Ertl, P. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03886 · Cited by 69
Sönmez, U. M., Cheng, Y.-W., Watkins, S. C., Roman, B. L., & Davidson, L. A. (2020) · Lab on a Chip · doi:10.1039/d0lc00738b · Cited by 69
Shourabi, A. Y., Kashaninejad, N., & Saidi, M. S. (2021) · Journal of Science Advanced Materials and Devices · doi:10.1016/j.jsamd.2021.02.009 · Cited by 68
3D Cancer Models: Depicting Cellular Crosstalk within the Tumour Microenvironment
Franchi-Mendes, T., Eduardo, R., Domenici, G., & Brito, C. (2021) · Cancers · doi:10.3390/cancers13184610 · Cited by 67
Peng, H., Chao, Z., Wang, Z., Hao, X., Xi, Z., Ma, S., Guo, X., Zhang, J., Zhou, Q., Qu, G., et al. (2025) · Experimental Hematology and Oncology · doi:10.1186/s40164-024-00591-7 · Cited by 64
Lindner, M., Laporte, A., Block, S., Elomaa, L., & Weinhart, M. (2021) · Cells · doi:10.3390/cells10082062 · Cited by 63
Engineering multiscale structural orders for high-fidelity embryoids and organoids
Shao, Y., & Fu, J. (2022) · Cell stem cell · doi:10.1016/j.stem.2022.04.003 · Cited by 62
Shao, X., Gao, D., Chen, Y., Jin, F., Hu, G., Jiang, Y., & Liu, H. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.06.028 · Cited by 62
A microfluidic chip with gravity‐induced unidirectional flow for perfusion cell culture
Lee, D. W., Choi, N., & Sung, J. H. (2019) · Biotechnology Progress · doi:10.1002/btpr.2701 · Cited by 54
Mohammed, M. M., Thurgood, P., Gilliam, C., Nguyen, N., Pirogova, E., Peter, K., Khoshmanesh, K., & Baratchi, S. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03247 · Cited by 58
Sano, E., Mori, C., Matsuoka, N., Ozaki, Y., Yagi, K., Wada, A., Tashima, K., Yamasaki, S., Tanabe, K., Yano, K., et al. (2019) · Micromachines · doi:10.3390/mi10110793 · Cited by 57
Mechanical Characterization for Cellular Mechanobiology: Current Trends and Future Prospects
Narasimhan, B. N., Ting, M. S., Kollmetz, T., Horrocks, M. S., Chalard, A. E., & Malmström, J. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.595978 · Cited by 54
Rath, H., Stumpp, S. N., & Stiesch, M. (2017) · PLoS ONE · doi:10.1371/journal.pone.0172095 · Cited by 48
Wang, D., Dong, R., Wang, X., & Jiang, X. (2022) · ACS Nano · doi:10.1021/acsnano.1c09807 · Cited by 45
Skin-on-a-chip technologies towards clinical translation and commercialization
Ismayilzada, N., Tarar, C., Dabbagh, S. R., Tokyay, B. K., Dilmani, S. A., Sokullu, E., Abaci, H. E., & Taşoğlu, S. (2024) · Biofabrication · doi:10.1088/1758-5090/ad5f55 · Cited by 43
Rodrigues, J., Sarmento, B. F. C. C., & Pereira, C. L. (2022) · In vitro models · doi:10.1007/s44164-022-00008-x · Cited by 42
Cellular Aquaculture: Prospects and Challenges
Goswami, M., Shambhugowda, Y. B., Sathiyanarayanan, A., Pinto, N., Duscher, A. A., Ovissipour, R., Lakra, W. S., & Nagarajarao, R. C. (2022) · Micromachines · doi:10.3390/mi13060828 · Cited by 42
Kucińska, M., Murias, M., & Nowak-Sliwinska, P. M. (2016) · Mutation Research/Reviews in Mutation Research · doi:10.1016/j.mrrev.2016.09.002 · Cited by 41
Barisam, M., Saidi, M. H., Kashaninejad, N., Vadivelu, R. K., & Nguyen, N. (2017) · Micromachines · doi:10.3390/mi8120358 · Cited by 37
Blood brain barrier: A tissue engineered microfluidic chip
Musafargani, S., Mishra, S., Gulyás, M., Mahalakshmi, P., Archunan, G., Padmanabhan, P., & Gulyás, B. Z. (2019) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108525 · Cited by 36
Hesari, Z., Soleimani, M., Atyabi, F., Sharifdini, M., Nadri, S., Warkiani, M. E., Zare, M., & Dinarvand, R. (2016) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35689 · Cited by 36
Hydrogel-incorporating unit in a well: 3D cell culture for high-throughput analysis
Yu, Y. J., Kim, Y. H., Na, K., Min, S. Y., Hwang, O. K., Park, D. K., Kim, D. Y., Choi, S. H., Kamm, R. D., Chung, S. H., et al. (2018) · Lab on a Chip · doi:10.1039/c8lc00525g · Cited by 35
Transitional Remodeling of the Hepatic Extracellular Matrix in Alcohol-Induced Liver Injury
Poole, L. G., & Arteel, G. E. (2016) · BioMed Research International · doi:10.1155/2016/3162670 · Cited by 35
Healthy and diseased in vitro models of vascular systems
Hosseini, V., Mallone, A., Nasrollahi, F., Ostrovidov, S., Nasiri, R., Mahmoodi, M., Haghniaz, R., Baidya, A., Salek, M. M., Darabi, M. A., et al. (2021) · Lab on a Chip · doi:10.1039/d0lc00464b · Cited by 34
Caring for cells in microsystems: principles and practices of cell-safe device design and operation
Varma, S., & Voldman, J. (2018) · Lab on a Chip · doi:10.1039/c8lc00746b · Cited by 34
Three-Dimensional Modeling of Avascular Tumor Growth in Both Static and Dynamic Culture Platforms
Taghibakhshi, A., Barisam, M., Saidi, M. S., Kashaninejad, N., & Nguyen, N. (2019) · Micromachines · doi:10.3390/mi10090580 · Cited by 32
Emerging Technologies and Materials for High-Resolution 3D Printing of Microfluidic Chips
Kotz, F., Helmer, D., & Rapp, B. E. (2020) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2020_141 · Cited by 31
In Vitro Flow Chamber Design for the Study of Endothelial Cell (Patho)Physiology
Fallon, M. E., Mathews, R., & Hinds, M. T. (2021) · Journal of Biomechanical Engineering · doi:10.1115/1.4051765 · Cited by 31
Yesilköy, F., Ueno, R., Desbiolles, B. X. E., Grisi, M., Sakai, Y., Kim, B., & Brügger, J. (2016) · Biomicrofluidics · doi:10.1063/1.4942457 · Cited by 31
Microdevice-based mechanical compression on living cells
Önal, S., Alkaisi, M. M., & Nock, V. (2022) · iScience · doi:10.1016/j.isci.2022.105518 · Cited by 30
Devadas, D., Moore, T. A., Walji, N., & Young, E. W. K. (2019) · Biomicrofluidics · doi:10.1063/1.5123912 · Cited by 29
Flexible Three-Dimensional Net for Intravascular Fishing of Circulating Tumor Cells
Cheng, S., Wang, M., Zhang, C., Chen, M., Wang, Y., Tian, S., Zhan, N., Dong, W., Xie, M., & Huang, W. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c00203 · Cited by 28
Liu, Y., Xue, X., Sun, S., Kobayashi, N., Kim, Y. S., & Fu, J. (2023) · Nature Reviews Physics · doi:10.1038/s42254-023-00669-x · Cited by 27
Microfluidic Systems with Embedded Cell Culture Chambers for High-Throughput Biological Assays
Jaberi, A., Esfahani, A. M., Aghabaglou, F., Park, J. S., Ndao, S., Tamayol, A., & Yang, R. (2020) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c00439 · Cited by 27
Determination of protein–protein interactions at the single-molecule level using optical tweezers
Sánchez, W. N., Robeson, L., Carrasco, V., Figueroa, N. L., Burgos‐Bravo, F., Wilson, C. A. M., & Casanova‐Morales, N. (2022) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583522000075 · Cited by 26
Omrani, V., Targhi, M. Z., Rahbarizadeh, F., & Nosrati, R. (2023) · Scientific Reports · doi:10.1038/s41598-023-30275-x · Cited by 26
Bioengineered microfluidic blood-brain barrier models in oncology research
Augustine, R., Aqel, A. H., Kalva, S. N., Joshy, K. S., Nayeem, A., & Hasan, A. (2021) · Translational Oncology · doi:10.1016/j.tranon.2021.101087 · Cited by 26
Soffe, R., Baratchi, S., Nasabi, M., Tang, S., Boes, A., McIntyre, P., Mitchell, A., & Khoshmanesh, K. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.05.145 · Cited by 25
Miura, T., & Yokokawa, R. (2016) · Development Growth & Differentiation · doi:10.1111/dgd.12292 · Cited by 25
Dash, S. K., Patra, B., Sharma, V., Das, S. K., & Verma, R. S. (2022) · Lab on a Chip · doi:10.1039/d1lc01139a · Cited by 23
Cell Migration Assays and Their Application to Wound Healing Assays—A Critical Review
Yang, C., Yin, D., Zhang, H., Badea, I., Yang, S.-M., & Zhang, W. (2024) · Micromachines · doi:10.3390/mi15060720 · Cited by 22
Siren, E. M. J., Luo, H. D., Bajaj, S., MacKenzie, J., Daneshi, M., Martinez, D. M., Conway, E. M., Cheung, K. C., & Kizhakkedathu, J. N. (2021) · The FASEB Journal · doi:10.1096/fj.201802376rrrr · Cited by 22
Dash, S. K., Sharma, V., Verma, R. S., & Das, S. K. (2020) · Biomicrofluidics · doi:10.1063/5.0024437 · Cited by 22
A simple microfluidic device to study cell-scale endothelial mechanotransduction
Lafaurie-Janvore, J., Antoine, E. E., Perkins, S., Babataheri, A., & Barakat, A. I. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0090-y · Cited by 21
Developments of microfluidics for orthopedic applications: A review
Sun, M., Gong, J., Cui, W., Li, C., Yu, M., Ye, H., Cui, Z., Chen, J., He, Y., Liu, A., et al. (2022) · Smart Materials in Medicine · doi:10.1016/j.smaim.2022.07.001 · Cited by 20
Ichikawa, Y., Yamamoto, K., & Motosuke, M. (2018) · Microfluidics and Nanofluidics · doi:10.1007/s10404-018-2095-8 · Cited by 20
Computational analysis of integrated biosensing and shear flow in a microfluidic vascular model
Wong, J. F., Young, E. W. K., & Simmons, C. A. (2017) · AIP Advances · doi:10.1063/1.5006655 · Cited by 20
Production of monoclonal antibodies in microfluidic devices
Bourguignon, N., Attallah, C. V., Karp, P. M., Booth, R., Peñaherrera, A., Payés, C., Oggero, M., Pérez, M., Helguera, G. F., & Lerner, B. (2018) · Integrative Biology · doi:10.1039/c7ib00200a · Cited by 19
Novel multi-functional fluid flow device for studying cellular mechanotransduction
Lyons, J. S., Iyer, S. R., Lovering, R. M., Ward, C. W., & Stains, J. P. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.11.051 · Cited by 19
Melrose, J. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms26062554 · Cited by 18
Varma, S., Fendyur, A., Box, A., & Voldman, J. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00256 · Cited by 18
Lee, H. M., Sung, J., Ko, B., Lee, H.-W., Park, S., So, H., & Yoon, G. H. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104412 · Cited by 18
Predicting flows through microfluidic circuits with fluid walls
Deroy, C., Stovall‐Kurtz, N., Nebuloni, F., Soitu, C., Cook, P. R., & Walsh, E. J. (2021) · Microsystems & Nanoengineering · doi:10.1038/s41378-021-00322-6 · Cited by 18
Combinational concentration gradient confinement through stagnation flow
Alicia, T. G. G., Yang, C., Wang, Z., & Nguyen, N. (2015) · Lab on a Chip · doi:10.1039/c5lc01137j · Cited by 17
Özkayar, G., Lötters, J. C., Tichem, M., & Ghatkesar, M. K. (2022) · Biomicrofluidics · doi:10.1063/5.0074156 · Cited by 17
Yang, J. R., Gu, Y., Zhang, C., Zhang, Y., Liang, W., Hao, L., Zhao, Y., Liu, L., & Wang, W. (2022) · Lab on a Chip · doi:10.1039/d2lc00512c · Cited by 16
Limjanthong, N., Tohbaru, Y., Okamoto, T., Okajima, R., Kusama, Y., Kojima, H., Fujimura, A., Miyazaki, T., Kanamori, T., Sugiura, S., et al. (2022) · Journal of Bioscience and Bioengineering · doi:10.1016/j.jbiosc.2022.11.007 · Cited by 15
Hajj, S. E., Ntaté, M. B., Breton, C., Siadous, R., Aid, R., Dupuy, M., Letourneur, D., Amédée, J., Duval, H., & David, B. (2024) · Gels · doi:10.3390/gels10100666 · Cited by 15
Jouybar, M., van der Kallen, S., Sahebali, S. S., Bouten, C. V. C., & den Toonder, J. M. J. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202401994 · Cited by 16
Modeling of a fast-response magnetic-sensitive hydrogel for dynamic control of microfluidic flow
Liu, Q., Li, H., & Lam, K. Y. (2018) · Physical Chemistry Chemical Physics · doi:10.1039/c8cp06556j · Cited by 15
In Pursuit of Designing Multicellular Engineered Living Systems: A Fluid Mechanical Perspective
Serrano, J. C., Gupta, S. K., Kamm, R. D., & Guo, M. (2020) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-072220-013845 · Cited by 15
Passive controlled flow for Parkinson's disease neuronal cell culture in 3D microfluidic devices
Kane, K. I. W., Jarazo, J., Moreno, E. L., Fleming, R. M. T., & Schwamborn, J. C. (2020) · Organs-on-a-Chip · doi:10.1016/j.ooc.2020.100005 · Cited by 14
Babaliari, E., Kavatzikidou, P., Mitraki, A., Papaharilaou, Y., Ranella, A., & Stratakis, E. I. (2020) · Biomaterials Science · doi:10.1039/d0bm01218a · Cited by 14
Microfluidic Systems for Neural Cell Studies
Babaliari, E., Ranella, A., & Stratakis, E. (2023) · Bioengineering · doi:10.3390/bioengineering10080902 · Cited by 13
Emerging microfluidics for bioreactor
Chen, H., Fang, Y., Luo, Z., Wang, Y., Sun, W., & Zhao, Y. (2025) · Materials Today · doi:10.1016/j.mattod.2025.03.009 · Cited by 13
Weller, A., Hansen, M. B., Marie, R., Hundahl, A. C., Hempel, C., Kempen, P. J., Frandsen, H. L., Parhamifar, L., Larsen, J. B., & Andresen, T. L. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.965200 · Cited by 13
Ueno, R., Kuninori, M., Sumi, T., Sadeghian, R. B., Takata, Y., Iguchi, A., Tsuda, M., Yamashita, F., Ichikawa, K., & Yokokawa, R. (2023) · Micromachines · doi:10.3390/mi14040761 · Cited by 13
Efficient Low Shear Flow-based Trapping of Biological Entities
Kashani, A. S., & Packirisamy, M. (2019) · Scientific Reports · doi:10.1038/s41598-019-41938-z · Cited by 13
Open Fluidics: A Cell Culture Flow System Developed Over Wettability Contrast‐Based Chips
Oliveira, N. M., Reis, R. L., & Mano, J. F. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700638 · Cited by 13
Yang, Y., Yang, H., Kiskin, F. N., & Zhang, J. Z. (2024) · Medical Review · doi:10.1515/mr-2023-0059 · Cited by 12
Development of a Widely Accessible, Advanced Large-Scale Microfluidic Airway-on-Chip
Rae, B., Vasse, G. F., Amroabadi, J. M., van den Berge, M., Pouwels, S. D., & Heijink, I. H. (2025) · Bioengineering · doi:10.3390/bioengineering12020182 · Cited by 12
Cellular deformation characterization of human breast cancer cells under hydrodynamic forces
Kashani, A. S., & Packirisamy, M. (2017) · AIMS Biophysics · doi:10.3934/biophy.2017.3.400 · Cited by 12
Ching, T., van Steen, A. C. I., Gray-Scherr, D., Teo, J. L., Vasan, A., Jeon, J., Shah, J., Patel, A., Stoddard, A. E., Bays, J., et al. (2025) · Lab on a Chip · doi:10.1039/d4lc00970c · Cited by 11
Zhu, H., Özkayar, G., Lötters, J. C., Tichem, M., & Ghatkesar, M. K. (2023) · Biomedical Microdevices · doi:10.1007/s10544-023-00657-z · Cited by 11
Simulation of hypoxia of myocardial cells in microfluidic systems
Kobuszewska, A., Jastrzębska, E., Żukowski, K., & Brzózka, Z. (2020) · Scientific Reports · doi:10.1038/s41598-020-72660-w · Cited by 11
Wang, C., Xu, N., Yang, Y., Wu, Q., Pang, D., & Zhang, Z. (2017) · Integrative Biology · doi:10.1039/c7ib00151g · Cited by 10
Bourguignon, N., Alessandrello, M. J., Booth, R., Lobo, C. B., Tomás, M. S. J., Cumbal, L. H., Pérez, M., Bhansali, S., Ferrero, M. A., & Lerner, B. (2022) · Chemosphere · doi:10.1016/j.chemosphere.2022.135001 · Cited by 10
Metadata
- Authors
- Shemesh, J., Jalilian, I., Shi, A., Heng Yeoh, G., Knothe Tate, M. L., & Ebrahimi Warkiani, M.
- Affiliations
- UNSW Sydney (AU)
- School of Mechanical and Manufacturing Engineering
- Graduate School of Biomedical Engineering
- ORCID
- Shemesh, Jonathan
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2015
- Volume
- 15
- Issue
- 21
- Pages
- 4114-4127
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1872647657
- Cited by
- 144
- References
- 166
- Citations by year
- 2026: 7 · 2025: 13 · 2024: 11 · 2023: 13 · 2022: 15 · 2021: 17 · 2020: 16 · 2019: 13 · 2018: 10 · 2017: 16 · 2016: 11 · 2015: 2
- FWCI
- 1.30
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Keywords
- flow-induced stress, adherent cells, microfluidics, mechanobiology, shear flow, cell-matrix adhesion, endothelial cell alignment, parallel plate flow chamber
- MeSH terms
- Animals, Cell Adhesion, Humans, Stress, Mechanical, Mechanotransduction, Cellular, Lab-On-A-Chip Devices, Hydrodynamics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.