Flow-induced stress on adherent cells in microfluidic devices
The DOI matches its Crossref record; 166 of the 166 references it cites were found in a registry or an index.
Abstract
The article describes flow-induced stress on adherent cells in microfluidics devices in light of ongoing discoveries in mechanobiology.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Edge effects and high shear stress can also affect the performance and consistency of the device by hindering laminar fl ow in channels, which can harm cells and/or affect their distribution, resulting in inconsistent results which may compromise the predictive value of the platform [68].”
From 3D In Vitro Model (R)evolution: Unveiling Tumor–Stroma Interactions (2021) · cites this paper as [68]
Citations
Cites
Matrix elasticity directs stem cell lineage specification
Engler, A. J., Sen, S., Sweeney, H. L., & Discher, D. E. (2006) · Cell · doi:10.1016/j.cell.2006.06.044 · Cited by 13,915
Endothelium-derived relaxing factor produced and released from artery and vein is nitric oxide.
Ignarro, L. J., Buga, G. M., Wood, K. S., Byrns, R. E., & Chaudhuri, G. (1987) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.84.24.9265 · Cited by 5,074
Geometric Control of Cell Life and Death
Chen, C. S., Mrksich, M., Huang, S., Whitesides, G. M., & Ingber, D. E. (1997) · Science · doi:10.1126/science.276.5317.1425 · Cited by 4,657
Kalluri, R., & Zeisberg, M. (2006) · Nature Reviews Cancer · doi:10.1038/nrc1877 · Cited by 4,538
Angiogenesis in health and disease
Carmeliet, P. (2003) · Nature Medicine · doi:10.1038/nm0603-653 · Cited by 4,276
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Fang, J., Nakamura, H., & Maeda, H. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.04.009 · Cited by 3,559
Mechanotransduction Across the Cell Surface and Through the Cytoskeleton
Wang, N., Butler, J. P., & Ingber, D. E. (1993) · Science · doi:10.1126/science.7684161 · Cited by 3,003
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Maeda, H., Nakamura, H., & Fang, J. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.10.002 · Cited by 2,376
High Interstitial Fluid Pressure - an Obstacle in Cancer Therapy
Heldin, C.-H., Rubin, K., Pietras, K., & Östman, A. (2004) · Nature reviews. Cancer · doi:10.1038/nrc1456 · Cited by 2,222
Polycystins 1 and 2 mediate mechanosensation in the primary cilium of kidney cells
Nauli, S. M., Alenghat, F. J., Luo, Y., Williams, E., Vassilev, P., Li, X., Elia, A. E. H., Lu, W., Brown, E. M., Quinn, S. J., et al. (2003) · Nature Genetics · doi:10.1038/ng1076 · Cited by 2,057
Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
A mechanosensory complex that mediates the endothelial cell response to fluid shear stress
Tzima, E., Irani-Tehrani, M., Kiosses, W. B., Dejana, E., Schultz, D. A., Engelhardt, B., Cao, G., DeLisser, H., & Schwartz, M. A. (2005) · Nature · doi:10.1038/nature03952 · Cited by 1,711
Zarins, C. K., Giddens, D. P., Bharadvaj, B. K., Sottiurai, V. S., Mabon, R. F., & Glagov, S. (1983) · Circulation Research · doi:10.1161/01.res.53.4.502 · Cited by 1,485
Engineering cell shape and function
Singhvi, R., Kumar, A., Lopez, G. P., Stephanopoulos, G. N., Wang, D. I. C., Whitesides, G. M., & Ingber, D. E. (1994) · Science · doi:10.1126/science.8171320 · Cited by 1,453
Homing and cellular traffic in lymph nodes
von Andrian, U. H., & Mempel, T. R. (2003) · Nature Reviews Immunology · doi:10.1038/nri1222 · Cited by 1,281
Ausprunk, D. H., & Folkman, J. (1977) · Microvascular Research · doi:10.1016/0026-2862(77)90141-8 · Cited by 1,281
Mechanotransduction in vascular physiology and atherogenesis
Hahn, C., & Schwartz, M. A. (2009) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2596 · Cited by 1,211
Three-dimensional microfluidic model for tumor cell intravasation and endothelial barrier function
Zervantonakis, I. K., Hughes-Alford, S. K., Charest, J. L., Condeelis, J. S., Gertler, F. B., & Kamm, R. D. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1210182109 · Cited by 872
Engineering of functional, perfusable 3D microvascular networks on a chip
Kim, S., Lee, H., Chung, M., & Jeon, N. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41320a · Cited by 872
A shear gradient–dependent platelet aggregation mechanism drives thrombus formation
Nesbitt, W. S., Westein, E., Tovar-Lopez, F. J., Tolouei, E., Mitchell, A., Fu, J., Carberry, J., Fouras, A., & Jackson, S. P. (2009) · Nature Medicine · doi:10.1038/nm.1955 · Cited by 862
An extracellular matrix microarray for probing cellular differentiation
Flaim, C. J., Chien, S., & Bhatia, S. N. (2005) · Nature Methods · doi:10.1038/nmeth736 · Cited by 803
Characterization of a microfluidic in vitro model of the blood-brain barrier (μBBB)
Booth, R., & Kim, H. (2012) · Lab on a Chip · doi:10.1039/c2lc40094d · Cited by 739
Centrifugal microfluidics for biomedical applications
Gorkin, R., Park, J., Siegrist, J., Amasia, M., Lee, B. S., Park, J.-M., Kim, J., Kim, H., Madou, M., & Cho, Y.-K. (2010) · Lab on a Chip · doi:10.1039/b924109d · Cited by 731
Mechanism of shape determination in motile cells
Keren, K., Pincus, Z., Allen, G. M., Barnhart, E. L., Marriott, G., Mogilner, A., & Theriot, J. A. (2008) · Nature · doi:10.1038/nature06952 · Cited by 719
The Regulation of Natural Anticoagulant Pathways
Esmon, C. T. (1987) · Science · doi:10.1126/science.3029867 · Cited by 697
Mechanotransduction and flow across the endothelial glycocalyx
Weinbaum, S., Zhang, X., Han, Y., Vink, H., & Cowin, S. C. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1332808100 · Cited by 579
Prager-Khoutorsky, M., Lichtenstein, A., Krishnan, R., Rajendran, K., Mayo, A., Kam, Z., Geiger, B., & Bershadsky, A. D. (2011) · Nature Cell Biology · doi:10.1038/ncb2370 · Cited by 564
Mechanotransduction in Response to Shear Stress
Chen, K.-D., Li, Y.-S., Kim, M., Li, S., Yuan, S., Chien, S., & Shyy, J. Y.-J. (1999) · Journal of Biological Chemistry · doi:10.1074/jbc.274.26.18393 · Cited by 559
Karagiannis, G. S., Poutahidis, T., Erdman, S. E., Kirsch, R., Riddell, R. H., & Diamandis, E. P. (2012) · Molecular Cancer Research · doi:10.1158/1541-7786.mcr-12-0307 · Cited by 507
Fluid forces control endothelial sprouting
Song, J. W., & Munn, L. L. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1105316108 · Cited by 498
A multi-layer microfluidic device for efficient culture and analysis of renal tubular cells
Jang, K.-J., & Suh, K.-Y. (2010) · Lab Chip · doi:10.1039/b907515a · Cited by 497
Provenzano, P. P., & Keely, P. J. (2011) · Journal of Cell Science · doi:10.1242/jcs.067009 · Cited by 494
Huh, D., Fujioka, H., Tung, Y.-C., Futai, N., Paine, R., Grotberg, J. B., & Takayama, S. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0610868104 · Cited by 492
A practical guide to microfluidic perfusion culture of adherent mammalian cells
Kim, L., Toh, Y.-C., Voldman, J., & Yu, H. (2007) · Lab on a Chip · doi:10.1039/b704602b · Cited by 455
Fluid Shear Stress Activation of Focal Adhesion Kinase
Li, S., Kim, M., Hu, Y.-L., Jalali, S., Schlaepfer, D. D., Hunter, T., Chien, S., & Shyy, J. Y.-J. (1997) · Journal of Biological Chemistry · doi:10.1074/jbc.272.48.30455 · Cited by 414
Microengineered Platforms for Cell Mechanobiology
Kim, D.-H., Wong, P. K., Park, J., Levchenko, A., & Sun, Y. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124915 · Cited by 411
Microfluidic Shear Devices for Quantitative Analysis of Cell Adhesion
Lu, H., Koo, L. Y., Wang, W. M., Lauffenburger, D. A., Griffith, L. G., & Jensen, K. F. (2004) · Analytical Chemistry · doi:10.1021/ac049837t · Cited by 405
Saharinen, P., Tammela, T., Karkkainen, M. J., & Alitalo, K. (2004) · Trends in Immunology · doi:10.1016/j.it.2004.05.003 · Cited by 391
Jin, Z.-G., Ueba, H., Tanimoto, T., Lungu, A. O., Frame, M. D., & Berk, B. C. (2003) · Circulation Research · doi:10.1161/01.res.0000089257.94002.96 · Cited by 388
Micro-Particle Image Velocimetry (µPIV): Recent developments, applications, and guidelines
Lindken, R., Rossi, M., Große, S., & Westerweel, J. (2009) · Lab on a Chip · doi:10.1039/b906558j · Cited by 387
Kapur, S., Baylink, D. J., & William Lau, K.-H. (2003) · Bone · doi:10.1016/s8756-3282(02)00979-1 · Cited by 364
Flow-induced deformation of shallow microfluidic channels
Gervais, T., El-Ali, J., Günther, A., & Jensen, K. F. (2006) · Lab on a Chip · doi:10.1039/b513524a · Cited by 359
Lecault, V., VanInsberghe, M., Sekulovic, S., Knapp, D. J. H. F., Wohrer, S., Bowden, W., Viel, F., McLaughlin, T., Jarandehei, A., Miller, M., et al. (2011) · Nature Methods · doi:10.1038/nmeth.1614 · Cited by 335
Endothelial mechanotransduction, nitric oxide and vascular inflammation
HARRISON, D. G., WIDDER, J., GRUMBACH, I., CHEN, W., WEBER, M., & SEARLES, C. (2006) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.2006.01621.x · Cited by 334
AbouAlaiwi, W. A., Takahashi, M., Mell, B. R., Jones, T. J., Ratnam, S., Kolb, R. J., & Nauli, S. M. (2009) · Circulation Research · doi:10.1161/circresaha.108.192765 · Cited by 327
Gravity-Driven Microfluidic Particle Sorting Device with Hydrodynamic Separation Amplification
Huh, D., Bahng, J. H., Ling, Y., Wei, H.-H., Kripfgans, O. D., Fowlkes, J. B., Grotberg, J. B., & Takayama, S. (2007) · Analytical Chemistry · doi:10.1021/ac061542n · Cited by 315
Osawa, M., Masuda, M., Kusano, K.-I., & Fujiwara, K. (2002) · The Journal of Cell Biology · doi:10.1083/jcb.200205049 · Cited by 307
Westein, E., van der Meer, A. D., Kuijpers, M. J. E., Frimat, J.-P., van den Berg, A., & Heemskerk, J. W. M. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1209905110 · Cited by 304
A driving force for change: interstitial flow as a morphoregulator
Rutkowski, J. M., & Swartz, M. A. (2007) · Trends in Cell Biology · doi:10.1016/j.tcb.2006.11.007 · Cited by 302
Fluid Shear Stress Stimulates Mitogen-Activated Protein Kinase in Endothelial Cells
Tseng, H., Peterson, T. E., & Berk, B. C. (1995) · Circulation Research · doi:10.1161/01.res.77.5.869 · Cited by 288
A positive feedback mechanism governs the polarity and motion of motile cilia
Mitchell, B., Jacobs, R., Li, J., Chien, S., & Kintner, C. (2007) · Nature · doi:10.1038/nature05771 · Cited by 285
Microfluidic platforms for mechanobiology
Polacheck, W. J., Li, R., Uzel, S. G. M., & Kamm, R. D. (2013) · Lab on a Chip · doi:10.1039/c3lc41393d · Cited by 272
Stimulation of Transcription Factors NFκB and AP1 in Endothelial Cells Subjected to Shear Stress
Lan, Q. X., Mercurius, K. O., & Davies, P. F. (1994) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.1994.1794 · Cited by 266
Mechanotransduction of fluid stresses governs 3D cell migration
Polacheck, W. J., German, A. E., Mammoto, A., Ingber, D. E., & Kamm, R. D. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1316848111 · Cited by 265
Shear Stress Activates p60src-Ras-MAPK Signaling Pathways in Vascular Endothelial Cells
Jalali, S., Li, Y.-S., Sotoudeh, M., Yuan, S., Li, S., Chien, S., & Shyy, J. Y.-J. (1998) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.18.2.227 · Cited by 240
A microfluidic processor for gene expression profiling of single human embryonic stem cells
Zhong, J. F., Chen, Y., Marcus, J. S., Scherer, A., Quake, S. R., Taylor, C. R., & Weiner, L. P. (2008) · Lab Chip · doi:10.1039/b712116d · Cited by 234
Rizvi, I., Gurkan, U. A., Tasoglu, S., Alagic, N., Celli, J. P., Mensah, L. B., Mai, Z., Demirci, U., & Hasan, T. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1216989110 · Cited by 234
Vascular endothelial responses to altered shear stress: Pathologic implications for atherosclerosis
Chiu, J.-J., Usami, S., & Chien, S. (2009) · Annals of Medicine · doi:10.1080/07853890802186921 · Cited by 226
MAP Kinase Activation by Flow in Endothelial Cells: Role of β1 Integrins and Tyrosine Kinases
Ishida, T., Peterson, T. E., Kovach, N. L., & Berk, B. C. (1996) · Circulation Research · doi:10.1161/01.res.79.2.310 · Cited by 226
Single-cell response to stiffness exhibits muscle-like behavior
Mitrossilis, D., Fouchard, J., Guiroy, A., Desprat, N., Rodriguez, N., Fabry, B., & Asnacios, A. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0903994106 · Cited by 225
Ebong, E. E., Lopez-Quintero, S. V., Rizzo, V., Spray, D. C., & Tarbell, J. M. (2014) · Integr. Biol. · doi:10.1039/c3ib40199e · Cited by 217
Macro- and microscale fluid flow systems for endothelial cell biology
Young, E. W. K., & Simmons, C. A. (2010) · Lab Chip · doi:10.1039/b913390a · Cited by 215
Electroosmotic Flow in Microchannels
Yang, R.-J., Fu, L.-M., & Lin, Y.-C. (2001) · Journal of Colloid and Interface Science · doi:10.1006/jcis.2001.7551 · Cited by 211
Microfluidic very large scale integration (mVLSI) with integrated micromechanical valves
Araci, I. E., & Quake, S. R. (2012) · Lab on a Chip · doi:10.1039/c2lc40258k · Cited by 209
The deformation of flexible PDMS microchannels under a pressure driven flow
Hardy, B. S., Uechi, K., Zhen, J., & Pirouz Kavehpour, H. (2009) · Lab Chip · doi:10.1039/b813061b · Cited by 203
Twisting integrin receptors increases endothelin-1 gene expression in endothelial cells
Chen, J., Fabry, B., Schiffrin, E. L., & Wang, N. (2001) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.2001.280.6.c1475 · Cited by 200
Distinct roles for the small GTPases Cdc42 and Rho in endothelial responses to shear stress
Li, S., Chen, B. P. C., Azuma, N., Hu, Y.-L., Wu, S. Z., Sumpio, B. E., Shyy, J. Y.-J., & Chien, S. (1999) · Journal of Clinical Investigation · doi:10.1172/jci5367 · Cited by 191
Flow rate analysis of a surface tension driven passive micropump
Berthier, E., & Beebe, D. J. (2007) · Lab on a Chip · doi:10.1039/b707637a · Cited by 191
An ultra-high-throughput spiral microfluidic biochip for the enrichment of circulating tumor cells
Warkiani, M. E., Khoo, B. L., Tan, D. S.-W., Bhagat, A. A. S., Lim, W.-T., Yap, Y. S., Lee, S. C., Soo, R. A., Han, J., & Lim, C. T. (2014) · The Analyst · doi:10.1039/c4an00355a · Cited by 191
Pumps for microfluidic cell culture
Byun, C. K., Abi‐Samra, K., Cho, Y., & Takayama, S. (2014) · ELECTROPHORESIS · doi:10.1002/elps.201300205 · Cited by 187
Primary cilia sensitize endothelial cells for fluid shear stress
Hierck, B. P., Van der Heiden, K., Alkemade, F. E., Van de Pas, S., Van Thienen, J. V., Groenendijk, B. C. W., Bax, W. H., Van der Laarse, A., DeRuiter, M. C., Horrevoets, A. J. G., et al. (2008) · Developmental Dynamics · doi:10.1002/dvdy.21472 · Cited by 187
Mining the microbial dark matter
Lok, C. (2015) · Nature · doi:10.1038/522270a · Cited by 183
Integrating biological vasculature into a multi-organ-chip microsystem
Schimek, K., Busek, M., Brincker, S., Groth, B., Hoffmann, S., Lauster, R., Lindner, G., Lorenz, A., Menzel, U., Sonntag, F., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50217a · Cited by 180
Tumor Cell Invasion Is Promoted by Interstitial Flow-Induced Matrix Priming by Stromal Fibroblasts
Shieh, A. C., Rozansky, H. A., Hinz, B., & Swartz, M. A. (2011) · Cancer Research · doi:10.1158/0008-5472.can-10-1513 · Cited by 177
Wang, X.-Y., Jin, Z.-H., Gan, B.-W., Lv, S.-W., Xie, M., & Huang, W.-H. (2014) · Lab Chip · doi:10.1039/c4lc00069b · Cited by 166
A microfluidic flow-stretch chip for investigating blood vessel biomechanics
Zheng, W., Jiang, B., Wang, D., Zhang, W., Wang, Z., & Jiang, X. (2012) · Lab on a Chip · doi:10.1039/c2lc40173h · Cited by 165
Berk, B. C., Corson, M. A., Peterson, T. E., & Tseng, H. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00092-5 · Cited by 158
Releasing Pressure in Tumors: What Do We Know So Far and Where Do We Go from Here? A Review
Ariffin, A. B., Forde, P. F., Jahangeer, S., Soden, D. M., & Hinchion, J. (2014) · Cancer Research · doi:10.1158/0008-5472.can-13-3696 · Cited by 150
Control of arterial branching morphogenesis in embryogenesis: go with the flow
LENOBLE, F., FLEURY, V, PRIES, A., CORVOL, P., EICHMANN, A., & RENEMAN, R. (2005) · Cardiovascular Research · doi:10.1016/j.cardiores.2004.09.018 · Cited by 150
Tarbell, J. M., & Ebong, E. E. (2008) · Science Signaling · doi:10.1126/scisignal.140pt8 · Cited by 145
Microfabricated perfusable cardiac biowire: a platform that mimics native cardiac bundle
Xiao, Y., Zhang, B., Liu, H., Miklas, J. W., Gagliardi, M., Pahnke, A., Thavandiran, N., Sun, Y., Simmons, C., Keller, G., et al. (2014) · Lab Chip · doi:10.1039/c3lc51123e · Cited by 144
A biomimetic multicellular model of the airways using primary human cells
Sellgren, K. L., Butala, E. J., Gilmour, B. P., Randell, S. H., & Grego, S. (2014) · Lab Chip · doi:10.1039/c4lc00552j · Cited by 143
A quantitative microfluidic angiogenesis screen for studying anti-angiogenic therapeutic drugs
Kim, C., Kasuya, J., Jeon, J., Chung, S., & Kamm, R. D. (2015) · Lab on a Chip · doi:10.1039/c4lc00866a · Cited by 143
Vickerman, V., & Kamm, R. D. (2012) · Integrative Biology · doi:10.1039/c2ib00184e · Cited by 136
Bubbles no more: in-plane trapping and removal of bubbles in microfluidic devices
Lochovsky, C., Yasotharan, S., & Günther, A. (2011) · Lab on a Chip · doi:10.1039/c1lc20817a · Cited by 134
Roles of cell confluency and fluid shear in 3-dimensional intracellular forces in endothelial cells
Hur, S. S., del Álamo, J. C., Park, J. S., Li, Y.-S., Nguyen, H. A., Teng, D., Wang, K.-C., Flores, L., Alonso-Latorre, B., Lasheras, J. C., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1207326109 · Cited by 129
Regulation of tumor invasion by interstitial fluid flow
Shieh, A. C., & Swartz, M. A. (2011) · Physical Biology · doi:10.1088/1478-3975/8/1/015012 · Cited by 126
Controlled electromechanical cell stimulation on-a-chip
Pavesi, A., Adriani, G., Rasponi, M., Zervantonakis, I. K., Fiore, G. B., & Kamm, R. D. (2015) · Scientific Reports · doi:10.1038/srep11800 · Cited by 125
Mechanical modulation of osteochondroprogenitor cell fate
Tate, M. L. K., Falls, T. D., McBride-Gagyi, S. H., Atit, R. P., & Knothe, U. R. (2008) · The International Journal of Biochemistry & Cell Biology · doi:10.1016/j.biocel.2008.05.011 · Cited by 123
Cassuto, J., Dou, H., Czikora, I., Szabo, A., Patel, V. S., Kamath, V., Belin de Chantemele, E., Feher, A., Romero, M. J., & Bagi, Z. (2014) · Diabetes · doi:10.2337/db13-0577 · Cited by 122
Shear stress activates Tie2 receptor tyrosine kinase in human endothelial cells
Lee, H. J., & Koh, G. Y. (2003) · Biochemical and Biophysical Research Communications · doi:10.1016/s0006-291x(03)00592-8 · Cited by 120
Molecular Regulation of Lymphatic Contractility
Muthuchamy, M., & Zawieja, D. (2008) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1413.008 · Cited by 119
Toh, Y., & Voldman, J. (2011) · The FASEB Journal · doi:10.1096/fj.10-168971 · Cited by 119
A novel multishear microdevice for studying cell mechanics
Chau, L., Doran, M., & Cooper-White, J. (2009) · Lab on a Chip · doi:10.1039/b823180j · Cited by 117
Xu, J., Vaillant, R., & Attinger, D. (2010) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0592-5 · Cited by 116
The Relationship between Tumor Blood Flow, Angiogenesis, Tumor Hypoxia, and Aerobic Glycolysis
Østergaard, L., Tietze, A., Nielsen, T., Drasbek, K. R., Mouridsen, K., Jespersen, S. N., & Horsman, M. R. (2013) · Cancer Research · doi:10.1158/0008-5472.can-13-0964 · Cited by 113
Characterization of syringe-pump-driven induced pressure fluctuations in elastic microchannels
Zeng, W., Jacobi, I., Beck, D. J., Li, S., & Stone, H. A. (2014) · Lab on a Chip · doi:10.1039/c4lc01347f · Cited by 112
Park, J. Y., Hwang, C. M., Lee, S. H., & Lee, S.-H. (2007) · Lab on a Chip · doi:10.1039/b710777c · Cited by 109
Modulation of Stem Cell Shape and Fate B: Mechanical Modulation of Cell Shape and Gene Expression
McBride-Gagyi, S. H., Falls, T. D., & Tate, M. L. K. (2008) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0113 · Cited by 105
Li, M., Ku, D. N., & Forest, C. R. (2012) · Lab on a Chip · doi:10.1039/c2lc21145a · Cited by 105
Hegde, M., Jindal, R., Bhushan, A., Bale, S. S., McCarty, W. J., Golberg, I., Usta, O. B., & Yarmush, M. L. (2014) · Lab Chip · doi:10.1039/c4lc00071d · Cited by 104
Effects of shear stress on endothelial cell haptotaxis on micropatterned surfaces
Hsu, S. H., Thakar, R. G., Liepmann, D., & Li, S. (2005) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2005.08.272 · Cited by 104
Circumventing air bubbles in microfluidic systems and quantitative continuous-flow PCR applications
Nakayama, T., Kurosawa, Y., Furui, S., Kerman, K., Kobayashi, M., Rao, S. R., Yonezawa, Y., Nakano, K., Hino, A., Yamamura, S., et al. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0688-7 · Cited by 103
Booth, R., Noh, S., & Kim, H. (2014) · Lab on a Chip · doi:10.1039/c3lc51304a · Cited by 102
Lam, R. H. W., Sun, Y., Chen, W., & Fu, J. (2012) · Lab on a Chip · doi:10.1039/c2lc21146g · Cited by 93
Frohlich, E. M., Zhang, X., & Charest, J. L. (2011) · Integrative Biology · doi:10.1039/c1ib00096a · Cited by 91
Contractile forces regulate cell division in three-dimensional environments
Lesman, A., Notbohm, J., Tirrell, D. A., & Ravichandran, G. (2014) · The Journal of Cell Biology · doi:10.1083/jcb.201309029 · Cited by 91
MEMS sensors and microsystems for cell mechanobiology
Rajagopalan, J., & Saif, M. T. A. (2011) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/21/5/054002 · Cited by 91
Mark, D., Metz, T., Haeberle, S., Lutz, S., Ducrée, J., Zengerle, R., & von Stetten, F. (2009) · Lab on a Chip · doi:10.1039/b914415c · Cited by 89
Tsou, J. K., Gower, R. M., Ting, H. J., Schaff, U. Y., Insana, M. F., Passerini, A. G., & Simon, S. I. (2008) · Microcirculation · doi:10.1080/10739680701724359 · Cited by 86
Detachment of captured cancer cells under flow acceleration in a bio-functionalized microchannel
Cheung, L. S. L., Zheng, X., Stopa, A., Baygents, J. C., Guzman, R. Z., Schroeder, J. A., Heimark, R. L., & Zohar, Y. (2009) · Lab on a Chip · doi:10.1039/b822172c · Cited by 85
Yu, W., Qu, H., Hu, G., Zhang, Q., Song, K., Guan, H., Liu, T., & Qin, J. (2014) · PLoS ONE · doi:10.1371/journal.pone.0089966 · Cited by 80
Chen, H., Cornwell, J. A., Zhang, H., Lim, T., Resurreccion, R., Port, T., Rosengarten, G., & Nordon, R. E. (2013) · Lab on a Chip · doi:10.1039/c3lc50123j · Cited by 80
A parametric study of human fibroblasts culture in a microchannel bioreactor
Korin, N., Bransky, A., Dinnar, U., & Levenberg, S. (2007) · Lab on a Chip · doi:10.1039/b702392h · Cited by 77
Electronic control of elastomeric microfluidic circuits with shape memory actuators
Vyawahare, S., Sitaula, S., Martin, S., Adalian, D., & Scherer, A. (2008) · Lab on a Chip · doi:10.1039/b804515a · Cited by 76
Optimal periodic perfusion strategy for robust long-term microfluidic cell culture
Giulitti, S., Magrofuoco, E., Prevedello, L., & Elvassore, N. (2013) · Lab on a Chip · doi:10.1039/c3lc50643f · Cited by 74
Muthard, R. W., & Diamond, S. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41332b · Cited by 73
Emerging trends in the pathophysiology of lymphatic contractile function
Chakraborty, S., Davis, M. J., & Muthuchamy, M. (2015) · Seminars in Cell & Developmental Biology · doi:10.1016/j.semcdb.2015.01.005 · Cited by 73
Hydrodynamic effects on bacterial biofilm development in a microfluidic environment
Kim, J., Kim, H.-S., Han, S., Lee, J.-Y., Oh, J.-E., Chung, S. H., & Park, H. (2013) · Lab on a Chip · doi:10.1039/c3lc40802g · Cited by 72
Rossi, M., Lindken, R., Hierck, B. P., & Westerweel, J. (2009) · Lab on a Chip · doi:10.1039/b822270n · Cited by 71
Kalashnikov, M., Lee, J. C., Campbell, J., Sharon, A., & Sauer-Budge, A. F. (2012) · Lab on a Chip · doi:10.1039/c2lc40531h · Cited by 70
Yu, J. Q., Liu, X. F., Chin, L. K., Liu, A. Q., & Luo, K. Q. (2013) · Lab on a Chip · doi:10.1039/c3lc50105a · Cited by 70
Song, M. J., Brady‐Kalnay, S. M., McBride-Gagyi, S. H., Phillips‐Mason, P. J., Dean, D., & Tate, M. L. K. (2012) · PLoS ONE · doi:10.1371/journal.pone.0043601 · Cited by 65
Rotenberg, M. Y., Ruvinov, E., Armoza, A., & Cohen, S. (2012) · Lab on a Chip · doi:10.1039/c2lc40144d · Cited by 65
Anderson, E. J., Falls, T. D., Sorkin, A. M., & Tate, M. L. K. (2006) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-5-27 · Cited by 64
Evans, S. F., Docheva, D., Bernecker, A., Colnot, C., Richter, R. P., & Tate, M. L. K. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.09.024 · Cited by 61
Probing Cellular Dynamics with a Chemical Signal Generator
Kuczenski, B., Ruder, W. C., MESSNER, W. C., & LeDuc, P. R. (2009) · PLoS ONE · doi:10.1371/journal.pone.0004847 · Cited by 60
A multichannel dampened flow system for studies on shear stress-mediated mechanotransduction
Voyvodic, P. L., Min, D., & Baker, A. B. (2012) · Lab on a Chip · doi:10.1039/c2lc40526a · Cited by 57
Testing Aβ toxicity on primary CNS cultures using drug-screening microfluidic chips
Ruiz, A., Joshi, P., Mastrangelo, R., Francolini, M., Verderio, C., & Matteoli, M. (2014) · Lab on a Chip · doi:10.1039/c4lc00174e · Cited by 55
Mechanical modulation of nascent stem cell lineage commitment in tissue engineering scaffolds
Song, M. J., Dean, D., & Tate, M. L. K. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.04.023 · Cited by 54
RhoA mediates flow-induced endothelial sprouting in a 3-D tissue analogue of angiogenesis
Song, J. W., Daubriac, J., Tse, J. M., Bazou, D., & Munn, L. L. (2012) · Lab on a Chip · doi:10.1039/c2lc40389g · Cited by 54
Hattori, K., Munehira, Y., Kobayashi, H., Satoh, T., Sugiura, S., & Kanamori, T. (2014) · Journal of Bioscience and Bioengineering · doi:10.1016/j.jbiosc.2014.02.006 · Cited by 53
Oscillatory shear stress induced calcium flickers in osteoblast cells
Roy, B., Das, T., Mishra, D., Maiti, T. K., & Chakraborty, S. K. (2013) · Integrative Biology · doi:10.1039/c3ib40174j · Cited by 53
Induced charge electroosmosis micropumps using arrays of Janus micropillars
Paustian, J. S., Pascall, A. J., Wilson, N. M., & Squires, T. M. (2014) · Lab on a Chip · doi:10.1039/c4lc00141a · Cited by 52
Shao, Y., Mann, J. M., Chen, W., & Fu, J. (2014) · Integrative Biology · doi:10.1039/c3ib40223a · Cited by 52
Active liquid degassing in microfluidic systems
Karlsson, J. M., Gazin, M., Laakso, S., Haraldsson, T., Malhotra‐Kumar, S., Mäki, M., Goossens, H., & van der Wijngaart, W. (2013) · Lab on a Chip · doi:10.1039/c3lc50778e · Cited by 51
Biophysical regulation of stem cell behavior within the niche
Conway, A., & Schaffer, D. V. (2012) · Stem Cell Research & Therapy · doi:10.1186/scrt141 · Cited by 51
Blood-flow sensing by anionic biopolymers
Siegel, G., Malmsten, M., Klüßendorf, D., Walter, A., Schnalke, F., & Kauschmann, A. (1996) · Journal of the Autonomic Nervous System · doi:10.1016/0165-1838(95)00071-2 · Cited by 47
Human follicular dendritic cells and fibroblasts share the 3C8 antigen
Lee, I. Y., & Choe, J. (2003) · Biochemical and Biophysical Research Communications · doi:10.1016/s0006-291x(03)00649-1 · Cited by 46
Pumpless steady-flow microfluidic chip for cell culture
Marimuthu, M., & Kim, S. (2013) · Analytical Biochemistry · doi:10.1016/j.ab.2013.02.007 · Cited by 44
Sorkin, A. M., Dee, K. C., & Tate, M. L. K. (2004) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00059.2004 · Cited by 44
Sinha, R., Gac, S. L., Verdonschot, N. J. J., van den Berg, A., Koopman, H. F. J. M., & Rouwkema, J. (2014) · Lab on a Chip · doi:10.1039/c4lc01259c · Cited by 44
Anderson, E. J., & Tate, M. L. K. (2007) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-6-46 · Cited by 43
Wang, G., Ho, H., Chen, Q., Yang, A. K. L., Kwok, H.-C., Wu, S.-Y., Kong, S., Kwan, Y. W., & Zhang, X. (2013) · Lab on a Chip · doi:10.1039/c3lc50545f · Cited by 42
Kalchman, J., Fujioka, S., Chung, S. H., Kikkawa, Y., Mitaka, T., Kamm, R. D., Tanishita, K., & Sudo, R. (2012) · Microfluidics and Nanofluidics · doi:10.1007/s10404-012-1104-6 · Cited by 40
A microfluidic device for continuous cancer cell culture and passage with hydrodynamic forces
Liu, L., Loutherback, K., Liao, D., Yeater, D. B., Lambert, G., Estevez‐Torres, A., Sturm, J. C., Getzenberg, R. H., & Austin, R. H. (2010) · Lab on a Chip · doi:10.1039/c003509b · Cited by 39
Wang, L., Zhang, Z.-L., Wdzieczak-Bakala, J., Pang, D.-W., Liu, J., & Chen, Y. (2011) · Lab on a Chip · doi:10.1039/c1lc20722a · Cited by 37
Collaborative effects of electric field and fluid shear stress on fibroblast migration
Song, S., Han, H., Ko, U. H., Kim, J., & Shin, J. H. (2013) · Lab on a Chip · doi:10.1039/c3lc41240g · Cited by 37
MAEDA, E., Hagiwara, Y., Wang, J. H., & OHASHI, T. (2013) · Biomedical Microdevices · doi:10.1007/s10544-013-9798-0 · Cited by 37
Garza-García, L. D., García‐López, E., Camacho-León, S., Rocha-Pizaña, M. D. R., López‐Pacheco, F., López-Meza, J., Araíz-Hernández, D., Tapia-Mejía, E. J., Santiago, G. T., Rodriguez, C. A., et al. (2014) · Lab on a Chip · doi:10.1039/c3lc51301g · Cited by 36
Schwemmer, F., Hutzenlaub, T., Buselmeier, D., Paust, N., von Stetten, F., Mark, D., Zengerle, R., & Kosse, D. (2015) · Lab on a Chip · doi:10.1039/c5lc00513b · Cited by 34
DVD technology-based molecular diagnosis platform: quantitative pregnancy test on a disc
Li, X., Weng, S. S. H., Ge, B., Yao, Z., & Yu, H. (2014) · Lab on a Chip · doi:10.1039/c3lc51411k · Cited by 32
A novel tool for dynamic cell adhesion studies – the De-Adhesion Number Investigator DANI
Hartmann, A., Stamp, M. E. M., Kmeth, R., Buchegger, S., Stritzker, B., Saldamli, B., Burgkart, R., Schneider, M. F., & Wixforth, A. (2013) · Lab on a Chip · doi:10.1039/c3lc50916h · Cited by 31
Warkiani, M. E., Lou, C.-P., & Gong, H. (2011) · Biomicrofluidics · doi:10.1063/1.3637630 · Cited by 30
Engineering approaches for inducing blood vessel formation
Blinder, Y. J., Mooney, D. J., & Levenberg, S. (2013) · Current Opinion in Chemical Engineering · doi:10.1016/j.coche.2013.11.003 · Cited by 29
Titles of chemical papers in British and foreign journals
(1850) · Quarterly Journal of the Chemical Society of London · doi:10.1039/qj8500200367 · Cited by 25
Tong, Z., Cheung, L. S.-L., Stebe, K. J., & Κωνσταντόπουλος, Κ. (2012) · Integrative Biology · doi:10.1039/c2ib20036h · Cited by 22
Lakhotiya, H., Mondal, K., Nagarale, R. K., & Sharma, A. (2014) · RSC Advances · doi:10.1039/c4ra04058a · Cited by 20
Walsh, D. I., Sommer, G. J., Schaff, U. Y., Hahn, P., Jaffe, G. J., & Murthy, S. K. (2014) · Lab on a Chip · doi:10.1039/c4lc00279b · Cited by 20
Cell culture using centrifugal microfluidic platform with demonstration on Pichia pastoris
Ren, Y., Chow, L. M. C., & Leung, W. W. (2012) · Biomedical Microdevices · doi:10.1007/s10544-012-9735-7 · Cited by 19
Shyy, J. Y. ‐. (2001) · Biorheology · doi:10.1177/0006355x2001038002003006 · Cited by 17
Well plate-based perfusion culture device for tissue and tumor microenvironment replication
Zhang, W., Gu, Y., Hao, Y., Sun, Q., Konior, K., Wang, H., Zilberberg, J., & Lee, W. Y. (2015) · Lab on a Chip · doi:10.1039/c5lc00341e · Cited by 17
Microfluidic Platforms for Human Disease Cell Mechanics Studies
Majid, E. W., & Lim, C. T. (2013) · Courses and lectures · doi:10.1007/978-3-7091-1574-9_6 · Cited by 8
Research works printed but not linked: 10
- Song, 2010, PLoS One, 5
- Sorkin, 2004, Am. J. Physiol., 287, C1527, 10.1152/ajpcell.00059.2004 · DOI
- Adapala, 2015, Oncogene, 1
- Yamamoto, 2007, Am. J. Physiol., 293, H1646
- Pohl, 1991, Am. J. Physiol., 261, H2016
- Go, 1998, Am. J. Physiol., 275, H1898
- Shyy, 2001, Biorheology, 38, 109
- Huh, 2010, Science, 328, 1662, 10.1126/science.1188302 · DOI · Paper page
- McBride, 2008, Tissue Eng. Part A, 14, 1573, 10.1089/ten.tea.2008.0113 · DOI
- Chang, 2011, Mol. Cell Biomech., 8, 297
Cited by
3D In Vitro Model (R)evolution: Unveiling Tumor–Stroma Interactions
Rodrigues, J., Heinrich, M. A., Teixeira, L. M., & Prakash, J. (2021) · Trends in Cancer · doi:10.1016/j.trecan.2020.10.009 · Cited by 405
“Edge effects and high shear stress can also affect the performance and consistency of the device by hindering laminar flow in channels, which can harm cells and/or affect their distribution, resulting in inconsistent results which may compromise the predictive value of the platform [68].”
BackgroundTumor microenvironment: barrier or opportunity towards effective cancer therapy
Tiwari, A., Trivedi, R., & Lin, S.-Y. (2022) · Journal of Biomedical Science · doi:10.1186/s12929-022-00866-3 · Cited by 377
Microfluidic organ-on-chip technology for blood-brain barrier research
van der Helm, M. W., van der Meer, A. D., Eijkel, J. C. T., van den Berg, A., & Segerink, L. I. (2016) · Tissue Barriers · doi:10.1080/21688370.2016.1142493 · Cited by 333
Tumor microenvironment signaling and therapeutics in cancer progression
Goenka, A., Khan, F., Verma, B., Sinha, P., Dmello, C. C., Jogalekar, M. P., Gangadaran, P., & Ahn, B. (2023) · Cancer Communications · doi:10.1002/cac2.12416 · Cited by 323
Integration of substrate- and flow-derived stresses in endothelial cell mechanobiology
Dessalles, C. A., Leclech, C., Castagnino, A., & Barakat, A. I. (2021) · Communications Biology · doi:10.1038/s42003-021-02285-w · Cited by 230
Metadata
- Authors
- Shemesh, J., Jalilian, I., Shi, A., Heng Yeoh, G., Knothe Tate, M. L., & Ebrahimi Warkiani, M.
- Affiliations
- UNSW Sydney (AU)
- School of Mechanical and Manufacturing Engineering
- Graduate School of Biomedical Engineering
- ORCID
- Shemesh, Jonathan
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2015
- Volume
- 15
- Issue
- 21
- Pages
- 4114-4127
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1872647657
- Cited by
- 144
- References
- 166
- Citations by year
- 2026: 7 · 2025: 13 · 2024: 11 · 2023: 13 · 2022: 15 · 2021: 17 · 2020: 16 · 2019: 13 · 2018: 10 · 2017: 16 · 2016: 11 · 2015: 2
- FWCI
- 1.30
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Keywords
- flow-induced stress, adherent cells, microfluidics, mechanobiology, shear flow, cell-matrix adhesion, endothelial cell alignment, parallel plate flow chamber
- MeSH terms
- Animals, Cell Adhesion, Humans, Stress, Mechanical, Mechanotransduction, Cellular, Lab-On-A-Chip Devices, Hydrodynamics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.