The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Double rare-earth nanothermometer in aqueous media: opening the third optical transparency window to temperature sensing
Abstract
Owing to the alluring possibility of contactless temperature probing with microscopic spatial resolution, photoluminescence nanothermometry at the nanoscale is rapidly advancing towards its successful application in biomedical sciences. The emergence of near-infrared nanothermometers has paved the way for temperature sensing at the deep tissue level. However, water dispersibility, adequate size at the nanoscale, and the capability to efficiently operate in the second and third biological optical transparency windows are the requirements that still have to be fulfilled in a single nanoprobe. In this work, these requirements are addressed by rare-earth doped nanoparticles with core/shell-architecture, dispersed in water, whose excitation and emission wavelengths conveniently fall within the biological optical transparency windows. Under heating-free 800 nm excitation, double nanothermometry is realized either with Ho3+–Nd3+ (1.18–1.34 μm) or Er3+–Nd3+ (1.55–1.34 μm) NIR emission band ratios, both displaying equal thermal sensitivities around 1.1% °C−1. It is further demonstrated that, along with the interionic energy transfer processes, the thermometric properties of these nanoparticles are also governed by the temperature dependent energy transfer to the surrounding solvent (water) molecules. Overall, this work presents a novel water dispersible double ratiometric nanothermometer operating in the second and third biological optical transparency windows. The temperature dependent particle–solvent interaction is also presented, which is critical for e.g. future in vivo applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical properties of biological tissues: A review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/11/r37 · Cited by 4,008
A clearer vision for in vivo imaging
Weissleder, R. (2001) · Nature Biotechnology · doi:10.1038/86684 · Cited by 3,839
Second window for in vivo imaging
Smith, A. M., Mancini, M. C., & Nie, S. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.326 · Cited by 2,848
Deep optical imaging of tissue using the second and third near-infrared spectral windows
Sordillo, L. A., Pu, Y., Pratavieira, S., Budansky, Y., & Alfano, R. R. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.5.056004 · Cited by 407
Cited by
Rare-Earth Doping in Nanostructured Inorganic Materials
Zheng, B., Fan, J., Chen, B., Qin, X., Wang, J., Wang, F., Deng, R., & Liu, X. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00644 · Cited by 1,204
Lanthanide‐Based Thermometers: At the Cutting‐Edge of Luminescence Thermometry
Brites, C. D. S., Balabhadra, S., & Carlos, L. D. (2019) · Advanced Optical Materials · doi:10.1002/adom.201801239 · Cited by 1,173
Persistent luminescence instead of phosphorescence: History, mechanism, and perspective
Xu, J., & Tanabe, S. (2019) · Journal of Luminescence · doi:10.1016/j.jlumin.2018.09.047 · Cited by 680
Suta, M., & Meijerink, A. (2020) · Advanced Theory and Simulations · doi:10.1002/adts.202000176 · Cited by 306
Metadata
- Authors
- Skripka, A., Benayas, A., Marin, R., Canton, P., Hemmer, E., & Vetrone, F.
- Venue
- Nanoscale
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2017
- Volume
- 9
- Issue
- 9
- Pages
- 3079-3085
- ISSN
- 2040-3364 (ISSN-L)
- 2040-3372
- OpenAlex
- W2584731206
- Cited by
- 178
- References
- 4
- FWCI
- 9.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Double rare-earth nanothermometer in aqueous media: opening the third optical transparency window to temperature sensing. https://app.cochat.ai/papers/10.1039/c6nr08472a
- The paper
- Skripka, A., Benayas, A., Marin, R., Canton, P., Hemmer, E., & Vetrone, F. (2017). Double rare-earth nanothermometer in aqueous media: opening the third optical transparency window to temperature sensing. Nanoscale. https://doi.org/10.1039/c6nr08472a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.