Simultaneous electrical recording of cardiac electrophysiology and contraction on chip
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We report a new heart-on-chip design capable of electrical stimulation, recording of growth, contraction and activating map from in vitro-cultured human cardiac tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Organs-on-chips at the frontiers of drug discovery
Esch, E. W., Bahinski, A., & Huh, D. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4539 · Cited by 1,185
Multi-electrode array technologies for neuroscience and cardiology
Spira, M. E., & Hai, A. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2012.265 · Cited by 991
In vitro cardiac tissue models: Current status and future prospects
Mathur, A., Ma, Z., Loskill, P., Jeeawoody, S., & Healy, K. E. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.09.011 · Cited by 187
Physical developmental cues for the maturation of human pluripotent stem cell-derived cardiomyocytes
Zhu, R., Blazeski, A., Poon, E., Costa, K. D., Tung, L., & Boheler, K. R. (2014) · Stem Cell Research & Therapy · doi:10.1186/scrt507 · Cited by 110
Cited by
Recent Advances in Body-on-a-Chip Systems
Sung, J. H., Wang, Y. I., Narasimhan Sriram, N., Jackson, M., Long, C., Hickman, J. J., & Shuler, M. L. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05293 · Cited by 268
Multi-organ system for the evaluation of efficacy and off-target toxicity of anticancer therapeutics
McAleer, C. W., Long, C. J., Elbrecht, D., Sasserath, T., Bridges, L. R., Rumsey, J. W., Martin, C., Schnepper, M., Wang, Y., Schuler, F., et al. (2019) · Science Translational Medicine · doi:10.1126/scitranslmed.aav1386 · Cited by 199
Drug Toxicity Evaluation Based on Organ-on-a-chip Technology: A Review
Cong, Y., Han, X., Wang, Y., Chen, Z., Lu, Y., Liu, T., Wu, Z., Jin, Y., Luo, Y., & Zhang, X. (2020) · Micromachines · doi:10.3390/mi11040381 · Cited by 140
Flat and microstructured polymeric membranes in organs-on-chips
Pasman, T., Grijpma, D., Stamatialis, D., & Poot, A. (2018) · Journal of The Royal Society Interface · doi:10.1098/rsif.2018.0351 · Cited by 98
Soucy, J. R., Bindas, A. J., Koppes, A. N., & Koppes, R. A. (2019) · iScience · doi:10.1016/j.isci.2019.10.052 · Cited by 62
Liver–heart on chip models for drug safety
Ferrari, E., & Rasponi, M. (2021) · APL Bioengineering · doi:10.1063/5.0048986 · Cited by 53
Sensors-integrated organ-on-a-chip for biomedical applications
Chen, H., Luo, Z., Lin, X., Zhu, Y., & Zhao, Y. (2023) · Nano Research · doi:10.1007/s12274-023-5651-9 · Cited by 47
Metadata
- Authors
- Qian, F., Huang, C., Lin, Y.-D., Ivanovskaya, A. N., O'Hara, T. J., Booth, R. H., Creek, C. J., Enright, H. A., Soscia, D. A., Belle, A. M., Liao, R., Lightstone, F. C., Kulp, K. S., & Wheeler, E. K.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2017
- Volume
- 17
- Issue
- 10
- Pages
- 1732-1739
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2607163305
- Cited by
- 128
- References
- 4
- FWCI
- 4.58
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.