The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
A compartmentalized microfluidic chip with crisscross microgrooves and electrophysiological electrodes for modeling the blood–retinal barrier
Open accessAbstract
This work presents a new microfluidic chip to facilitate multicellular interactions and cell barrier function monitoring in real time.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Particularly for retinal organoids, culture platforms are often designed for research involving the retinal outer segments, and typically do not include RGCs, and employ different cell sources merged in a multilayered system, which does not replicate retinal development.18–23”
From Retinal organoid chip: engineering a physiomimetic oxygen gradient for optimizing long term culture of human retinal organoids (2025) · cites this paper as [21]
Citations
Cites
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
TEER Measurement Techniques for In Vitro Barrier Model Systems
Srinivasan, B., Kolli, A. R., Esch, M. B., Abaci, H. E., Shuler, M. L., & Hickman, J. J. (2015) · SLAS Technology · doi:10.1177/2211068214561025 · Cited by 2,145
Wong, T. Y., Cheung, C. M. G., Larsen, M., Sharma, S., & Simó, R. (2016) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2016.12 · Cited by 1,094
Self-citationWegener, J., Keese, C. R., & Giaever, I. (2000) · Experimental Cell Research · doi:10.1006/excr.2000.4919 · Cited by 769
Characterization of a microfluidic in vitro model of the blood-brain barrier (μBBB)
Booth, R., & Kim, H. (2012) · Lab on a Chip · doi:10.1039/c2lc40094d · Cited by 739
Klaassen, I., Van Noorden, C. J. F., & Schlingemann, R. O. (2013) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2013.02.001 · Cited by 722
Revealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705
Wang, Y. I., Abaci, H. E., & Shuler, M. L. (2017) · Biotechnology and Bioengineering · doi:10.1002/bit.26045 · Cited by 563
Griep, L. M., Wolbers, F., de Wagenaar, B., ter Braak, P. M., Weksler, B. B., Romero, I. A., Couraud, P. O., Vermes, I., van der Meer, A. D., & van den Berg, A. (2013) · Biomedical Microdevices · doi:10.1007/s10544-012-9699-7 · Cited by 537
Henry, O. Y. F., Villenave, R., Cronce, M. J., Leineweber, W. D., Benz, M. A., & Ingber, D. E. (2017) · Lab on a Chip · doi:10.1039/c7lc00155j · Cited by 482
Deli, M. A. (2009) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2008.09.016 · Cited by 385
SyM-BBB: a microfluidic blood brain barrier model
Prabhakarpandian, B., Shen, M.-C., Nichols, J. B., Mills, I. R., Sidoryk-Wegrzynowicz, M., Aschner, M., & Pant, K. (2013) · Lab on a Chip · doi:10.1039/c2lc41208j · Cited by 339
Use of Electric Fields to Monitor the Dynamical Aspect of Cell Behavior in Tissue Culture
Giaever, I., & Keese, C. R. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325896 · Cited by 275
Citi, S. (1992) · The Journal of cell biology · doi:10.1083/jcb.117.1.169 · Cited by 275
Maoz, B. M., Herland, A., Henry, O. Y. F., Leineweber, W. D., Yadid, M., Doyle, J., Mannix, R., Kujala, V. J., FitzGerald, E. A., Parker, K. K., et al. (2017) · Lab on a Chip · doi:10.1039/c7lc00412e · Cited by 266
Measuring direct current trans-epithelial electrical resistance in organ-on-a-chip microsystems
Odijk, M., van der Meer, A. D., Levner, D., Kim, H. J., van der Helm, M. W., Segerink, L. I., Frimat, J.-P., Hamilton, G. A., Ingber, D. E., & van den Berg, A. (2015) · Lab on a Chip · doi:10.1039/c4lc01219d · Cited by 209
Organs-on-a-Chip: A Focus on Compartmentalized Microdevices
Moraes, C., Mehta, G., Lesher-Perez, S. C., & Takayama, S. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0455-6 · Cited by 199
A modular approach to create a neurovascular unit-on-a-chip
Achyuta, A. K. H., Conway, A. J., Crouse, R. B., Bannister, E. C., Lee, R. N., Katnik, C. P., Behensky, A. A., Cuevas, J., & Sundaram, S. S. (2013) · Lab Chip · doi:10.1039/c2lc41033h · Cited by 191
A Novel Dynamic Neonatal Blood-Brain Barrier on a Chip
Deosarkar, S. P., Prabhakarpandian, B., Wang, B., Sheffield, J. B., Krynska, B., & Kiani, M. F. (2015) · PLOS ONE · doi:10.1371/journal.pone.0142725 · Cited by 182
Absorption-Enhancing Mechanism of EDTA, Caprate, and Decanoylcarnitine in Caco-2 Cells
Tomita, M., Hayashi, M., & Awazu, S. (1996) · Journal of Pharmaceutical Sciences · doi:10.1021/js9504604 · Cited by 169
Siliciano, J. D., & Goodenough, D. A. (1988) · The Journal of cell biology · doi:10.1083/jcb.107.6.2389 · Cited by 168
Physiologically relevant organs on chips
Yum, K., Hong, S. G., Healy, K. E., & Lee, L. P. (2013) · Biotechnology Journal · doi:10.1002/biot.201300187 · Cited by 165
Direct quantification of transendothelial electrical resistance in organs-on-chips
van der Helm, M. W., Odijk, M., Frimat, J., van der Meer, A. D., Eijkel, J. C. T., van den Berg, A., & Segerink, L. I. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.06.014 · Cited by 156
Reliable permeability assay system in a microfluidic device mimicking cerebral vasculatures
Yeon, J. H., Na, D., Choi, K., Ryu, S., Choi, C., & Park, J. (2012) · Biomedical Microdevices · doi:10.1007/s10544-012-9680-5 · Cited by 140
Sticker, D., Rothbauer, M., Lechner, S., Hehenberger, M.-T., & Ertl, P. (2015) · Lab on a Chip · doi:10.1039/c5lc01028d · Cited by 137
Haring, A. P., Sontheimer, H. W., & Johnson, B. N. (2017) · Stem Cell Reviews and Reports · doi:10.1007/s12015-017-9738-0 · Cited by 135
Chen, L.-J., Ito, S., Kai, H., Nagamine, K., Nagai, N., Nishizawa, M., Abe, T., & Kaji, H. (2017) · Scientific Reports · doi:10.1038/s41598-017-03788-5 · Cited by 112
Wet‐AMD on a Chip: Modeling Outer Blood‐Retinal Barrier In Vitro
Chung, M., Lee, S., Lee, B. J., Son, K., Jeon, N. L., & Kim, J. H. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700028 · Cited by 105
Workshop meeting report Organs-on-Chips: human disease models
van de Stolpe, A., & den Toonder, J. M. J. (2013) · Lab on a Chip · doi:10.1039/c3lc50248a · Cited by 99
Gardner, T. W., Lesher, T., Khin, S. A., Cuong, V. U., Barber, A. J., & Brennan, W. A. (1996) · Biochemical Journal · doi:10.1042/bj3200717 · Cited by 98
Booth, R., Noh, S., & Kim, H. (2014) · Lab on a Chip · doi:10.1039/c3lc51304a · Cited by 95
Permeability across a novel microfluidic blood-tumor barrier model
Terrell-Hall, T. B., Ammer, A. G., Griffith, J. I. G., & Lockman, P. R. (2017) · Fluids and Barriers of the CNS · doi:10.1186/s12987-017-0050-9 · Cited by 95
Yeste, J., Illa, X., Gutierrez, C., Solé, M., Guimerà‐Brunet, A., & Villa, R. (2016) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/49/37/375401 · Cited by 86
Self-citationInhibition of Protein Kinase C δ Attenuates Blood-Retinal Barrier Breakdown in Diabetic Retinopathy
Kim, J. H., Kim, J. H., Jun, H.-O., Yu, Y. S., & Kim, K.-W. (2010) · American Journal Of Pathology · doi:10.2353/ajpath.2010.090398 · Cited by 80
On-chip epithelial barrier function assays using electrical impedance spectroscopy
Sun, T., Swindle, E. J., Collins, J. E., Holloway, J. A., Davies, D. E., & Morgan, H. (2010) · Lab on a Chip · doi:10.1039/c000699h · Cited by 61
Gabriel, G., Erill, I., Caro, J., Gómez, R., Colom, M. D. R., Villa, R., & Godignon, P. (2007) · Microelectronics Journal · doi:10.1016/j.mejo.2006.11.008 · Cited by 59
Self-citationIncreased Expression of Tight Junctions in ARPE-19 Cells Under Endoplasmic Reticulum Stress
Yoshikawa, T., Ogata, N., Izuta, H., Shimazawa, M., Hara, H., & Takahashi, K. A. (2011) · Current Eye Research · doi:10.3109/02713683.2011.606592 · Cited by 39
miR-15a/16 inhibits TGF-beta3/VEGF signaling and increases retinal endothelial cell barrier proteins
Ye, E., Liu, L., & Steinle, J. J. (2017) · Vision Research · doi:10.1016/j.visres.2017.07.007 · Cited by 38
Biology and Regulation of Blood-Tissue Barriers
Cheng, Y. C. (2014) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4614-4711-5 · Cited by 27
Jiang, Y., Liu, L., & Steinle, J. J. (2017) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.16-20412 · Cited by 25
Oxidative stress regulates expression of claudin-1 in human RPE cells
Hirata, J., Ko, J.-A., Mochizuki, H., Funaishi, K., Yamane, K., Sonoda, K., & Kiuchi, Y. (2014) · Open Life Sciences · doi:10.2478/s11535-014-0287-0 · Cited by 11
Retinal Pigment Epithelium and Macular Diseases
(1998) · Documenta ophthalmologica. Proceedings series · doi:10.1007/978-94-011-5137-5 · Cited by 9
Research works printed but not linked: 3
- Achyuta, 2013, Lab Chip, 13, 542, 10.1039/C2LC41033H · DOI · Paper page
- Huxley, 1987, Am. J. Physiol., 252, H188
- A. Guimerà , G.Gabriel , D.Parramon , E.Calderón and R.Villa , in World Congress on Medical Physics and Biomedical Engineering (Munich, DE, 7–12 September 2009) , ed. O. Dössel , W. C. Schlegel and R. Magjarevic , Springer , Berlin , 2009 , vol. 25/7 , pp. 868–871
Cited by
Azizgolshani, H., Coppeta, J. R., Vedula, E. M., Marr, E. E., Cain, B. P., Luu, R. J., Lech, M. P., Kann, S. H., Mulhern, T. J., Tandon, V., et al. (2021) · Lab on a Chip · doi:10.1039/d1lc00067e · Cited by 225
Fuchs, S., Johansson, S., Tjell, A. Ø., Werr, G., Mayr, T., & Tenje, M. (2021) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.0c01110 · Cited by 213
Advances in Engineering Human Tissue Models
Moysidou, C.-M., Barberio, C., & Owens, R. M. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.620962 · Cited by 179
“The device successfully supported the generation, maintenance and monitoring of a blood-retinal-barrier model, based on the co-culture of primary retinal endothelial cells (HREC), a human neuroblastoma cell line (SH-SY5Y), and a human retinal pigment epithelial cell line (ARPE-19) (Figure 5C), highlighting the necessi…”
BackgroundDevelopmentally inspired human ‘organs on chips’
Ingber, D. E. (2018) · Development · doi:10.1242/dev.156125 · Cited by 124
“…and neuromuscular unit, among others (Kim et al., 2012; Achyuta et al., 2013; Abaci et al., 2015; Benam et al., 2016a; Lee et al., 2016; Musah et al., 2017; Yeste et al., 2017; Wang et al., 2017; Workman et al., 2018; Kasendra et al., 2018; Sances et al., 2018; reviewed by Bhatia and Ingber, 2014).”
Integrating Organs-on-Chips: Multiplexing, Scaling, Vascularization, and Innervation
Park, D., Lee, J., Chung, J. J., Jung, Y., & Kim, S. H. (2020) · Trends in Biotechnology · doi:10.1016/j.tibtech.2019.06.006 · Cited by 105
Metadata
- Authors
- Yeste, J., García-Ramírez, M., Illa, X., Guimerà, A., Hernández, C., Simó, R., & Villa, R.
- Affiliations
- Institut de Microelectrònica de Barcelona, IMB-CNM (CSIC)
- Diabetes and Metabolism Research Unit
- Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (ES)
- Instituto de Salud Carlos III (ES)
- ORCID
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2018
- Volume
- 18
- Issue
- 1
- Pages
- 95-105
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2769549860
- Cited by
- 89
- References
- 43
- Citations by year
- 2026: 6 · 2025: 10 · 2024: 13 · 2023: 11 · 2022: 10 · 2021: 11 · 2020: 13 · 2019: 7 · 2018: 8
- FWCI
- 3.44
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- DIGITAL.CSIC (Spanish National Research Council (CSIC)) (submittedVersion, other-oa)
- Funders
- Ministerio de Economía y Competitividad (SAF2014-62114-EXP, SAF2016-77784-R)
- Fundació la Marató de TV3 (Exp. 201629-10)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Life Sciences › Neuroscience › Neurology › Barrier Structure and Function Studies
- Keywords
- blood-retinal barrier, organ-on-a-chip, transepithelial electrical resistance, paracrine signaling, retinal endothelial cells, SH-SY5Y cells, ARPE-19 cells, barrier permeability, ZO-1 tight junction, co-culture
- MeSH terms
- Cells, Cultured, Equipment Design, Humans, Models, Biological, Retina, Retinal Vessels, Electric Impedance, Cell Culture Techniques, Microfluidic Analytical Techniques, Retinal Pigment Epithelium, Lab-On-A-Chip Devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.