The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
High performance boronic acid-containing hydrogel for biocompatible continuous glucose monitoring
Open accessAbstract
Rapid and robust hydrogels are essential in realizing continuous glucose monitoring in diabetes monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Recently, a low‐power temperature sensor was developed based on complementary temperature dependencies of n‐ and p‐type metal‐oxide‐semiconductor field effect transistors in the subthreshold region.87 Tunneling currents and a capacitive charging‐time‐to‐digital feedback allowed digitizing the temperature at 113 pW, operating from 10 to 60 °C.87”
From Wearables in Medicine (2018) · cites this paper as [87]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Teaching Old Indicators New Tricks
Wiskur, S. L., Ait-Haddou, H., Lavigne, J. J., & Anslyn, E. V. (2001) · Accounts of Chemical Research · doi:10.1021/ar9600796 · Cited by 763
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Kataoka, K., Miyazaki, H., Bunya, M., Okano, T., & Sakurai, Y. (1998) · Journal of the American Chemical Society · doi:10.1021/ja982975d · Cited by 590
Davis, A. P., & Wareham, R. S. (1999) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19991018)38:20<2978::aid-anie2978>3.0.co;2-p · Cited by 489
Boronic acid-containing hydrogels: synthesis and their applications
Guan, Y., & Zhang, Y. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60152h · Cited by 452
Self-citationBoronic Acid-Based Hydrogels Undergo Self-Healing at Neutral and Acidic pH
Deng, C. C., Brooks, W. L. A., Abboud, K. A., & Sumerlin, B. S. (2015) · ACS Macro Letters · doi:10.1021/acsmacrolett.5b00018 · Cited by 438
Biomedical applications of boronic acid polymers
Cambre, J. N., & Sumerlin, B. S. (2011) · Polymer · doi:10.1016/j.polymer.2011.07.057 · Cited by 435
High Ionic Strength Glucose-Sensing Photonic Crystal
Alexeev, V. L., Sharma, A. C., Goponenko, A. V., Das, S., Lednev, I. K., Wilcox, C. S., Finegold, D. N., & Asher, S. A. (2003) · Analytical Chemistry · doi:10.1021/ac030021m · Cited by 405
‘Missing mass’ effect in biosensor's QCM applications
Voinova, M. V., Jonson, M., & Kasemo, B. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00050-7 · Cited by 376
A Glucose‐Selective Molecular Fluorescence Sensor
James, T. D., Sandanayake, K. R. A. S., & Shinkai, S. (1994) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199422071 · Cited by 368
Rodahl, M., Höök, F., & Kasemo, B. (1996) · Analytical Chemistry · doi:10.1021/ac951203m · Cited by 339
Eggert, H., Frederiksen, J., Morin, C., & Norrild, J. C. (1999) · The Journal of Organic Chemistry · doi:10.1021/jo9819279 · Cited by 260
Comparison of the Numerical and Clinical Accuracy of Four Continuous Glucose Monitors
Kovatchev, B., Anderson, S., Heinemann, L., & Clarke, W. (2008) · Diabetes Care · doi:10.2337/dc07-2401 · Cited by 236
Glucose Sensing via Aggregation and the Use of “Knock-Out” Binding To Improve Selectivity
Huang, Y.-J., Ouyang, W.-J., Wu, X., Li, Z., Fossey, J. S., James, T. D., & Jiang, Y.-B. (2013) · Journal of the American Chemical Society · doi:10.1021/ja311442x · Cited by 199
Frequency and dissipation-factor responses to localized liquid deposits on a QCM electrode
Rodahl, M., & Kasemo, B. (1996) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(97)80077-9 · Cited by 188
Su, X.-L., & Li, Y. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.01.021 · Cited by 182
Glucose-Sensitive Holographic Sensors for Monitoring Bacterial Growth
Lee, M.-C., Kabilan, S., Hussain, A., Yang, X., Blyth, J., & Lowe, C. R. (2004) · Analytical Chemistry · doi:10.1021/ac049334n · Cited by 167
Hisamitsu, I., Kataoka, K., Okano, T., & Sakurai, Y. (1997) · Pharmaceutical Research · doi:10.1023/a:1012033718302 · Cited by 160
Bailey, T. S., Zisser, H. C., & Garg, S. K. (2007) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2007.0205 · Cited by 159
Continuous Glucose Sensing with a Fluorescent Thin‐Film Hydrogel
Suri, J. T., Cordes, D. B., Cappuccio, F. E., Wessling, R. A., & Singaram, B. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200352405 · Cited by 149
KAUFMAN, F. R., Austin, J., Neinstein, A. B., Jeng, L., Halvorson, M., Devoe, D. J., & Pitukcheewanont, P. (2002) · The Journal of Pediatrics · doi:10.1067/mpd.2002.129175 · Cited by 143
Rapid detection of Bacillus anthracis using monoclonal antibody functionalized QCM sensor
Hao, R., Wang, D., Zhang, X., et al. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.07.071 · Cited by 139
Wentholt, I. M. E., Vollebregt, M. A., Hart, A. A. M., Hoekstra, J. B. L., & DeVries, J. H. (2005) · Diabetes Care · doi:10.2337/diacare.28.12.2871 · Cited by 130
Gabai, R., Sallacan, N., Chegel, V., Bourenko, T., Katz, E. Y., & Willner, I. (2001) · The Journal of Physical Chemistry B · doi:10.1021/jp0111618 · Cited by 130
Linear and Fast Hydrogel Glucose Sensor Materials Enabled by Volume Resetting Agents
Zhang, C., Cano, G. G., & Braun, P. V. (2014) · Advanced Materials · doi:10.1002/adma.201401710 · Cited by 128
Boronic acids for sensing and other applications - a mini-review of papers published in 2013
Lacina, K., Skládal, P., & James, T. D. (2014) · Chemistry Central Journal · doi:10.1186/s13065-014-0060-5 · Cited by 115
Crosslinking of phenylboronic acid receptors as a means of glucose selective holographic detection
Horgan, A. M., Marshall, A. J., Kew, S. J., Dean, K. E. S., Creasey, C., & Kabilan, S. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.11.028 · Cited by 114
Jin, X., Zhang, X., Wu, Z., Teng, D., Zhang, X., Wang, Y., Wang, Z., & Li, C. (2009) · Biomacromolecules · doi:10.1021/bm8010006 · Cited by 112
Tierney, S., Volden, S., & Stokke, B. T. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.10.014 · Cited by 99
Vejayakumaran, P., Rahman, I. A., Sipaut, C. S., Ismail, J., & Chee, C. K. (2008) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2008.08.054 · Cited by 96
Designed Glucose-Responsive Microgels with Selective Shrinking Behavior
Ancla, C., Lapeyre, V., Gosse, I., Catargi, B., & Ravaine, V. (2011) · Langmuir · doi:10.1021/la202910k · Cited by 89
Wang, H., Zhou, H., Chen, B., Mendes, P. M., Fossey, J., James, T. D., & Long, Y. (2013) · The Analyst · doi:10.1039/c3an01234d · Cited by 78
Selective glucose recognition by boronic acid azoprobe/γ-cyclodextrin complexes in water
Shimpuku, C., Ozawa, R., Sasaki, A., Sato, F., Hashimoto, T., Yamauchi, A., Suzuki, I., & Hayashita, T. (2009) · Chemical Communications · doi:10.1039/b819938h · Cited by 73
Glucose sensing through diffraction grating of hydrogel bearing phenylboronic acid groups
Ye, G., & Wang, X. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.06.029 · Cited by 69
McGarraugh, G. V., & Bergenstal, R. M. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0047 · Cited by 61
Amine effect on phenylboronic acid complex with glucose under physiological pH in aqueous solution
Shno, D., Kubo, A., Murata, Y., Koyama, Y., Kataoka, K., Kikuchi, A., Sakurai, Y., & Okano, T. (1996) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856296x00462 · Cited by 39
Enhancement of sensitivity of glucose sensors from alizarin–boronic acid adducts in aqueous micelles
Ngamdee, K., Noipa, T., Budsombat, S., et al. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.07.023 · Cited by 36
Glucose‐Sensitive QCM‐Sensors Via Direct Surface RAFT Polymerization
Sugnaux, C., & Klok, H. (2014) · Macromolecular Rapid Communications · doi:10.1002/marc.201400217 · Cited by 29
Lazerges, M., Perrot, H., Rabehagasoa, N., et al. (2012) · Biosensors · doi:10.3390/bios2030245 · Cited by 18
Research works printed but not linked: 4
- Ye, 2010, Biosens. Bioelectron., 26, 772, 10.1016/j.bios.2010.06.029 · DOI
- Horgan, 2006, Biosens. Bioelectron., 21, 1838, 10.1016/j.bios.2005.11.028 · DOI
- State Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China , GB/T16886, Standards Press of China, Beijing, 2001
- National Technical Supervision Bureau , GB/T 16175, Standards Press of China, Beijing, 1996
Cited by
Yetisen, A. K., Martinez‐Hurtado, J. L., Ünal, B., Khademhosseini, A., & Butt, H. (2018) · Advanced Materials · doi:10.1002/adma.201706910 · Cited by 569
Self-citation
Metadata
- Authors
- Dou, Q., Hu, D., Gao, H., Zhang, Y., Yetisen, A. K., Butt, H., Wang, J., Nie, G., & Dai, Q.
- Affiliations
- National Center for Nanoscience and Technology (CN)
- Chinese People's Armed Police General Hospital (CN)
- Harvard University (US)
- University of Birmingham (GB)
- Corresponding author
- Nie, Guangjun
- Dai, Qing
- Venue
- RSC Advances
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2017
- Volume
- 7
- Issue
- 66
- Pages
- 41384-41390
- ISSN
- 2046-2069 (ISSN-L)
- OpenAlex
- W2750483221
- Cited by
- 31
- References
- 39
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 4 · 2023: 3 · 2022: 1 · 2021: 7 · 2020: 6 · 2019: 2 · 2018: 5
- FWCI
- 1.37
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- RSC Advances (publishedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion, cc-by)
- Spiral (Imperial College London) (submittedVersion, cc-by)
- Funders
- National Natural Science Foundation of China (2016YFA0201600, 11504063, 51372045)
- Chinese Academy of Sciences (QYZDB‐SSW‐SLH021)
- National Key Research and Development Program of China (2016YFA0201600, 2015CB932400)
- Topics
- Physical Sciences › Materials Science › Biomaterials › Hydrogels: synthesis, properties, applications
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Keywords
- boronic acid, hydrogels, continuous glucose monitoring, diabetes monitoring, biocompatibility, glucose detection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.