Cited by 13Electrolyte and hormonal disordersIon Transport and Channel RegulationDialysis and Renal Disease Management

Metabolic clearance rate of arginine vasopressin in severe chronic renal failure

Argent, Nicholas B., Wilkinson, Robert, Baylis, Peter H.·1992·Clinical Science

Abstract

1. The metabolic clearance rate of arginine vasopressin was determined using a constant infusion technique in normal subjects and patients with chronic renal failure immediately before commencing dialysis. Endogenous arginine vasopressin was suppressed in all subjects before the infusion with a water load. 2. Plasma arginine vasopressin concentrations were determined using a sensitive and specific radioimmunoassay after Florisil extraction. The detection limit of the assay was 0.3 pmol/l, and intra- and inter-assay coefficients of variation at 2 pmol/l were 9.7% and 15.3%, respectively. 3. In normal subjects, the metabolic clearance rate was determined at two infusion rates producing steady-state concentrations of arginine vasopressin of 1.3 and 4.4 pmol/l. In the patients with renal failure, a single infusion rate was used, producing a steady-state concentration of 1.5 pmol/l. 4. At comparable plasma arginine vasopressin concentrations, metabolic clearance rate was significantly reduced in patients with renal failure (normal 1168 ± 235 ml/min versus renal failure 584 ± 169 ml/min; means ± sd; P<0.001). 5. Free water clearance was significantly reduced in normal subjects during the arginine vasopressin infusion from 8.19 ± 2.61 to −1.41 ± 0.51 ml/min (P<0.001), but was unchanged in the patients with renal failure after attaining comparable plasma arginine vasopressin concentrations. 6. In normal subjects there was a small but significant fall in metabolic clearance rate at the higher steady-state arginine vasopressin concentration (1168 ± 235 ml/min at 1.3 pmol/l versus 1059 ± 269 ml/min at 4.4 pmol/l; P = 0.016). 7. Our results show that the metabolic clearance rate of arginine vasopressin is reduced by approximately 50% in severe chronic renal failure. This alone may account for the raised plasma concentrations of the hormone seen in this condition.

Integrity signals

Registry

Crossref · 10.1042/cs0830583

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In patients with chronic renal failure, vasopressin clearance is much slower, with metabolic clearance rate reduced by approximately half, consistent with the conclusion that vasopressin is mainly cleared from the circulation through the kidneys.

    “In patients with chronic renal failure, the clearance is much slower: MCR is reduced by approximately half 108, which is consistent with the conclusion that vasopressin is mainly cleared from the circulation through the kidneys.”

Cited by

Sorted by citations

Authors
Argent, N. B., Wilkinson, R., & Baylis, P. H.
Affiliations
Newcastle University (GB)
Venue
Clinical Science
Published
1992-11-01
Volume
83
Issue
5
Pages
583-587
ISSN
  • 0143-5221 (ISSN-L)
  • 1470-8736
OpenAlex
W2471006465
Cited by
13
References
0
Citations by year
2023: 1 · 2021: 1 · 2019: 2 · 2016: 2
FWCI
0.00
Type
journal article
Language
en
Open access
closed
Locations
  • Clinical Science (publishedVersion)
  • PubMed (publishedVersion)
Funders
Medical Research Council
Topics
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Electrolyte and hormonal disorders
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Ion Transport and Channel Regulation
  • Health Sciences › Medicine › Nephrology › Dialysis and Renal Disease Management
Keywords
vasopressin, metabolic clearance rate, chronic kidney disease, free water clearance, vasopressin infusion, water load, plasma vasopressin concentration, dialysis
MeSH terms
Adolescent, Adult, Arginine Vasopressin, Female, Humans, Kidney, Kidney Failure, Chronic, Male, Metabolic Clearance Rate, Middle Aged, Water

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review