Cited by 23Electrolyte and hormonal disordersDialysis and Renal Disease ManagementCardiovascular, Neuropeptides, and Oxidative Stress Research

Metabolic clearance rate of immunoreactive vasopressin in man

BENMANSOUR, MUSTAPHA, RAINFRAY, MURIEL, PAILLARD, FRANÇOISE, ARDAILLOU, RAYMOND·1982·European Journal of Clinical Investigation

Abstract

Abstract. Metabolic clearance of synthetic arginine vasopressin (AVP) has been measured in sixteen healthy subjects and ten uraemic patients on maintenance haemodialysis. Plasma AVP was measured using a specific radioimmunoassay at different intervals after a single injection of 2 μg AVP. The theoretical curve which fitted best with the disappearance curve was the sum of two exponentials in twenty‐two subjects and of three exponentials in the other four. Metabolic clearance rate and the volume of fast initial distribution were 287·1 ml min‐1 (m 2)‐1 and 219·3 ml/kg b.w., respectively, in normal subjects. Metabolic clearance rate was considerably lower in the uraemic group. This emphasizes the role of kidneys in the degradation of AVP and may account, at least in part, for the higher basal plasma value of this hormone observed in uraemic patients.

Integrity signals

Registry

Crossref · 10.1111/j.1365-2362.1982.tb02228.x

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Later radioimmunoassay studies indicated that vasopressin disappeared from the circulation with a bi-exponential decay: the fast phase had a half-life of 5.4 min and a distribution volume close to the plasma volume, and the slower phase had a half-life of 78 min with a distribution volume close to the extracellular fluid volume.

    “Later studies using radioimmunoassay indicated that vasopressin disappeared from the circulation with a bi‐exponential decay 107. The fast phase had a half‐life of 5.4 min and a distribution volume close to the plasma volume; the slower phase had a half‐life of 78 min with a distribution volume close to the extracellular fluid volume.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
BENMANSOUR, M., RAINFRAY, M., PAILLARD, F., & ARDAILLOU, R.
Affiliations
Inserm (FR)
Corresponding author
ARDAILLOU, RAYMOND
Venue
European Journal of Clinical Investigation
Publisher
Wiley
Published
1982-12
Volume
12
Issue
6
Pages
475-480
ISSN
  • 0014-2972 (ISSN-L)
  • 1365-2362
OpenAlex
W2121365479
Cited by
23
References
18
Citations by year
2024: 1 · 2020: 1 · 2017: 1 · 2016: 2
FWCI
1.24
Type
journal article
Language
en
Open access
closed
Locations
  • European Journal of Clinical Investigation (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Electrolyte and hormonal disorders
  • Health Sciences › Medicine › Nephrology › Dialysis and Renal Disease Management
  • Health Sciences › Medicine › Surgery › Cardiovascular, Neuropeptides, and Oxidative Stress Research
Keywords
vasopressin, metabolic clearance rate, uremia, hemodialysis, plasma vasopressin, volume of distribution, renal function
MeSH terms
Adult, Arginine Vasopressin, Blood Pressure, Creatinine, Female, Renal Dialysis, Humans, Kidney, Kidney Failure, Chronic, Male, Metabolic Clearance Rate, Middle Aged, Radioimmunoassay

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review