CoChat

Comparison of Bio-Impedance Spectroscopy and Multi-Frequency Bio-Impedance Analysis for the Assessment of Extracellular and Total Body Water in Surgical Patients

Hannan, W. J., Cowen, S. J., Plester, C. E., Fearon, K. C. H., Debeau, A. · 1995 · Clinical Science
Cited by 119

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

1. Measurements of extracellular and total body water provide useful information on the nutritional status of surgical patients and may be estimated from whole-body bio-impedance measurements at different frequencies. 2. Resistance and reactance were measured at 50 frequencies from 5 kHz to 1 MHz in 29 surgical patients (17 males, 12 females) with a wide range of extracellular to total body water ratios. 3. A fit to the spectrum of reactance versus resistance data gave predicted resistances at frequencies zero and infinity. Values of extracellular and total body water determined by this bio-impedance spectroscopy technique were regressed against values obtained from radioisotope dilution. The standard errors of the estimate were 1.893l and 3.259l respectively. 4. Resistance indices (height2/resistance) at selected frequencies gave the highest correlations with extracellular and total body water at 5 kHz and 200 kHz respectively, and prediction equations derived from multiple stepwise regressions also showed these to be the optimum frequencies. The standard errors of the estimate for this multi-frequency bio-impedance analysis method were 1.937l and 2.606l for extracellular and total body water respectively. 5. To assess the ability of the two methods to measure changes in extracellular and total body water, reproducibility was assessed from repeat measurements 10 min apart in a subgroup of 15 patients. Bio-impedance spectroscopy gave mean coefficients of variation for extracellular and total body water of 0.9% and 3.0% respectively. For multi-frequency bio-impedance analysis the corresponding coefficients of variation were 0.9% and 0.6%. 6. It is concluded that a simple impedance analyser operating at only two frequencies compares favourably with the more complex spectroscopy technique for the determination of extracellular and total body water in surgical patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1042/cs0890651

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 119

Metadata

Authors
Hannan, W. J., Cowen, S. J., Plester, C. E., Fearon, K. C. H., & Debeau, A.
Venue
Clinical Science
Published
1995-12-01
Volume
89
Issue
6
Pages
651-658
ISSN
  • 0143-5221 (ISSN-L)
  • 1470-8736
OpenAlex
W2255122027
Cited by
119
References
1
FWCI
2.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.