CoChat

Autonomic Control of Skin Microvessels: Assessment by Power Spectrum of Photoplethysmographic Waves

Bernardi, Luciano, Radaelli, Alberto, Solda, Pier Luigi, Coats, Andrew J. S., Reeder, Martin, Calciati, Alessandro, Garrard, Christopher S., Sleight, Peter · 1996 · Clinical Science
Cited by 147

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

1. Although it is well known that the microvessels of the skin constantly undergo spontaneous variations in volume, the significance of these rhythmic changes remains uncertain. 2. In 10 healthy males and in 15 patients in intensive care, we assessed the origin of the autonomic influences on spontaneous fluctuations in the microcirculation of the skin, obtained by an infra-red photoplethysmographic device; we used spectral analysis techniques to compare these fluctuations (which were recorded simultaneously in two sites) with those of blood pressure, in order to test the presence of autonomic control of any synchronous fluctuations in these different measurements from the cardiovascular system. In order to minimize mechanical fluctuations caused by occasional slow breaths, rather than nervously mediated fluctuations in skin blood flow, respiration was controlled at 15 breaths/min (0.25 Hz). 3. Spontaneous infra-red photoplethysmographic fluctuations were observed in different body areas (left index finger and left ear lobe, right and left index finger), and all were evident at 0.1 Hz, as well as respiration-related components at 0.25 Hz. Active standing increased the power of the 0.1 Hz fluctuations (sympathetic activity) in both blood pressure (from 62.7 ± 7.1 to 79.2 ± 3.7 normalized units, P<0.05) and IRP (finger: from 68.5 ± 6.4 to 86.9 ± 3.4 normalized units, P<0.05; ear: from 59.0 ± 5.9 to 88.1 ± 2.0, P<0.01). There was a high (>0.5) coherence between the fluctuations obtained in blood pressure, in IRP signals obtained simultaneously at the finger and at the ear, and in R—R interval. This synchronization between the oscillations in all these signals, which were unrelated to the respiratory frequency or to the pulse rate, suggests a common neural, non-local origin. The phase between IRP and blood pressure was positive in the 0.1 Hz region (+ 1.65 ± 0.41 radians, i.e. IRP was leading blood pressure, showing that 0.1 Hz fluctuations were not passively transmitted to the skin microvessels from large arteries) and negative in the 0.25 Hz region (−0.74 ± 0.19 radians, P<0.01 compared with phase in the 0.1 Hz region, i.e. IRP was lagging behind blood pressure, suggesting possible passive transmission to the skin microvessels of blood pressure fluctuations caused by respiration). Fluctuations at lower frequency were observed in all IRP recordings, suggesting a local origin for these. Intra-arterial and IRP fluctuations were compared in the 15 intensive care patients and gave similar results. 4. The skin microcirculation is thus not only under local control, but also reflects changes in sympathetic activity; the effect of these changes on the skin microcirculation can be easily evaluated by the spectral analysis of the IRP signal obtained simultaneously in multiple areas, in conjunction with the spectra of R—R interval and blood pressure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1042/cs0900345

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 147

Metadata

Authors
Bernardi, L., Radaelli, A., Solda, P. L., Coats, A. J. S., Reeder, M., Calciati, A., Garrard, C. S., & Sleight, P.
Venue
Clinical Science
Published
1996-05-01
Volume
90
Issue
5
Pages
345-355
ISSN
  • 0143-5221 (ISSN-L)
  • 1470-8736
OpenAlex
W2224301793
Cited by
147
References
5
FWCI
2.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.