CoChat

Adipose tissue thickness affects in vivo quantitative near-IR spectroscopy in human skeletal muscle

VAN BEEKVELT, M. C. P., BORGHUIS, M. S., VAN ENGELEN, B. G. M., WEVERS, R. A., COLIER, W. N. J. M. · 2001 · Clinical Science

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

The influence of adipose tissue thickness (ATT) on near-IR spectroscopy (NIRS) measurements in vivo was studied in the human flexor digitorum superficialis muscle at rest and during sustained isometric handgrip exercise. NIRS was used for the quantitative measurement of muscle O(2) consumption (mV.O(2)) and forearm blood flow (FBF) in 78 healthy subjects. Skinfold thickness ranged from 1.4 to 8.9 mm within the group. Resting mV.O(2) was 0.11+/-0.04 ml of O(2).min(-1).100 g(-1), and FBF was 1.28+/-0.82 ml.min(-1).100 ml(-1). There was a negative correlation (r=-0.70, P< or =0.01), indicating a decrease in mV.O(2) with increasing ATT. mV.O(2) in the 10 leanest subjects appeared to be twice as high as that in the 10 subjects with the highest ATT. A poor correlation (r=0.29, P< or =0.01) was found between ATT and FBF. The gender difference that we found for mV.O(2) was due to the difference in ATT between female and male subjects. No correlation was found between maximum voluntary contraction and mV.O(2), nor between maximum voluntary contraction and ATT, indicating that the contraction force did not confound our results. These results show that ATT has a substantial confounding influence on in vivo NIRS measurements, and that it is essential to incorporate this factor into future NIRS muscle studies in order to justify comparisons between different groups. To facilitate such comparisons, upper and lower boundaries for normal values of mV.O(2) and FBF in relation to ATT are prese…

Overview

Integrity signals

Registry

Crossref · 10.1042/cs1010021

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 20 references

Cited by

See all 424

Metadata

Authors
VAN BEEKVELT, M. C. P., BORGHUIS, M. S., VAN ENGELEN, B. G. M., WEVERS, R. A., & COLIER, W. N. J. M.
Affiliations
  • Neuromuscular Centre Nijmegen, Institute of Neurology, University Medical Centre Nijmegen, P.O. Box 9101, 6500 HB Nijmegen, The Netherlands
  • Radboud University Medical Center (NL)
Venue
Clinical Science
Published
2001-05-29
Volume
101
Issue
1
Pages
21-28
ISSN
  • 0143-5221 (ISSN-L)
  • 1470-8736
OpenAlex
W2005647586
Cited by
369
References
20
Citations by year
2026: 12 · 2025: 9 · 2024: 17 · 2023: 11 · 2022: 16 · 2021: 18 · 2020: 23 · 2019: 15 · 2018: 19 · 2017: 21 · 2016: 16 · 2015: 14 · 2014: 14 · 2013: 19 · 2012: 23
FWCI
4.43
Type
journal article
Language
en
Open access
closed
Locations
  • Clinical Science (publishedVersion)
  • PubMed (publishedVersion)
  • Radboud Repository (Radboud University) (submittedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
Keywords
adipose tissue thickness, near-infrared spectroscopy, muscle oxygen consumption, forearm blood flow, flexor digitorum superficialis, isometric handgrip exercise, skinfold thickness, sex differences, maximal voluntary contraction, muscle oxygenation
MeSH terms
Adipose Tissue, Adult, Female, Humans, Male, Oxygen Consumption, Regional Blood Flow, Sex Factors, Skinfold Thickness, Reproducibility of Results, Exercise, Normal Distribution, Muscle, Skeletal, Spectroscopy, Near-Infrared

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.