CoChat

Neuromuscular electrical stimulation prevents muscle wasting in critically ill comatose patients

Open access
Dirks, Marlou L., Hansen, Dominique, Van Assche, Aimé, Dendale, Paul, Van Loon, Luc J. C. · 2015 · Clinical Science
Cited by 157

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

Fully sedated patients, being treated in the intensive care unit (ICU), experience substantial skeletal muscle loss. Consequently, survival rate is reduced and full recovery after awakening is compromised. Neuromuscular electrical stimulation (NMES) represents an effective method to stimulate muscle protein synthesis and alleviate muscle disuse atrophy in healthy subjects. We investigated the efficacy of twice-daily NMES to alleviate muscle loss in six fully sedated ICU patients admitted for acute critical illness [n=3 males, n=3 females; age 63±6 y; APACHE II (Acute Physiology and Chronic Health Evaluation II) disease-severity-score: 29±2]. One leg was subjected to twice-daily NMES of the quadriceps muscle for a period of 7±1 day whereas the other leg acted as a non-stimulated control (CON). Directly before the first and on the morning after the final NMES session, quadriceps muscle biopsies were collected from both legs to assess muscle fibre-type-specific cross-sectional area (CSA). Furthermore, phosphorylation status of the key proteins involved in the regulation of muscle protein synthesis was assessed and mRNA expression of selected genes was measured. In the CON leg, type 1 and type 2 muscle–fibre-CSA decreased by 16±9% and 24±7% respectively (P<0.05). No muscle atrophy was observed in the stimulated leg. NMES increased mammalian target of rapamycin (mTOR) phosphorylation by 19±5% when compared with baseline (P<0.05), with no changes in the CON leg. Furthermore, mRNA expression of key genes involved in muscle protein breakdown either declined [forkhead box protein O1 (FOXO1); P<0.05] or remained unchanged [muscle atrophy F-box (MAFBx) and muscle RING-finger protein-1 (MuRF1)], with no differences between the legs. In conclusion, NMES represents an effective and feasible interventional strategy to prevent skeletal muscle atrophy in critically ill comatose patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1042/cs20140447

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 157

Metadata

Authors
Dirks, M. L., Hansen, D., Van Assche, A., Dendale, P., & Van Loon, L. J. C.
Venue
Clinical Science
Published
2014-11-28
Volume
128
Issue
6
Pages
357-365
ISSN
  • 0143-5221 (ISSN-L)
  • 1470-8736
OpenAlex
W2023500696
Cited by
157
References
15
FWCI
4.26
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Neuromuscular electrical stimulation prevents muscle wasting in critically ill comatose patients. https://app.cochat.ai/papers/10.1042/cs20140447
The paper
Dirks, M. L., Hansen, D., Van Assche, A., Dendale, P., & Van Loon, L. J. C. (2015). Neuromuscular electrical stimulation prevents muscle wasting in critically ill comatose patients. Clinical Science. https://doi.org/10.1042/cs20140447

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.