CoChat

The Effects of Directional Processing on Objective and Subjective Listening Effort

Picou, Erin M., Moore, Travis M., Ricketts, Todd A. · 2017 · Journal of Speech, Language, and Hearing Research
Cited by 37

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

Purpose: The purposes of this investigation were (a) to evaluate the effects of hearing aid directional processing on subjective and objective listening effort and (b) to investigate the potential relationships between subjective and objective measures of effort. Method: Sixteen adults with mild to severe hearing loss were tested with study hearing aids programmed with 3 settings: omnidirectional, fixed directional, and bilateral beamformer. A dual-task paradigm and subjective ratings were used to assess objective and subjective listening effort, respectively, in 2 signal-to-noise ratios. Testing occurred in rooms with either low or moderate reverberation. Results: Directional processing improved subjective and objective listening effort, although benefit for objective effort was found only in moderate reverberation. Subjective reports of work and tiredness were more highly correlated with word recognition performance than objective listening effort. However, subjective ratings about control were significantly correlated with objective listening effort. Conclusions: Directional microphone technology in hearing aids has the potential to improve listening effort in moderately reverberant environments. In addition, subjective questions that probe a listener's desire to exercise control may be a viable method for eliciting ratings that are significantly related to objective listening effort.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1044/2016_jslhr-h-15-0416

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 64

  1. American National Standards Institute, 1996, Specifications for audiometers (ANSI S.36-1996)
  2. 10.3109/14992027.2015.1059502 · DOI
  3. 10.1097/AUD.0b013e318174f067 · DOI
  4. Brons I. Houben R. & Dreschler W. A. (2014). Effects of noise reduction on speech intelligibility perceived listening effort and personal preference in hearing-impaired listeners. Trends in Hearing 18. doi:10.1177/2331216514553924 · DOI
  5. 10.1109/TASL.2010.2090519 · doi:10.1109/tasl.2010.2090519
  6. 10.1097/00003446-198710001-00010 · doi:10.1097/00003446-198710001-00010
  7. 10.1097/00003446-198808000-00005 · doi:10.1097/00003446-198808000-00005
  8. 10.1016/S0022-5371(72)80001-X · DOI · Paper page
  9. Davis H., 1960, Hearing and deafness
  10. 10.1044/jshr.2904.535 · DOI
  11. 10.1097/AUD.0000000000000028 · DOI · Paper page
  12. 10.1044/jshd.4702.114 · doi:10.1044/jshd.4702.114
  13. 10.1044/jshr.2104.702 · DOI
  14. 10.1121/1.384767 · DOI
  15. 10.1037/0278-7393.5.5.472 · DOI
  16. 10.1121/1.393534 · DOI
  17. 10.1097/00003446-199204000-00003 · DOI
  18. 10.1044/jshr.2103.440 · DOI · Paper page
  19. 10.1044/1092-4388(2009/08-0140) · doi:10.1044/1092-4388(2009/08-0140
  20. 10.3109/03005369009077843 · DOI · Paper page
  21. 10.1044/1092-4388(2010/10-0069) · doi:10.1044/1092-4388(2010/10-0069
  22. 10.3109/03005369509086600 · DOI
  23. 10.3109/03005369109079853 · DOI · Paper page
  24. 10.1080/14992020500190011 · DOI · Paper page
  25. 10.3109/00206098509078350 · doi:10.3109/00206098509078350
  26. 10.1044/jshd.4903.278 · DOI · Paper page
  27. 10.1044/1092-4388(2002/046) · doi:10.1044/1092-4388(2002/046 · Paper page
  28. 10.1044/jshr.3304.726 · DOI · Paper page
  29. International Standards Organization, 2009, Acoustics—Measurement of room acoustic parameters—Part 1: Performance spaces (ISO 3382-1: 2009)
  30. 10.1044/2015_AJA-14-0058 · DOI
  31. Kahneman D., 1973, Attention and effort
  32. 10.1177/1084713812468511 · doi:10.1177/1084713812468511
  33. 10.1097/01.HJ.0000285745.08599.7f · DOI · Paper page
  34. Lotter T., 2006, Dual-channel speech enhancement by superdirective beamforming, EURASIP Journal on Applied Signal Processing, 2006
  35. Madison T., 1983, The signal-to-noise ratio advantage of directional microphones, Hearing Instruments, 34, 18
  36. 10.3109/14992027.2013.769066 · DOI · Paper page
  37. 10.1044/jshr.2403.375 · doi:10.1044/jshr.2403.375
  38. 10.1044/jshr.1704.724 · DOI
  39. Nunnally J. C., 1994, Psychometric theory
  40. 10.1044/1092-4388(2012/12-0074) · doi:10.1044/1092-4388(2012/12-0074
  41. 10.1121/1.421128 · DOI · Paper page
  42. Peterson P. M., 1987, Multimicrophone adaptive beamforming for interference reduction in hearing aids, Journal of Rehabilitation Research and Development, 24, 103
  43. 10.1097/AUD.0000000000000004 · DOI
  44. 10.1097/AUD.0000000000000222 · DOI
  45. 10.1097/AUD.0000000000000055 · DOI
  46. 10.3109/14992027.2014.880814 · DOI
  47. 10.1044/1092-4388(2011/10-0154) · doi:10.1044/1092-4388(2011/10-0154 · Paper page
  48. 10.1097/AUD.0b013e31827f0431 · DOI
  49. 10.1121/1.381753 · DOI · Paper page
  50. 10.1044/jshr.2902.146 · DOI
  51. Preves D. A., 1999, Field trial evaluations of a switched directional/omnidirectional in-the-ear hearing instrument, Journal of the American Academy of Audiology, 10, 273, 10.1055/s-0042-1748498 · doi:10.1055/s-0042-1748498
  52. 10.1121/1.4897398 · DOI · Paper page
  53. 10.1097/00003446-200006000-00002 · doi:10.1097/00003446-200006000-00002
  54. Ricketts T. A., 2002, Hearing aids: Standards, options and limitations, 274
  55. 10.1097/01.AUD.0000100202.00312.02 · doi:10.1097/01.aud.0000100202.00312.02
  56. 10.1080/14992020500258602 · DOI
  57. 10.1080/14992020802304393 · DOI
  58. 10.1121/1.2839283 · DOI · Paper page
  59. Sriram S., 2008, Beamforming under quantization errors in wireless binaural hearing aids, EURASIP Journal on Audio, Speech, and Music Processing, 2008
  60. 10.1044/jshr.2803.455 · DOI · Paper page
  61. 10.3766/jaaa.18.4.6 · DOI
  62. 10.1037/a0014802 · DOI · Paper page
  63. 10.3766/jaaa.21.2.3 · DOI
  64. 10.1097/AUD.0000000000000079 · DOI

Cited by

See all 37

Metadata

Authors
Picou, E. M., Moore, T. M., & Ricketts, T. A.
Affiliations
Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN
Venue
Journal of Speech, Language, and Hearing Research
Published
2017-01
Volume
60
Issue
1
Pages
199-211
ISSN
  • 1092-4388
  • 1558-9102
Cited by
37
References
12
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.