Evaluation of an improved scoring system for the grading of direct laryngoscopy
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A modified version of the Cormack and Lehane scoring system was prospectively evaluated in 663 patients requiring tracheal intubation. In the modified system, grade 2 (only part of the glottis visible) was divided into 2a (part of the cords visible) and 2b (only the arytenoids or the very posterior origin of the cords visible). One hundred and sixty‐two intubations (24.4%) were scored as grade 2a and 43 (6.5%) as grade 2b, of which seven (4.3%) and 29 (67.4%), respectively, were difficult, defined as requiring more than one laryngoscopy or the use of specialist equipment. Grade 2b denotes a laryngoscopic view that is relatively common and is often associated with difficulty passing a tracheal tube. The modified scoring system thus provides more information than the original Cormack and Lehane system and its use should be considered when recording the ease of tracheal intubation in the anaesthetic record or in studies of tracheal intubation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Difficult tracheal intubation in obstetrics
CORMACK, R. S., & LEHANE, J. (1984) · Anaesthesia · doi:10.1111/j.1365-2044.1984.tb08932.x · Cited by 2,471
PREDICTING DIFFICULT INTUBATION
WILSON, M. E., SPIEGELHALTER, D., ROBERTSON, J. A., & LESSER, P. (1988) · British Journal of Anaesthesia · doi:10.1093/bja/61.2.211 · Cited by 875
Adnet, F., Borron, S. W., Racine, S. X., Clemessy, J.-L., Fournier, J.-L., Plaisance, P., & Lapandry, C. (1997) · Anesthesiology · doi:10.1097/00000542-199712000-00005 · Cited by 703
The incidence of airway problems depends on the definition used
Rose, D., & Cohen, M. M. (1996) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03015954 · Cited by 152
The effect of cricoid pressure and neck support on the view at laryngoscopy
Vanner, R. G., Clarke, P. Y., Moore, W. J., & Raftery, S. (1997) · Anaesthesia · doi:10.1111/j.1365-2044.1997.181-az0315.x · Cited by 116
Grading of direct laryngoscopy A survey of current practice
Cohen, A. M., Fleming, B., & Wace, J. R. (1994) · Anaesthesia · doi:10.1111/j.1365-2044.1994.tb03526.x · Cited by 38
Cited by
Frerk, C., Mitchell, V. S., McNarry, A. F., Mendonca, C., Bhagrath, R., Patel, A., O’Sullivan, E. P., Woodall, N. M., & Ahmad, I. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev371 · Cited by 2,214
Complications and failure of airway management
Cook, T. M., & MacDougall-Davis, S. R. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes393 · Cited by 525
for the Canadian Airway Focus Group, Law, J. A., Broemling, N., Cooper, R. M., Drolet, P., Duggan, L. V., Griesdale, D. E., Hung, O. R., Jones, P. M., Kovacs, G., et al. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0019-3 · Cited by 358
“Difficult laryngoscopy: Laryngeal exposure using DL is generally quantified using the Cormack-Lehane grade(19) or one of its modifications.(20,21) Most authorities agree that grade 1 and 2 views, where most or some portion of the glottis is seen, represent easy DL, while grade 3 and 4 views represent difficult and fai…”
MethodAziz, M. F., Dillman, D., Fu, R., & Brambrink, A. M. (2012) · Anesthesiology · doi:10.1097/aln.0b013e318246ea34 · Cited by 352
Khan, Z. H., Kashfi, A., & Ebrahimkhani, E. (2003) · Anesthesia & Analgesia · doi:10.1097/00000539-200302000-00053 · Cited by 323
Metadata
- Authors
- Yentis, S. M., & Lee, D. J. H.
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 1998-11
- Volume
- 53
- Issue
- 11
- Pages
- 1041-1044
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W2159751686
- Cited by
- 369
- References
- 6
- FWCI
- 4.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.