The intubating laryngeal maskResults of a multicentre trial with experience of 500 cases
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
A multicentre trial of the use of the intubating laryngeal mask was carried out at seven centres in the United Kingdom using the same agreed protocol. Lung ventilation followed by blind tracheal intubation through the intubating laryngeal mask was attempted on 500 ASA grade 1 and 2 patients. It was possible to insert the intubating laryngeal mask in all 500 cases. Ventilation via the intubating laryngeal mask was described as satisfactory in 475 (95%) cases, difficult in 20 (4%) cases and unsatisfactory in 5 (1%) cases. Blind tracheal intubation through the intubating laryngeal mask was possible in 481 (96.2%) cases within three attempts. Intubation was successful at the first attempt in 399 (79.8%) cases, at the second attempt in 62 (12.4%) cases and at the third attempt in 20 (4%) cases. The tracheas of 19 (3.8%) patients were not successfully intubated within the three attempts. Ventilation via the intubating laryngeal mask was described as unsatisfactory during two of these cases but oxygenation remained satisfactory in spite of this. Seventeen of the 19 failures occurred during the individual operator's first 20 attempts. The intubating laryngeal mask provides a successful method for blind tracheal intubation in a large proportion of cases and appears to be superior to the standard laryngeal mask airway for this purpose. The intubating laryngeal mask may be of use when tracheal intubation has failed using conventional methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Difficult tracheal intubation: a retrospective study
SAMSOON, G. L. T., & YOUNG, J. R. B. (1987) · Anaesthesia · doi:10.1111/j.1365-2044.1987.tb04039.x · Cited by 1,584
Adverse Respiratory Events in Anesthesia: A Closed Claims Analysis
Caplan, R. A., Posner, K. L., Ward, R. J., & Cheney, F. W. (1990) · Anesthesiology · doi:10.1097/00000542-199005000-00010 · Cited by 1,060
The airway: problems and predictions in 18,500 patients
Rose, D. K., & Cohen, M. M. (1994) · Canadian Journal of Anaesthesia · doi:10.1007/bf03009858 · Cited by 645
Brain, A. I., Verghese, C., Addy, E. V., Kapila, A., & Brimacombe, J. (1997) · British Journal of Anaesthesia · doi:10.1093/bja/79.6.704 · Cited by 323
Predicting difficult intubation
Frerk, C. (1991) · Anaesthesia · doi:10.1111/j.1365-2044.1991.tb09909.x · Cited by 299
The intubating laryngeal mask. I: Development of a new device for intubation of the trachea
Brain, A. I. J., Verghese, C., Addy, E. V., & Kapila, A. (1997) · British Journal of Anaesthesia · doi:10.1093/bja/79.6.699 · Cited by 267
The intubating laryngeal mask airway: an initial assessment of performance
Kapila, A., Addy, E. V., Verghese, C., & Brain, A. I. J. (1997) · British Journal of Anaesthesia · doi:10.1093/bja/79.6.710 · Cited by 180
Difficult direct laryngoscopy in patients with cervical spine disease
CALDER, I., CALDER, J., & CROCKARD, H. A. (1995) · Anaesthesia · doi:10.1111/j.1365-2044.1995.tb06135.x · Cited by 170
Analysis of 1500 laryngeal mask uses by one anaesthetist in adults undergoing routine anaesthesia
Brimacombe, J. (1996) · Anaesthesia · doi:10.1111/j.1365-2044.1996.tb07660.x · Cited by 166
The intubating laryngeal mask: Use in failed and difficult intubation
Parr, M. J., Gregory, M., & Baskett, P. J. F. (1998) · Anaesthesia · doi:10.1046/j.1365-2044.1998.00319.x · Cited by 153
Self-citationPredicting difficult intubation
Frerk, C. M. (1992) · Anaesthesia · doi:10.1111/j.1365-2044.1992.tb02282.x · Cited by 32
A system for psychomotor evaluation; design, implementation and practice effects in volunteers
Hope, A., Woolman, P. S., Gray, W. M., Asbury, A. J., & Millar, K. (1998) · Anaesthesia · doi:10.1046/j.1365-2044.1998.00434.x · Cited by 23
Stress response in orthopaedics and trauma in paediatrics: general versus regional anaesthesia
WOLF, A. R. (1998) · Anaesthesia · doi:10.1111/j.1365-2044.1998.tb15167.x · Cited by 12
Cited by
Deakin, C. D., Nolan, J. P., Soar, J., Sunde, K., Koster, R. W., Smith, G. B., & Perkins, G. D. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.08.017 · Cited by 2,700
Self-citationDifficult Airway Society guidelines for management of the unanticipated difficult intubation
Henderson, J. J., Popat, M. T., Latto, I. P., & Pearce, A. C. (2004) · Anaesthesia · doi:10.1111/j.1365-2044.2004.03831.x · Cited by 1,025
European Resuscitation Council Guidelines for Resuscitation 2005
Nolan, J. P., Deakin, C. D., Soar, J., Böttiger, B. W., & Smith, G. (2005) · Resuscitation · doi:10.1016/j.resuscitation.2005.10.009 · Cited by 834
Self-citationEuropean Resuscitation Council Guidelines for Resuscitation 2005
Soar, J., Deakin, C. D., Nolan, J. P., Abbas, G., Alfonzo, A., Handley, A. J., Lockey, D., Perkins, G. D., & Thies, K. (2005) · Resuscitation · doi:10.1016/j.resuscitation.2005.10.004 · Cited by 832
Self-citationfor the Canadian Airway Focus Group, Law, J. A., Broemling, N., Cooper, R. M., Drolet, P., Duggan, L. V., Griesdale, D. E., Hung, O. R., Jones, P. M., Kovacs, G., et al. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0019-3 · Cited by 358
Metadata
- Authors
- Baskett, P. J. F., Parr, M. J. A., & Nolan, J. P.
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 1998-12
- Volume
- 53
- Issue
- 12
- Pages
- 1174-1179
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W1608266421
- Cited by
- 224
- References
- 13
- FWCI
- 17.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.