CoChat

Methodological aspects of the evaluation of endothelium‐dependent vasodilatation in the human forearm

Lind, Sarabi, Millgård · 1998 · Clinical Physiology
Cited by 110

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The present study, involving 56 healthy subjects from a health screening, was undertaken to address some methodological questions regarding the measurement of endothelial function using local intra‐arterial infusions of metacholine (2 and 5 μg min−1) to evaluate endothelium‐dependent vasodilatation, and sodium nitroprusside (SNP, 5 and 10 μg min−1) to evaluate endothelium‐independent vasodilatation. Forearm blood flow (FBF) was measured by venous occlusion plethysmography. The ratio of FBF during the highest dose of metacholine to FBF during the highest dose of SNP was used as an index of endothelial function. In 10 young volunteers the procedure was repeated after 2 h and again after 3 weeks in order to study short‐term and long‐term reproducibility of the method. Neither the vasodilatatory response to metacholine (r = 0·006) nor that to SNP (r = 0·08) was related to resting FBF. Neither the circumference nor the length of the arm was related to endothelial function (r = 0·01−0·11), as evaluated by the FBF on metacholine to nitroprusside ratio (mean 1·3 ± 0·3 SD). The use of a wrist cuff to exclude hand circulation, or not, did not influence the evaluation of endothelial function significantly. Maximal FBF after 3 min of arterial occlusion of the forearm was significantly related to blood flow during both metacholine (r = 0·53, P < 0·01) and nitroprusside infusion (r = 0·36, P < 0·05), but not to the FBF on metacholine to nitroprusside ratio (r = 0·01). The short‐term and long‐term reproducibility of FBF during vasodilatation with metacholine and SNP was good (r = 0·89−0·97, P < 0·001), while the individual measurements for resting FBF were less reproducible when repeated after 3 weeks (r = 0·34). In conclusion, endothelial function was not related to resting FBF, nor to the arm circumference or length. No major difference was seen whether endothelial function was evaluated with or without exclusion of the hand circulation. Maximal FBF during reactive hyperaemia was not related to endothelial function.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1365-2281.1998.00077.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 110

Metadata

Authors
Lind, Sarabi, & Millgård
Venue
Clinical Physiology
Publisher
Wiley
Published
1998-03
Volume
18
Issue
2
Pages
81-87
ISSN
  • 0144-5979 (ISSN-L)
  • 1365-2281
OpenAlex
W2072144565
Cited by
110
References
3
FWCI
6.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Methodological aspects of the evaluation of endothelium‐dependent vasodilatation in the human forearm. https://app.cochat.ai/papers/10.1046/j.1365-2281.1998.00077.x
The paper
Lind, Sarabi, & Millgård. (1998). Methodological aspects of the evaluation of endothelium‐dependent vasodilatation in the human forearm. Clinical Physiology. https://doi.org/10.1046/j.1365-2281.1998.00077.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.