Ultrasound decontamination of minimally processed fruits and vegetables
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
The effectiveness of power ultrasound for the microbial decontamination of minimally processed fruits and vegetables was studied. Reductions in Salmonella typhimurium attached to iceberg lettuce obtained by cleaning with water, chlorinated water, ultrasound with water and ultrasound with chlorinated water were 0.7, 1.7, 1.5 and 2.7 logs, respectively, for small-scale (2 L) trials. The cleaning action of cavitation appears to remove cells attached to the surface of fresh produce, rendering the pathogens more susceptible to the sanitizer. For large-scale (40 L) trials, the addition of chlorine to water in the tank gave a systematic difference in Escherichia coli decontamination efficiency. However, the frequency of ultrasound treatment (25, 32–40, 62–70 kHz) had no significant effect on decontamination efficiency (P > 0.69). With the potentially high capital expenditure together with the expensive process of optimization and water treatment, it is unlikely that the fresh produce industry would be willing to take up this technology. Furthermore, the additional one log reduction achieved by applying ultrasound to a chlorinated water wash does not completely eliminate the risk of pathogens on fresh produce.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The microbiology of minimally processed fresh fruits and vegetables
Nguyen‐the, C., & Carlin, F. (1994) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408399409527668 · Cited by 898
The microbiological safety of minimally processed vegetables
Francis, G. A., Thomas, C., & O'beirne, D. (1999) · International Journal of Food Science and Technology · doi:10.1046/j.1365-2621.1999.00253.x · Cited by 485
Minimally Processed Refrigerated Fruits & Vegetables
(1994) · Springer eBooks · doi:10.1007/978-1-4615-2393-2 · Cited by 331
Earnshaw, R. G., Appleyard, J., & Hurst, R. M. (1995) · International Journal of Food Microbiology · doi:10.1016/0168-1605(95)00057-7 · Cited by 328 · cited 1×
“The growth, collapse and oscillation of these bubbles generate the mechanical energy which has a ‘cleaning’ action on surfaces (Kinsloe et al., 1954; Roberts, 1991; Scherba et al., 1991; Schett-Abraham et al., 1992; Earnshaw et al., 1995; Sala et al., 1995; Raso et al., 1998).”
BackgroundFactors affecting the efficacy of washing procedures used in the production of prepared salads
Adams, M. R., Hartley, A. D., & Cox, L. J. (1989) · Food Microbiology · doi:10.1016/s0740-0020(89)80039-5 · Cited by 308 · cited 1×
“Nonetheless, Adams et al. (1989) indicated that chlorine and Tween 80 in combination were no more effective at decontaminating lettuce than Tween 80 alone.”
BackgroundSelf-citationQuantitative assessment of the germicidal efficacy of ultrasonic energy
Scherba, G., Weigel, R. M., & O'Brien, W. D. (1991) · Applied and Environmental Microbiology · doi:10.1128/aem.57.7.2079-2084.1991 · Cited by 305 · cited 4×
“Ultrasonic fields consist of waves at high amplitude, which form cavitation bubbles (Scherba et al., 1991).”
BackgroundInfluentialEnterohemorrhagic Escherichia coli O157:H7 Present in Radish Sprouts
Itoh, Y., Sugita-Konishi, Y., Kasuga, F., Iwaki, M., Hara-Kudo, Y., Saito, N., Noguchi, Y., Konuma, H., & Kumagai, S. (1998) · Applied and Environmental Microbiology · doi:10.1128/aem.64.4.1532-1535.1998 · Cited by 246
Effect of heat and ultrasound on microorganisms and enzymes
Sala, F. J., Burgos, J., Condón, S., Lopez, P., & Raso, J. (1995) · New Methods of Food Preservation · doi:10.1007/978-1-4615-2105-1_9 · Cited by 238
Influence of Temperature and Pressure on the Lethality of Ultrasound
Raso, J., Pagán, R., Condón, S., & Sala, F. J. (1998) · Applied and Environmental Microbiology · doi:10.1128/aem.64.2.465-471.1998 · Cited by 236 · cited 2×
“Several workers have examined the antimicrobial effects of ultrasound on bacteria (Ordonez et al., 1987; Scherba et al., 1991; Raso et al., 1998; Pagan et al., 1999), spore formers (Sanz et al.”
BackgroundPagán, R., Mañas, P., Álvarez, I., & Condón, S. (1999) · Food Microbiology · doi:10.1006/fmic.1998.0231 · Cited by 138
Cited by
Applications of ultrasound in analysis, processing and quality control of food: A review
Awad, T. S., Moharram, H. A., Shaltout, O. E., Asker, D., & Youssef, M. M. (2012) · Food Research International · doi:10.1016/j.foodres.2012.05.004 · Cited by 996
Inactivation of microbes using ultrasound: a review
Piyasena, P., Mohareb, E., & McKellar, R. C. (2003) · International Journal of Food Microbiology · doi:10.1016/s0168-1605(03)00075-8 · Cited by 886
Fresh fruits and vegetables—An overview on applied methodologies to improve its quality and safety
Ramos, B., Miller, F. A., Brandão, T. R. S., Teixeira, P., & Silva, C. L. M. (2013) · Innovative Food Science & Emerging Technologies · doi:10.1016/j.ifset.2013.07.002 · Cited by 499
Effect of ultrasonic processing on food enzymes of industrial importance
O’Donnell, C. P., Tiwari, B. K., Bourke, P., & Cullen, P. J. (2010) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2010.04.007 · Cited by 421
De Corato, U. (2020) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408398.2018.1553025 · Cited by 376
A review on recent development in non-conventional food sterilization technologies
Li, X., & Farid, M. (2016) · Journal of Food Engineering · doi:10.1016/j.jfoodeng.2016.02.026 · Cited by 342
Alternative disinfection methods to chlorine for use in the fresh-cut industry
Meireles, A., Giaouris, E., & Simões, M. (2016) · Food Research International · doi:10.1016/j.foodres.2016.01.021 · Cited by 336
Sagong, H.-G., Lee, S.-Y., Chang, P.-S., Heu, S., Ryu, S., Choi, Y.-J., & Kang, D.-H. (2011) · International Journal of Food Microbiology · doi:10.1016/j.ijfoodmicro.2011.01.010 · Cited by 328
Decontamination by ultrasound application in fresh fruits and vegetables
São José, J. F. B. D., Andrade, N. J. D., Ramos, A. M., Vanetti, M. C. D., Stringheta, P. C., & Chaves, J. B. P. (2014) · Food Control · doi:10.1016/j.foodcont.2014.04.015 · Cited by 318
Bacterial Separation and Concentration from Complex Sample Matrices: A Review
Stevens, K. A., & Jaykus, L.-A. (2004) · Critical Reviews in Microbiology · doi:10.1080/10408410490266410 · Cited by 305
Ragaert, P., Devlieghere, F., & Debevere, J. (2007) · Postharvest Biology and Technology · doi:10.1016/j.postharvbio.2007.01.001 · Cited by 301
Effects of sonication and carbonation on guava juice quality
CHENG, L., SOH, C., LIEW, S., & TEH, F. (2007) · Food Chemistry · doi:10.1016/j.foodchem.2007.02.001 · Cited by 283
Minimal processing for healthy traditional foods
ALLENDE, A., TOMASBARBERAN, F., & GIL, M. (2006) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2006.04.005 · Cited by 260
Deng, L.-Z., Mujumdar, A. S., Pan, Z., Vidyarthi, S. K., Xu, J., Zielinska, M., & Xiao, H.-W. (2020) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408398.2019.1649633 · Cited by 252
Opportunities and Challenges in Application of Ultrasound in Food Processing
Rastogi, N. K. (2011) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408391003770583 · Cited by 249
“Remaining bacteria were enumerated before and after washing to assess bacterial attachment (n = 5) (with permission from Seymour et al. (2002) Int.”
BackgroundMethodInfluentialBirmpa, A., Sfika, V., & Vantarakis, A. (2013) · International Journal of Food Microbiology · doi:10.1016/j.ijfoodmicro.2013.06.005 · Cited by 220
Decontamination efficiency of high power ultrasound in the fruit and vegetable industry, a review
Bilek, S. E., & Turantaş, F. (2013) · International Journal of Food Microbiology · doi:10.1016/j.ijfoodmicro.2013.06.028 · Cited by 185
“The application of ultrasound in fruit and vegetable washing is one of the alternative methods and is recommended for the food industry (Sapers, 2001; Seymour et al., 2002; Huang et al., 2006; Knorr et al., 2004; Alegria et al., 2009; Cao et al., 2010; Zhou et al., 2009; Elizaquivel et al., 2011; Rivera et al., 2011;…”
MethodDing, T., Ge, Z., Shi, J., Xu, Y.-T., Jones, C. L., & Liu, D.-H. (2015) · LWT - Food Science and Technology · doi:10.1016/j.lwt.2014.09.012 · Cited by 180
Scouten, A. J., & Beuchat, L. R. (2002) · Journal of Applied Microbiology · doi:10.1046/j.1365-2672.2002.01571.x · Cited by 174
“The use of ultrasound to promote decontamination of raw vegetables has been described (Seymour et al. 2001).”
Highmore, C. J., Warner, J. C., Rothwell, S. D., Wilks, S. A., & Keevil, C. W. (2018) · mBio · doi:10.1128/mbio.00540-18 · Cited by 166
Arvanitoyannis, I. S., Kotsanopoulos, K. V., & Savva, A. G. (2017) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408398.2013.860514 · Cited by 126
Metadata
- Authors
- Seymour, I. J., Burfoot, D., Smith, R. L., Cox, L. A., & Lockwood, A.
- Venue
- International Journal of Food Science and Technology
- Publisher
- Oxford University Press (OUP)
- Published
- 2002-06
- Volume
- 37
- Issue
- 5
- Pages
- 547-557
- ISSN
- 0950-5423 (ISSN-L)
- 1365-2621
- OpenAlex
- W2063736362
- Cited by
- 229
- References
- 18
- FWCI
- 5.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.