Current status of blood substitute research: towards a new paradigm
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Winslow RM (University of California, San Diego, CA, USA). Current status of blood substitute research: towards a new paradigm (Minisymposium). J Intern Med 2003; 253: 508–517. For many reasons, haemoglobin, modified to prolong its circulation time, seems to be the optimal choice for a cell‐free O 2 carrier (blood substitute) because of its capacity to reversibly bind O 2 in the lung and release it in tissue. After refining methods to prepare highly purified haemoglobin solutions and to chemically or genetically modify haemoglobin to overcome renal toxicity and to prolong retention time, a number of unwanted effects were observed in human clinical trials. These included symptoms referable to the GI tract, elevated pancreatic enzymes and hypertension, presumed to be the result of vasoconstriction. Studies on the mechanism of vasoconstriction induced by haemoglobin, using new techniques to investigate the microcirculation have led to a surprising new paradigm for the design of safe and effective solutions. These include increased O 2 affinity (low P50) and increased viscosity and oncotic pressure. These second‐generation solutions hold greater promise for clinical development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nitric oxide release accounts for the biological activity of endothelium-derived relaxing factor
Palmer, R. M. J., Ferrige, A. G., & Moncada, S. (1987) · Nature · doi:10.1038/327524a0 · Cited by 10,704
S-nitrosohaemoglobin: a dynamic activity of blood involved in vascular control
Jia, L., Bonaventura, C., Bonaventura, J., & Stamler, J. S. (1996) · Nature · doi:10.1038/380221a0 · Cited by 1,601
Chang, T. M. S. (1964) · Science · doi:10.1126/science.146.3643.524 · Cited by 1,011
DULING, B. R., & BERNE, R. M. (1970) · Circulation Research · doi:10.1161/01.res.27.5.669 · Cited by 466
Scholander, P. F. (1960) · Science · doi:10.1126/science.131.3400.585 · Cited by 446
Rate of reaction with nitric oxide determines the hypertensive effect of cell-free hemoglobin
Doherty, D. H., Doyle, M. P., Curry, S. R., Vali, R. J., Fattor, T. J., Olson, J. S., & Lemon, D. D. (1998) · Nature Biotechnology · doi:10.1038/nbt0798-672 · Cited by 432
A clinical safety trial of stroma‐free hemoglobin
Savitsky, J. P., Doczi, J., Black, J., & Arnold, J. D. (1978) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt197823173 · Cited by 359
A human recombinant haemoglobin designed for use as a blood substitute
Looker, D., Abbott-Brown, D., Cozart, P., Durfee, S., Hoffman, S., Mathews, A. J., Miller-Roehrkh, J., Shoemaker, S., Trimble, S., Fermi, G., et al. (1992) · Nature · doi:10.1038/356258a0 · Cited by 316
Microvascular and tissue oxygen distribution
Intaglietta, M. (1996) · Cardiovascular Research · doi:10.1016/0008-6363(96)00110-1 · Cited by 293
Cited by
Therapeutic applications of polymeric artificial cells
Chang, T. M. S. (2005) · Nature Reviews Drug Discovery · doi:10.1038/nrd1659 · Cited by 322
No scavenging and the hypertensive effect of hemoglobin-based blood substitutes
Olson, J. S., Foley, E. W., Rogge, C., Tsai, A.-L., Doyle, M. P., & Lemon, D. D. (2004) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2003.11.030 · Cited by 308
Oxygen therapeutics: can we tame haemoglobin?
Alayash, A. I. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1307 · Cited by 303
Moore, E. E., Moore, F. A., Fabian, T. C., Bernard, A. C., Fulda, G. J., Hoyt, D. B., Duane, T. M., Weireter, L. J., Gomez, G. A., Cipolle, M. D., et al. (2009) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2008.09.023 · Cited by 259
Polymersome Encapsulated Hemoglobin: A Novel Type of Oxygen Carrier
Arifin, D. R., & Palmer, A. F. (2005) · Biomacromolecules · doi:10.1021/bm0501454 · Cited by 192
The Redox Activity of Hemoglobins: From Physiologic Functions to Pathologic Mechanisms
Reeder, B. J. (2010) · Antioxidants & Redox Signaling · doi:10.1089/ars.2009.2974 · Cited by 189
“The first generation of HBOCs, developed during the 1980s and 1990s, was aimed at eliminating renal toxicity through prevention of Hb dimerization, thus increasing its vascular retention by decreasing renal clearance and preventing haptoglobin depletion (287).”
Red Blood Cell-Mimicking Micromotor for Active Photodynamic Cancer Therapy
Gao, C., Lin, Z., Wang, D., Wu, Z., Xie, H., & He, Q. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b07979 · Cited by 173
Metadata
- Authors
- Winslow, R. M.
- Venue
- Journal of Internal Medicine
- Publisher
- Wiley
- Published
- 2003-04-17
- Volume
- 253
- Issue
- 5
- Pages
- 508-517
- ISSN
- 0954-6820 (ISSN-L)
- 1365-2796
- OpenAlex
- W2032226735
- Cited by
- 208
- References
- 29
- FWCI
- 7.59
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.