CoChat

Segmentation of confocal microscope images of cell nuclei in thick tissue sections

Open access
ORTIZ DE SOLÓRZANO, C., GARCÍA RODRIGUEZ, E., JONES, A., PINKEL, D., GRAY, J. W., SUDAR, D., LOCKETT, S. J. · 1999 · Journal of Microscopy
Cited by 156

The DOI matches its Crossref record.

Abstract

Summary: Segmentation of intact cell nuclei from three‐dimensional (3D) images of thick tissue sections is an important basic capability necessary for many biological research studies. However, segmentation is often difficult because of the tight clustering of nuclei in many specimen types. We present a 3D segmentation approach that combines the recognition capabilities of the human visual system with the efficiency of automatic image analysis algorithms. The approach first uses automatic algorithms to separate the 3D image into regions of fluorescence‐stained nuclei and unstained background. This includes a novel step, based on the Hough transform and an automatic focusing algorithm to estimate the size of nuclei. Then, using an interactive display, each nuclear region is shown to the analyst, who classifies it as either an individual nucleus, a cluster of multiple nuclei, partial nucleus or debris. Next, automatic image analysis based on morphological reconstruction and the watershed algorithm divides clusters into smaller objects, which are reclassified by the analyst. Once no more clusters remain, the analyst indicates which partial nuclei should be joined to form complete nuclei. The approach was assessed by calculating the fraction of correctly segmented nuclei for a variety of tissue types:Caenorhabditis elegans embryos (839 correct out of a total of 848), normal human skin (343/362), benign human breast tissue (492/525), a human breast cancer cell line grown as a xenograft in mice (425/479) and invasive human breast carcinoma (260/335). Furthermore, due to the analyst's involvement in the segmentation process, it is always known which nuclei in a population are correctly segmented and which not, assuming that the analyst's visual judgement is correct.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1365-2818.1999.00463.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 156

Metadata

Authors
ORTIZ DE SOLÓRZANO, C., GARCÍA RODRIGUEZ, E., JONES, A., PINKEL, D., GRAY, J. W., SUDAR, D., & LOCKETT, S. J.
Venue
Journal of Microscopy
Publisher
Wiley
Published
1999-03
Volume
193
Issue
3
Pages
212-226
ISSN
  • 0022-2720 (ISSN-L)
  • 1365-2818
OpenAlex
W2039490988
Cited by
156
References
0
FWCI
3.77
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Segmentation of confocal microscope images of cell nuclei in thick tissue sections. https://app.cochat.ai/papers/10.1046/j.1365-2818.1999.00463.x
The paper
ORTIZ DE SOLÓRZANO, C., GARCÍA RODRIGUEZ, E., JONES, A., PINKEL, D., GRAY, J. W., SUDAR, D., & LOCKETT, S. J. (1999). Segmentation of confocal microscope images of cell nuclei in thick tissue sections. Journal of Microscopy. https://doi.org/10.1046/j.1365-2818.1999.00463.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.