CoChat

Effect of low and high frequency thalamic stimulation on sleep in patients with Parkinson's disease and essential tremor

Arnulf, Isabelle, Bejjani, Boulos‐Paul, Garma, Lucile, Bonnet, Anne‐Marie, Damier, Philippe, Pidoux, Bernard, Dormont, Didier, Cornu, Philippe, Derenne, Jean‐Philippe, Agid, Yves · 2000 · Journal of Sleep Research
Cited by 37

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

SUMMARY: Continuous high frequency stimulation of the ventral intermediate nucleus of the thalamus (Vim), delivered through surgically implanted quadripolar electrodes, alleviates tremor in Parkinson's disease (PD) and essential tremor (ET). The Vim is adjacent to the thalamic reticular nuclei, where sleep spindles originate according to animal models. In order to determine whether Vim stimulation affects sleep spindles, six patients (4 PD, 2 ET), aged 60–69 years, were recorded on a control night and a stimulation night (130 Hz, 2–3 V; right stimulation in five patients and bilateral stimulation in one patient). Stimulation did not modify sleep quality or architecture. Sleep spindles were present and symmetrical in five out of six patients under stimulation. However, in one patient with a sustained ‘thalamotomy‐like effect’ that abolished tremor, spindles were asymmetrical even without stimulation. In each patient, spindle density was similar on both nights (mean± SEM: 2.25±0.61 spindles per min of stage 2 sleep vs. 1.84±0.31). In an attempt to promote sleep two different patterns of stimulation were applied in the region of ventrooralis posterior and reticularis nuclei in five patients in the awake state. Continuous low frequency stimulation (5 Hz, 0.1 V), and repeated trains of 15 Hz for 1 s every 15 s mimicking the pattern of physiological spindles, each failed to induce sleep or cortical synchronization. We conclude that Vim stimulation, unlike thalamotomy, selectively reduces tremor without altering sleep or sleep spindles. Our results also suggest that low frequency stimulation applied in the region of the reticular nuclei does not induce sleep.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1365-2869.2000.00171.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 37

Metadata

Authors
Arnulf, I., Bejjani, B., Garma, L., Bonnet, A., Damier, P., Pidoux, B., Dormont, D., Cornu, P., Derenne, J., & Agid, Y.
Venue
Journal of Sleep Research
Publisher
Wiley
Published
2000-03
Volume
9
Issue
1
Pages
55-62
ISSN
  • 0962-1105 (ISSN-L)
  • 1365-2869
OpenAlex
W2089658128
Cited by
37
References
3
FWCI
1.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of low and high frequency thalamic stimulation on sleep in patients with Parkinson's disease and essential tremor. https://app.cochat.ai/papers/10.1046/j.1365-2869.2000.00171.x
The paper
Arnulf, I., Bejjani, B., Garma, L., Bonnet, A., Damier, P., Pidoux, B., Dormont, D., Cornu, P., Derenne, J., & Agid, Y. (2000). Effect of low and high frequency thalamic stimulation on sleep in patients with Parkinson's disease and essential tremor. Journal of Sleep Research. https://doi.org/10.1046/j.1365-2869.2000.00171.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.