Interrater reliability between scorers from eight European sleep laboratories in subjects with different sleep disorders
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Summary: Interrater variability of sleep stage scorings is a well‐known phenomenon. The SIESTA project offered the opportunity to analyse interrater reliability (IRR) between experienced scorers from eight European sleep laboratories within a large sample of patients with different (sleep) disorders: depression, general anxiety disorder with and without non‐organic insomnia, Parkinson's disease, period limb movements in sleep and sleep apnoea. The results were based on 196 recordings from 98 patients (73 males: 52.3 ± 12.1 years and 25 females: 49.5 ± 11.9 years) for which two independent expert scorings from two different laboratories were available. Cohen's κ was used to evaluate the IRR on the basis of epochs and intraclass correlation was used to analyse the agreement on quantitative sleep parameters. The overall level of agreement when five different stages were distinguished was κ = 0.6816 (76.8%), which in terms of κ reflects a ‘substantial’ agreement (Landis and Koch, 1977). For different groups of patients κ values varied from 0.6138 (Parkinson's disease) to 0.8176 (generalized anxiety disorder). With regard to (sleep) stages, the IRR was highest for rapid eye movement (REM), followed by Wake, slow‐wave sleep (SWS), non‐rapid eye movement 2 (NREM2) and NREM1. The results of regression analysis showed that age and sex only had a statistically significant effect on κ when the (sleep) stages are considered separately. For NREM2 and SWS a statistically significant decrease of IRR with age has been observed and the IRR for SWS was lower for males than for females. These variations of IRR most probably reflect changes of the sleep electroencephalography (EEG) with age and gender.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148 · cited 4×
“The overall level of agreement when five different stages were distinguished was j ¼ 0.6816 (76.8%), which in terms of j reflects a ‘substantial’ agreement (Landis and Koch, 1977).”
BackgroundMethodInfluentialRechtschaffen, A. (1968) · Medical Entomology and Zoology · Cited by 12,675
The Effects of Coffee and Napping on Nighttime Highway Driving: A Randomized Trial
Philip, P., Taillard, J., Moore, N., Delord, S., Valtat, C., Sagaspe, P., & Bioulac, B. (2006) · Annals of Internal Medicine · doi:10.7326/0003-4819-144-11-200606060-00004 · Cited by 650
Carrier, J., Land, S., Buysse, D. J., Kupfer, D. J., & Monk, T. H. (2001) · Psychophysiology · doi:10.1111/1469-8986.3820232 · Cited by 494
A simple format for exchange of digitized polygraphic recordings
Kemp, B., Värri, A., Rosa, A. C., Nielsen, K. D., & Gade, J. (1992) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(92)90009-7 · Cited by 370 · cited 1×
“For the exchange of the digital polygraphic sleep data and the documentation of the hypnograms, the EDF data format (Kemp et al. 1992) was used.”
MethodSelf-citationSleep and morningness‐eveningness in the ‘middle’ years of life (20–59y)
CARRIER, J., MONK, T. H., BUYSSE, D. J., & KUPFER, D. J. (1997) · Journal of Sleep Research · doi:10.1111/j.1365-2869.1997.00230.x · Cited by 303 · cited 2×
“There is clear evidence that polysomnographic sleep parameters vary significantly with age (Carrier et al. 1997, 2001; Ehlers and Kupfer 1989; Rappelsberger et al. 2001; Riemann et al. 1994) in healthy subjects and in patients with depression (Riemann et al. 1994).”
BackgroundInterobserver Agreement Among Sleep Scorers From Different Centers in a Large Dataset
Norman, R. G., Pal, I., Stewart, C., Walsleben, J. A., & Rapoport, D. M. (2000) · Sleep · doi:10.1093/sleep/23.7.1e · Cited by 246 · cited 4×
“There are two studies in which interrater agreement between human scorers was analysed by means of j coefficients: Norman et al. (2000) and Penzel et al. (2003).”
BackgroundMethodInfluentialDipole models of eye movements and blinks
Berg, P., & Scherg, M. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90154-v · Cited by 200
The SIESTA project polygraphic and clinical database
Klosh, G., Kemp, B., Penzel, T., Schlogl, A., Rappelsberger, P., Trenker, E., Gruber, G., Zeithofer, J., Saletu, B., Herrmann, W. M., et al. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.932725 · Cited by 187 · cited 1×
“The European SIESTA project (Klösch et al. 2001; Rappelsberger et al. 2001) offers the opportunity to analyse interrater agreement between experienced scorers from eight European sleep laboratories on a large sample of healthy subjects (n 1⁄4 198) and patients (n 1⁄4 98) with different sleep disorders.”
BackgroundSelf-citationLimitations of Rechtschaffen and Kales
Himanen, S.-L., & Hasan, J. (2000) · Sleep Medicine Reviews · doi:10.1053/smrv.1999.0086 · Cited by 173 · cited 3×
“Inspite of the preliminary nature of this sleep stage scoring manual and the growing criticism (Himanen and Hasan 2000; Kubicki and Herrmann 1996; Kubicki et al. 1985), the criteria have ever since that time been used as gold standard of sleep stage scoring and the rules have been applied to the…”
MethodSelf-citation
Cited by
The visual scoring of sleep in adults
Silber, M. H., Ancoli-Israel, S., Bonnet, M. H., Chokroverty, S., Grigg-Damberger, M. M., Hirshkowitz, M., Kapen, S., Keenan, S. A., Kryger, M. H., Penzel, T., et al. (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.26814 · Cited by 1,064
Self-citationDANKER‐HOPFE, H., ANDERER, P., ZEITLHOFER, J., BOECK, M., DORN, H., GRUBER, G., HELLER, E., LORETZ, E., MOSER, D., PARAPATICS, S., et al. (2009) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2008.00700.x · Cited by 417
Self-citationCharacterization of four-class motor imagery EEG data for the BCI-competition 2005
Schlögl, A., Lee, F., Bischof, H., & Pfurtscheller, G. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/l02 · Cited by 414
Self-citationMoser, D., Anderer, P., Gruber, G., Parapatics, S., Loretz, E., Boeck, M., Kloesch, G., Heller, E., Schmidt, A., Danker-Hopfe, H., et al. (2009) · Sleep · doi:10.1093/sleep/32.2.139 · Cited by 396
Self-citationAutomatic Analysis of Single-Channel Sleep EEG: Validation in Healthy Individuals
Berthomier, C., Drouot, X., Herman-Stoïca, M., Berthomier, P., Prado, J., Bokar-Thire, D., Benoit, O., Mattout, J., & d'Ortho, M.-P. (2007) · Sleep · doi:10.1093/sleep/30.11.1587 · Cited by 294
Anderer, P., Gruber, G., Parapatics, S., Woertz, M., Miazhynskaia, T., Klösch, G., Saletu, B., Zeitlhofer, J., Barbanoj, M. J., Danker-Hopfe, H., et al. (2005) · Neuropsychobiology · doi:10.1159/000085205 · Cited by 284
Self-citationExperimental Evidence for Phase Synchronization Transitions in the Human Cardiorespiratory System
Bartsch, R., Kantelhardt, J. W., Penzel, T., & Havlin, S. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.054102 · Cited by 203
Self-citationNoise emitted from road, rail and air traffic and their effects on sleep
Griefahn, B., Marks, A., & Robens, S. (2006) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2005.12.052 · Cited by 183
“Each of two experienced evaluators with an excellent inter-rater reliability (490% [10]) rated the nights of 16 participants, balanced according to gender and experimental conditions.”
BackgroundInterrater reliability of sleep stage scoring: a meta-analysis
Lee, Y. J., Lee, J. Y., Cho, J. H., & Choi, J. H. (2022) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.9538 · Cited by 174
“7,10,28 In this analysis, we focused on Cohen ’ s k ; this is the preferred method of reliability estimation when using categorical variables.”
A review of automated sleep stage scoring based on physiological signals for the new millennia
Faust, O., Razaghi, H., Barika, R., Ciaccio, E. J., & Acharya, U. R. (2019) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2019.04.032 · Cited by 170
Rethinking Sleep Analysis: Comment on the AASM Manual for the Scoring of Sleep and Associated Events
Schulz, H. (2008) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27124 · Cited by 165
Interrater reliability of EEG-video monitoring
Benbadis, S. R., LaFrance, W. C., Papandonatos, G. D., Korabathina, K., Lin, K., & Kraemer, H. C. (2009) · Neurology · doi:10.1212/wnl.0b013e3181b78425 · Cited by 165
The AASM Scoring Manual Four Years Later
Grigg-Damberger, M. M. (2012) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1928 · Cited by 162
An end-to-end framework for real-time automatic sleep stage classification
Patanaik, A., Ong, J. L., Gooley, J. J., Ancoli-Israel, S., & Chee, M. W. L. (2018) · Sleep · doi:10.1093/sleep/zsy041 · Cited by 162
“This assessment was arrived at through evaluation by an independent set of sleep technicians and reflects achievement of an accuracy level consistent with prior reports [36].”
BackgroundResultAutomatic Human Sleep Stage Scoring Using Deep Neural Networks
Malafeev, A., Laptev, D., Bauer, S., Omlin, X., Wierzbicka, A., Wichniak, A., Jernajczyk, W., Riener, R., Buhmann, J., & Achermann, P. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00781 · Cited by 151
Myllymaa, S., Muraja‐Murro, A., Westeren‐Punnonen, S., Hukkanen, T., Lappalainen, R., Mervaala, E., Töyräs, J., Sipilä, K., & Myllymaa, K. (2016) · Journal of Sleep Research · doi:10.1111/jsr.12425 · Cited by 66
Ghorbani, S., Golkashani, H. A., Chee, N. I., Teo, T. B., Dicom, A. R., Yilmaz, G., Leong, R. L., Ong, J. L., & Chee, M. W. (2022) · Nature and Science of Sleep · doi:10.2147/nss.s359789 · Cited by 36
Auto bi-level pressure relief–PAP is as effective as CPAP in OSA patients—a pilot study
Blau, A., Minx, M., Peter, J. G., Glos, M., Penzel, T., Baumann, G., & Fietze, I. (2012) · Sleep and Breathing · doi:10.1007/s11325-011-0574-1 · Cited by 32
“Sleep stages were scored according to Rechtschaffen and Kales by two experts to minimize intrascorer variability [12].”
MethodSelf-citationAutomatic sleep classification according to Rechtschaffen and Kales
Anderer, P., Gruber, G., Parapatics, S., & Dorffner, G. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4353209 · Cited by 21
Self-citation
Metadata
- Authors
- Danker‐Hopfe, H., Kunz, D., Gruber, G., Klösch, G., Lorenzo, J. L., Himanen, S. L., Kemp, B., Penzel, T., Röschke, J., Dorn, H., Schlögl, A., Trenker, E., & Dorffner, G.
- Venue
- Journal of Sleep Research
- Publisher
- Wiley
- Published
- 2004-02-23
- Volume
- 13
- Issue
- 1
- Pages
- 63-69
- ISSN
- 0962-1105 (ISSN-L)
- 1365-2869
- OpenAlex
- W1689369912
- Cited by
- 217
- References
- 26
- FWCI
- 10.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.