CoChat

Rectal visceral sensitivity in healthy volunteers: influences of gender, age and methods

Sloots, Felt‐Bersma, Cuesta, Meuwissen · 2000 · Neurogastroenterology & Motility
Cited by 81

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The barostat is a device that maintains a constant pressure within an air‐filled polyethylene bag by means of a feedback mechanism. The system measures variations in rectal tone by recording changes in the intrarectal pressure and volume. Different procedures, such as ramp distension or intermittent distension, are used to test visceral sensitivity and rectal wall compliance. It is not quite clear which method is preferable and how the barostat measurements compare with those of the conventional latex balloon. In 28 healthy volunteers (11 males, mean age 36, range 22–67 years) rectal distension was performed in two ways: 1 Pressure‐controlled distension, by both intermittent and ramp methods, with measurement on the Visual Analogue Scale (VAS, 0–5) at 8, 12, 16, 20, 24, 28, 32 and 36 mmHg. Hysteresis (comparing area under the curve during deflation and inflation with ramp pressure distension) and compliance were calculated. 2 Volume‐controlled distension, with registration of first sensation, urge to defecate and maximal tolerated distension. This procedure was compared to conventional water‐filled latex balloon distension. No differences were found between intermittent and ramp distension comparing VAS scores at the same pressures. Gender or age did not affect the VAS score. Males had larger volumes at the same pressures than females. Females had larger hysteresis than males. Older females had larger hysteresis than younger females. The pressure volume curves were S‐shaped. Compliance at maximal tolerated distension (V/p) and maximal dynamic compliance (ΔV/Δp) was higher in males than females. The polyethylene bag had higher MTV and MTP compared to the latex balloon. In conclusion, no differences were found in volumes, compliance or VAS between the intermittent and the ramp pressure‐controlled inflation, indicating potential for simplification of the procedure. Males had larger rectal volumes and compliances; females had more pronounced hysteresis. A systemic difference was found between distension with the water‐filled latex balloon and with the air‐filled polyethylene bag. This should be taken into account when interpreting results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1365-2982.2000.00210.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 81

Metadata

Authors
Sloots, Felt‐Bersma, Cuesta, & Meuwissen
Venue
Neurogastroenterology & Motility
Publisher
Wiley
Published
2000-08
Volume
12
Issue
4
Pages
361-368
ISSN
  • 1350-1925 (ISSN-L)
  • 1365-2982
OpenAlex
W1970190599
Cited by
81
References
3
FWCI
4.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.