The DOI matches its Crossref record.
Relation Between the Pacing Induced Sequence of Activation and Left Ventricular Pump Function in Animals
Abstract
PRINZEN, F.W., et al.: Relation Between the Pacing Induced Sequence of Activation and Left Ventricu‐lar Pump Function in Animals. The main goal of this article was to review animal experimental work on the effect of asynchronous activation on ventricular pump function. During normal sinus rhythm and atrial pacing, the Purkinje system contributes significantly to the rapid electrical activation of the ventricles. In contrast, during ventricular pacing the impulse is almost exclusively conducted through the normal myocardium. As a consequence, electrical activation of the ventricles becomes asynchronous and has an abnormal sequence. The abnormal impulse conduction causes considerable disturbances to occur in regional systolic fiber shortening, mechanical work, blood flow, and oxygen consumption; low values occurring in early activated regions and values above normal being present in late activated regions. Many animal studies have now shown that the abnormal electrical activation, induced by ventricular pacing, leads to a depression of systolic and diastolic LV function. Pacing at the right ventricular apex (the conventional pacing site) reduces LV function more than pacing at the high ventricular septum or at LV sites. In canine hearts with experimental LBBB, LV pacing significantly improves LV pump function. Differences in LV pump function between (combinations of) pacing sites are poorly correlated with QRS duration. Therefore, the cause of the depression of LV function during abnormal electrical activation appears to be a combination of the asynchrony and the sequence of activation. These experimental findings justify continuing attention for optimizing the site(s) of ventricular pacing in patients with normal and abnormal ventricular impulse conduction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Minimizing Ventricular Pacing to Reduce Atrial Fibrillation in Sinus-Node Disease
Sweeney, M. O., Bank, A. J., Nsah, E., Koullick, M., Zeng, Q. C., Hettrick, D., Sheldon, T., & Lamas, G. A. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa071880 · Cited by 520
The Effects of Right Ventricular Apical Pacing on Ventricular Function and Dyssynchrony
Tops, L. F., Schalij, M. J., & Bax, J. J. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.06.006 · Cited by 430
Lipshultz, S. E., Law, Y. M., Asante-Korang, A., Austin, E. D., Dipchand, A. I., Everitt, M. D., Hsu, D. T., Lin, K. Y., Price, J. F., Wilkinson, J. D., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000682 · Cited by 416
Sengupta, P. P., Krishnamoorthy, V. K., Korinek, J., Narula, J., Vannan, M. A., Lester, S. J., Tajik, J. A., Seward, J. B., Khandheria, B. K., & Belohlavek, M. (2007) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2006.10.013 · Cited by 323
Heart Failure During Cardiac Pacing
Sweeney, M. O., & Hellkamp, A. S. (2006) · Circulation · doi:10.1161/circulationaha.105.608356 · Cited by 252
Metadata
- Authors
- PRINZEN, F. W., & PESCHAR, M.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2002-04
- Volume
- 25
- Issue
- 4
- Pages
- 484-498
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2059523482
- Cited by
- 286
- References
- 0
- FWCI
- 5.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relation Between the Pacing Induced Sequence of Activation and Left Ventricular Pump Function in Animals. https://app.cochat.ai/papers/10.1046/j.1460-9592.2002.00484.x
- The paper
- PRINZEN, F. W., & PESCHAR, M. (2002). Relation Between the Pacing Induced Sequence of Activation and Left Ventricular Pump Function in Animals. Pacing and Clinical Electrophysiology. https://doi.org/10.1046/j.1460-9592.2002.00484.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.