A new air displacement plethysmograph for the determination of Japanese body composition
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Summary: A new device based on the plethysmographic measurement of body volume, named the BOD POD Body Composition System, was developed for the purpose of estimating body composition. The performance, reliability, validity, and clinical application of this system were evaluated in Japanese subjects. The coefficient variation (CV:%) in same‐day tests was 2.48, in three separate‐day tests it was 2.27, and for independent operators it was 4.53, respectively. There was a clear correlation between the results from BOD POD and those from dual energy X‐ray absorptiometry (DEXA) (r = 0.910, p < 0.01). Finally, the fat body composition of 4489 subjects (1499 men, 2990 women) was clinically measured by BOD POD. The findings indicate that the BOD POD is a highly reliable and valid method for determining body fat percentage. This new method has several advantages, e.g. it is quick, simple to operate and may accommodate wide populations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Validation of tetrapolar bioelectrical impedance method to assess human body composition
Lukaski, H. C., Bolonchuk, W. W., Hall, C. B., & Siders, W. A. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.4.1327 · Cited by 1,370
A new air displacement method for the determination of human body composition
DEMPSTER, P., & AITKENS, S. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199512000-00017 · Cited by 678
Cited by
ESMO Symposium on Immuno-Oncology 2015 Officers and Organisation
(2015) · Annals of Oncology · doi:10.1093/annonc/ · Cited by 733
Body-composition assessment via air-displacement plethysmography in adults and children: a review
Fields, D. A., Goran, M. I., & McCrory, M. A. (2002) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/75.3.453 · Cited by 638
Hepatic Cytochrome P450 2E1 Activity in Nondiabetic Patients With Nonalcoholic Steatohepatitis
Chalasani, N., Gorski, C. J., Asghar, M. S., Asghar, A., Foresman, B., Hall, S. D., & Crabb, D. W. (2003) · Hepatology · doi:10.1053/jhep.2003.50095 · Cited by 348
Contemporary methods of body composition measurement
Fosbøl, M. Ø., & Zerahn, B. (2015) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12152 · Cited by 279
Comparison of Methods to Assess Body Composition Changes during a Period of Weight Loss
Frisard, M. I., Greenway, F. L., & DeLany, J. P. (2005) · Obesity Research · doi:10.1038/oby.2005.97 · Cited by 153
Metadata
- Authors
- Miyatake, N., Nonaka, K., & Fujii, M.
- Venue
- Diabetes, Obesity and Metabolism
- Publisher
- Wiley
- Published
- 1999-11
- Volume
- 1
- Issue
- 6
- Pages
- 347-351
- ISSN
- 1462-8902 (ISSN-L)
- 1463-1326
- OpenAlex
- W2029609557
- Cited by
- 64
- References
- 3
- FWCI
- 0.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.