The DOI matches its Crossref record.
A comparison between ultrasound and a reliable last menstrual period as predictors of the day of delivery in 15 000 examinations
Open accessAbstract
In a non‐selected population comprising 1.5 241 women, an evaluation was performed of the ultrasonic measurement of the biparietal diameter compared with a reliable last menstrual period as the basis for estimation of the day of delivery. In women with a reliable menstrual history and spontaneous onset of labor, the ultrasound estimate was the significantly better predictor of the day of delivery in 52% of cases, and the last menstrual period estimate was the better predictor in 46% of cases. The percentages of women who delivered within 7 days of the predicted day were 61 and 56% for the ultrasound and the last menstrual period estimations, respectively. There was a significantly narrower distribution of births according to the ultrasound estimate (p < 0.001). The proportion of estimated post‐term births was 4% using the ultrasound method and 10% using the last menstrual period method (p < 0.001). Even when the difference between the methods in predicting the day of delivery was less than 7 days, the ultrasound method was better than the last menstrual period method. It is concluded that ultrasonic measurement of the biparietal diameter between 15 and 22 weeks of pregnancy is the best method for the estimation of the day of delivery and should be used as a routine procedure. Copyright © 1996 International Society of Ultrasound in Obstetrics and Gynecology
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Generation R Study: design and cohort update 2010
Jaddoe, V. W. V., van Duijn, C. M., van der Heijden, A. J., Mackenbach, J. P., Moll, H. A., Steegers, E. A. P., Tiemeier, H., Uitterlinden, A. G., Verhulst, F. C., & Hofman, A. (2010) · European Journal of Epidemiology · doi:10.1007/s10654-010-9516-7 · Cited by 1,027
Practice guidelines for performance of the routine mid-trimester fetal ultrasound scan
Salomon, L. J., Alfirevic, Z., Berghella, V., Bilardo, C., Hernandez‐Andrade, E., Johnsen, S. L., Kalache, K., Leung, K. ‐., Malinger, G., Munoz, H., et al. (2011) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.8831 · Cited by 1,006
Prolonged and Exclusive Breastfeeding Reduces the Risk of Infectious Diseases in Infancy
Duijts, L., Jaddoe, V. W. V., Hofman, A., & Moll, H. A. (2010) · Pediatrics · doi:10.1542/peds.2008-3256 · Cited by 682
Verburg, B. O., Steegers, E. A. P., De Ridder, M., Snijders, R. J. M., Smith, E., Hofman, A., Moll, H. A., Jaddoe, V. W. V., & Witteman, J. C. M. (2008) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.5225 · Cited by 506
ÃdegÃ¥rd, R. (2000) · Obstetrics & Gynecology · doi:10.1016/s0029-7844(00)01040-1 · Cited by 432
Metadata
- Authors
- Tunón, K., Eik‐Nes, S. H., & Grøttum, P.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 1996-09
- Volume
- 8
- Issue
- 3
- Pages
- 178-185
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2076652001
- Cited by
- 159
- References
- 0
- FWCI
- 2.68
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comparison between ultrasound and a reliable last menstrual period as predictors of the day of delivery in 15 000 examinations. https://app.cochat.ai/papers/10.1046/j.1469-0705.1996.08030178.x
- The paper
- Tunón, K., Eik‐Nes, S. H., & Grøttum, P. (1996). A comparison between ultrasound and a reliable last menstrual period as predictors of the day of delivery in 15 000 examinations. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1046/j.1469-0705.1996.08030178.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.