Fetal weight estimation by three‐dimensional ultrasound
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Objective: To assess the value of three‐dimensional volume scanning in predicting fetal weight at birth. Study design: Prospective cross‐sectional study within 7 days of delivery. A total of 190 patients were considered for final analysis (formula‐finding group: n = 125, formula evaluation group: n = 65). Inclusion criteria were a singleton pregnancy and absence of chromosomal or significant structural anomalies. Three‐dimensional (3D) volumetric measurements of the fetal thigh, upper arm and abdomen were performed together with conventional two‐dimensional (2D) biometry. Results: All measurements were completed successfully in each patient. Polynomial regression analysis with standard biometric parameters and volumes of the upper arm, the thigh and the abdomen was employed to yield the best‐fit formula for prediction of fetal weight at birth. The new 3D formula (estimated fetal weight (EFW) = −1478.557 + 7.242 × thigh volume + 13.309 × upper arm volume + 852.998 × log 10 abdominal volume + 0.526 × BPD 3) proved to be superior to established 2D equations with the lowest mean error (25.8 ± 194.4 g), the lowest mean absolute error (155.2 ± 118.2 g) and the lowest mean absolute percentage error (6.1 ± 5.0%) when studied prospectively in the evaluation group. Conclusion: 3D sonography allows superior fetal weight estimation by including soft tissue volume. Further studies at the extremes of fetal weight are needed to confirm the value of our formula in these subsets. Copyright © 2000 International Society of Ultrasound in Obstetrics and Gynecology
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
Cited by
Applying the right statistics: analyses of measurement studies
Bland, J. M., & Altman, D. G. (2003) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.122 · Cited by 1,311
A systematic review of the ultrasound estimation of fetal weight
Dudley, N. J. (2005) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.1751 · Cited by 537
Defining normal and abnormal fetal growth: promises and challenges
Zhang, J., Merialdi, M., Platt, L. D., & Kramer, M. S. (2010) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2009.10.889 · Cited by 264
Preventing low birth weight: is prenatal care the answer?
Lu, M. C., Tache, V., Alexander, G. R., Kotelchuck, M., & Halfon, N. (2003) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/713605924 · Cited by 178
Three-dimensional ultrasound imaging
Prager, R. W., Ijaz, U. Z., Gee, A. H., & Treece, G. M. (2010) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/09544119jeim586 · Cited by 162
Metadata
- Authors
- Schild, R. L., Fimmers, R., & Hansmann, M.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2000-10
- Volume
- 16
- Issue
- 5
- Pages
- 445-452
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2056071786
- Cited by
- 128
- References
- 2
- FWCI
- 7.11
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.