Visualisation of three‐dimensional microcracks in compact bone
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Microdamage in bone contributes to the loss of bone quality in osteoporosis and is thought to play a major role in both fragility and stress fractures (Schaffler et al. 1995). In this study, in vivo microcracks in human ribs were bulk‐stained in basic fuchsin and viewed in longitudinal section and in 3 dimensions using 2 different computer‐based methods of reconstruction: (1) serial sectioning of methylmethacrylate embedded sections using a sledge macrotome and identification of microcracks using UV epifluorescence followed by computerised reconstruction of microcracks using software and (2) laser scanning confocal microscopy of thick sections followed by reconstruction of microcracks into a 3‐D image. The size and shape of microcracks were found to be similar using both techniques. Both techniques of reconstruction showed microcracks to be approximately elliptical in shape. From the serial sectioning reconstructions (n = 9), microcracks were found to have a mean length of 404±145 μm (mean±S.D.) (in the longitudinal direction) and mean width of 97±38 μm (in the transverse direction). Using epifluorescence microscopy, 92 microcracks were identified; mean microcrack length was 349±100 μm in the longitudinal direction. This was consistent with other results (Burr & Martin, 1993) and with the theoretical prediction of an elliptical crack shape with aspect ratio (longitudinal∶transverse) of 5∶1 deduced from analysis of random 2‐D sections (Taylor & Lee, 1998). The results obtained provide new data on the nature of microcracks in bone and the method has the potential to become a useful tool in the calculation of stress intensity values which indicate the probability of an individual microcrack propagating to cause a stress or fragility fracture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bone remodeling in response to in vivo fatigue microdamage
Burr, D. B., Martin, R. B., Schaffler, M. B., & Radin, E. L. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90204-0 · Cited by 765
Mechanical and morphological effects of strain rate on fatigue of compact bone
Schaffler, M. B., Radin, E. L., & Burr, D. B. (1989) · Bone · doi:10.1016/8756-3282(89)90055-0 · Cited by 338
Failure mechanisms in human vertebral cancellous bone
Fyhrie, D. P., & Schaffler, M. B. (1994) · Bone · doi:10.1016/8756-3282(94)90900-8 · Cited by 215
Cited by
Bone adaptation to load: microdamage as a stimulus for bone remodelling
Lee, T. C., Staines, A., & Taylor, D. (2002) · Journal of Anatomy · doi:10.1046/j.1469-7580.2002.00123.x · Cited by 225
“Mean Cr Le of 49 µ m (SR: 10 µ m) is similar to reported data (Burr & Stafford, 1990; Lee et al. 1998; O’Brien et al. 2000) for transverse sections in human rib.”
MethodResultSelf-citationTrabecular bone microdamage and microstructural stresses under uniaxial compression
Nagaraja, S., Couse, T. L., & Guldberg, R. E. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.013 · Cited by 220
“This approach has been used to identify two naturally occurring forms of in vivo microdamage: discrete linear microcracks often in a cross-hatched pattern and regions of diffuse damage (Frost, 1960; Burr and Stafford, 1990; Burr and Hooser, 1995; O’Brien et al., 2000).”
MethodThe effect of bone microstructure on the initiation and growth of microcracks
O'Brien, F. J., Taylor, D., & Lee, T. C. (2005) · Journal of Orthopaedic Research · doi:10.1016/j.orthres.2004.08.005 · Cited by 211
Self-citationMicrocrack accumulation at different intervals during fatigue testing of compact bone
O’Brien, F. J., Taylor, D., & Lee, T. C. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00066-6 · Cited by 210
“O’Brien et al. / Journal of Biomechanics 36 (2003) 973–980 975”
MethodResultSelf-citationBone remodelling algorithms incorporating both strain and microdamage stimuli
McNamara, L. M., & Prendergast, P. J. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.05.007 · Cited by 200
“Alternatively microdamage may cause apoptotic death of the osteocyte and in turn signal removal of the osteocyte and initiate a repair process ( Noble, 2003 ).”
Background
Metadata
- Authors
- O'BRIEN, F. J., TAYLOR, D., DICKSON, G. R., & LEE, T. C.
- Venue
- Journal of Anatomy
- Publisher
- Wiley
- Published
- 2000-10
- Volume
- 197
- Issue
- 3
- Pages
- 413-420
- ISSN
- 0021-8782 (ISSN-L)
- 1469-7580
- OpenAlex
- W2099525026
- Cited by
- 127
- References
- 3
- FWCI
- 3.55
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.