Nanomechanical properties and mineral concentration in articular calcified cartilage and subchondral bone
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
We studied articular calcified cartilage (ACC) and the immediately subchondral bone (SCB) in normal and osteoarthritic human femoral heads. Thick slices of human normal reference post mortem (PM) and osteoarthritic (OA) femoral heads (age 55–89 years) were embedded in PMMA, micromilled, carbon coated and studied using quantitative backscattered electron (qBSE) imaging to determine variations in degree of mineralization. With exact microanatomical location, nanoindentation was performed on the same block faces in representative superior (more highly loaded) and medial regions of the joint surface. Using a partial unloading method, elastic modulus as a function of indenter penetration depth was determined using a spherical tipped diamond indenter. A pointed indenter was used to determine the tissue hardness in selected locations. The relationship between mineralization and indentation modulus was more distinct in ACC than in SCB, the latter having a higher matrix concentration with variable collagen orientation. In OA, the bulk of the measurements were coincident with those in the PM samples, although there was a greater range in the levels of mineralization and modulus in ACC. In OA, extremely hypermineralized ACC was found in ACC proper, especially in superior regions, and translocated into SCB and hyaline cartilage. The very highly mineralized cartilage fragments may function as a hard grinding abrasive, accelerating wear rates whether attached to or fragmented from the eburnated surfaces of OA ACC. Highly mineralized regions would also alter loading patterns and thereby contribute to further destruction of the joint tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oliver, W. C., & Pharr, G. M. (1992) · Journal of Materials Research · doi:10.1557/jmr.1992.1564 · Cited by 26,961 · cited 2×
“…with a tool that measures the deformation of a loaded region in a surface matched our requirements in the ‘nanoindentation’ range (Bell et al. 1992; Oliver & Pharr, 1992; Field & Swain, 1993; Rho et al. 1997, 1999; Lee et al. 1998; Zysset et al. 1998; Bushby, 2001). qBSE was used to measure the…”
MethodZysset, P. K., Edward Guo, X., Edward Hoffler, C., Moore, K. E., & Goldstein, S. A. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00111-6 · Cited by 1,006 · cited 1×
“Hardness values for SCB are comparable with those reported previously by Rho et al. (1997, 1999) and Zysset et al. (1999).”
Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation
Rho, J.-Y., Tsui, T. Y., & Pharr, G. M. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00073-2 · Cited by 924 · cited 3×
“Hardness values for SCB are comparable with those reported previously by Rho et al. (1997, 1999) and Zysset et al. (1999). Progressing from the HAC–ACC interface to the SCB (Figs 4a and 10), tidemarks are shown as a step increase in mineralization that is apparent in both hardness (30%) and indentation modulus (50%).”
MethodThe Mechanical Adaptations of Bones
Currey, J. D. (1984) · Princeton University Press eBooks · doi:10.1515/9781400853724 · Cited by 896
Nanoindentation mapping of the mechanical properties of human molar tooth enamel
Cuy, J. L., Mann, A. B., Livi, K. J., Teaford, M. F., & Weihs, T. P. (2002) · Archives of Oral Biology · doi:10.1016/s0003-9969(02)00006-7 · Cited by 721 · cited 4×
“The extreme hypermineralization of ACC at the exposed joint surface and the concomitant high modulus (> 30 GPa) may be evidence that the tissue matrix itself is damaged or degraded in these regions.”
BackgroundInfluentialLi, B., & Dr. Aspden, R. M. (1997) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1997.12.4.641 · Cited by 457 · cited 1×
“Thus although the material properties are of a lower grade, the stiffness of the resulting architectural whole will be increased (Li & Aspden, 1997).”
BackgroundVariations in the individual thick lamellar properties within osteons by nanoindentation
Rho, J. Y., Zioupos, P., Currey, J. D., & Pharr, G. M. (1999) · Bone · doi:10.1016/s8756-3282(99)00163-5 · Cited by 236 · cited 2×
“Hardness values for SCB are comparable with those reported previously by Rho et al. (1997, 1999) and Zysset et al. (1999).”
MethodThe Mineralization Density of Iliac Crest Bone from Children with Osteogenesis Imperfecta
Boyde, A., Travers, R., Glorieux, F. H., & Jones, S. J. (1999) · Calcified Tissue International · doi:10.1007/s002239900600 · Cited by 194 · cited 3×
“Grey levels were quantified (qBSE) via halogenated dimethacrylate standards to determine variations in degree of mineralization with exact microanatomical location as described by Boyde et al. (1999) (Fig.”
MethodSelf-citationMechanical properties of human trabecular bone lamellae quantified by nanoindentation
Zysset, P. K., Guo, X. E., Hoffler, C. E., Moore, K. E., & Goldstein, S. A. (1998) · Technology and Health Care · doi:10.3233/thc-1998-65-615 · Cited by 90 · cited 2×
“…region in a surface matched our requirements in the ‘nanoindentation’ range (Bell et al. 1992; Oliver & Pharr, 1992; Field & Swain, 1993; Rho et al. 1997, 1999; Lee et al. 1998; Zysset et al. 1998; Bushby, 2001). qBSE was used to measure the degree of mineralization at the exact indentation sites.”
BackgroundMethodHowell, P. G. T., Davy, K. W. M., & BOYDE, A. (1998) · Scanning · doi:10.1002/sca.1998.4950200105 · Cited by 77
Self-citationBrown, S. J., Pollintine, P., Powell, D., Davie, M. W. J., & Sharp, C. A. (2002) · Calcified Tissue International · doi:10.1007/s00223-001-2102-y · Cited by 60 · cited 2×
“The samples used were a subset of slices of human femoral heads from cases reported by Brown et al. (2002). These were obtained at operation or autopsy and stored frozen.”
MethodChanges in primary health care policy: the implications for joint commissioning with social services
Rummery, K. (1998) · Health & Social Care in the Community · doi:10.1046/j.1365-2524.1998.00153.x · Cited by 36
Lee, F. Y., Rho, J. Y., Harten, R., Parsons, J. R., & Behrens, F. F. (1998) · Journal of Pediatric Orthopaedics · doi:10.1097/01241398-199809000-00004 · Cited by 18 · cited 2×
“…region in a surface matched our requirements in the ‘nanoindentation’ range (Bell et al. 1992; Oliver & Pharr, 1992; Field & Swain, 1993; Rho et al. 1997, 1999; Lee et al. 1998; Zysset et al. 1998; Bushby, 2001). qBSE was used to measure the degree of mineralization at the exact indentation sites.”
BackgroundMethod
Cited by
Nanoindentation of biological materials
Ebenstein, D. M., & Pruitt, L. A. (2006) · Nano Today · doi:10.1016/s1748-0132(06)70077-9 · Cited by 479
Functional Attachment of Soft Tissues to Bone: Development, Healing, and Tissue Engineering
Lu, H. H., & Thomopoulos, S. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124656 · Cited by 447
Polymer Fiber Scaffolds for Bone and Cartilage Tissue Engineering
Zhang, Y., Liu, X., Zeng, L., Zhang, J., Zuo, J., Zou, J., Ding, J., & Chen, X. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201903279 · Cited by 294
Characterization of the structure–function relationship at the ligament-to-bone interface
Moffat, K. L., Sun, W.-H. S., Pena, P. E., Chahine, N. O., Doty, S. B., Ateshian, G. A., Hung, C. T., & Lu, H. H. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0712150105 · Cited by 247
“(17) reported a positive correlation between indentation modulus and hardness with mineral content in calcified articular cartilage.”
BackgroundIn situ measurement of transport between subchondral bone and articular cartilage
Pan, J., Zhou, X., Li, W., Novotny, J. E., Doty, S. B., & Wang, L. (2009) · Journal of Orthopaedic Research · doi:10.1002/jor.20883 · Cited by 244
Metadata
- Authors
- Ferguson, V. L., Bushby, A. J., & Boyde, A.
- Venue
- Journal of Anatomy
- Publisher
- Wiley
- Published
- 2003-07-23
- Volume
- 203
- Issue
- 2
- Pages
- 191-202
- ISSN
- 0021-8782 (ISSN-L)
- 1469-7580
- OpenAlex
- W2100333150
- Cited by
- 236
- References
- 13
- FWCI
- 5.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.