The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Robotic Orthosis Lokomat: A Rehabilitation and Research Tool
Abstract
The aim of this article is to introduce the robotic orthosis Lokomat, developed to automate treadmill training rehabilitation of locomotion for spinal cord injured and stroke patients, to the Functional Electrical Stimulation (FES) and Neuromodulation research communities, and to report on our newly conducted research. We first illustrate the primary use of Lokomat in rehabilitation and focus on control aspects and algorithms associated with robotic rehabilitation of locomotion. Then we describe two applications where the Lokomat was used as a research tool. The first application is closed-loop control of the FES-induced shank movement and the second is the development of a neural network model of the spinal locomotor centers. This model was used to derive a neural locomotion controller for the Lokomat.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The effectiveness of Lokomat as an intervention in gait rehabilitation to improve overground walking function in neurological patients has been verified through worldwide clinical studies [26].”
From Recent developments and challenges of lower extremity exoskeletons (2016) · cites this paper as [26]
In the citing paper
“In trajectory tracking control, the predefined trajectories of the lower limb joints, usually collected from healthy individuals, are used as the control targets [26].”
From Recent developments and challenges of lower extremity exoskeletons (2016) · cites this paper as [26]
Citations
Cites
Treadmill training of paraplegic patients using a robotic orthosis.
Colombo, G., Joerg, M., Schreier, R., & Dietz, V. (2000) · PubMed · Cited by 1,114
Hesse, S., Bertelt, C., Jahnke, M. T., Schaffrin, A., Baake, P., Maležič, M., & Mauritz, K.-H. (1995) · Stroke · doi:10.1161/01.str.26.6.976 · Cited by 612
Laufband (Treadmill) Therapy in Incomplete Paraplegia and Tetraplegia
Wernig, A., Nanassy, A., & MÜLLER, S. (1999) · Journal of Neurotrauma · doi:10.1089/neu.1999.16.719 · Cited by 160
Transcutaneous Functional Electrical Stimulator “Compex Motion”
Keller, T., Popović, M. R., Pappas, I. P. I., & Müller, P. (2002) · Artificial Organs · doi:10.1046/j.1525-1594.2002.06934.x · Cited by 82
Impedance Control Based Gait-Pattern Adaptation for a Robotic Rehabilitation Device
Jezernik, S., Jezernik, K., & Morari, M. (2002) · IFAC Proceedings Volumes · doi:10.1016/s1474-6670(17)33971-x · Cited by 13
Controlling the human-robot interaction for robotic rehabilitation of locomotion
Jezernik, S., & Morari, M. (2003) · International Workshop on Advanced Motion Control · doi:10.1109/amc.2002.1026904 · Cited by 12
A NOVEL SLIDING MODE CONTROLLER FOR FUNCTIONAL ELECTRICAL STIMULATION
Jezernik, S., Inderbitzin, P., Keller, T., & Riener, R. (2002) · IFAC Proceedings Volumes · doi:10.3182/20020721-6-es-1901.01342 · Cited by 10
Research works printed but not linked: 2
- Jezernik S, Colombo G, Morari M. Joint-angle trajectory adaptation for the robotic orthosis Lokomat. In: Proceedings of the Workshop on European Scientific and Industrial Collaboration (WESIC). Enschede, The Netherlands, 2001: pp 451–456. (available from http://www.aut.ee.ethz.ch)
- Jezernik S, Inderbitzin P, Keller T. Riener R. Sliding mode control of Functional Electrical Stimulation for knee joint angle tracking. Proceedings of the 7th Vienna International Workshop on Functional Electrical Stimulation. Vienna, 2001: pp 160–163.
Cited by
Sorted by citations
Items 101–200 of 502
Tan, C. K., Kadone, H., Watanabe, H., Marushima, A., Hada, Y., Yamazaki, M., Sankai, Y., Matsumura, A., & Suzuki, K. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00770 · Cited by 37
BioKEX: A bionic knee exoskeleton with proxy-based sliding mode control
Liao, Y., Zhou, Z., & Wang, Q. (2015) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2015.7125087 · Cited by 36
Aras, B. (2019) · Turkish Journal of Physical Medicine and Rehabilitation · doi:10.5606/tftrd.2019.3078 · Cited by 37
Template model inspired leg force feedback based control can assist human walking
Zhao, G., Sharbafi, M. A., Vlutters, M., van Asseldonk, E. H. F., & Andre Seyfarth, A. (2017) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2017.8009293 · Cited by 34
Fukuda, H., Samura, K., Hamada, O., Saita, K., Ogata, T., Shiota, E., Sankai, Y., & Inoue, T. (2015) · Neurologia medico-chirurgica · doi:10.2176/nmc.oa.2014-0431 · Cited by 34
Geometric design of eight-bar wearable devices based on limb physiological contact task
Robson, N. P., & Soh, G. S. (2016) · Mechanism and Machine Theory · doi:10.1016/j.mechmachtheory.2016.02.016 · Cited by 34
Continuous Tracking Control for a Compliant Actuator With Two-Stage Stiffness
Li, X., Pan, Y., Gong, C., & Yu, H. (2016) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2016.2574741 · Cited by 34
Marks, D., Schweinfurther, R., Dewor, A., Huster, T., Paredes, L. P., Zutter, D. D., & Möller, J. C. (2019) · Physiotherapy Research and Reports · doi:10.15761/prr.1000128 · Cited by 34
Anklebot-assisted locomotor training after stroke: A novel deficit-adjusted control approach
Roy, A., Krebs, H. I., Barton, J. E., Macko, R. F., & Forrester, L. W. (2013) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2013.6630869 · Cited by 34
An Adjustable Single Degree-of-Freedom System to Guide Natural Walking Movement for Rehabilitation
Tsuge, B. Y., & McCarthy, J. M. (2016) · Journal of Medical Devices · doi:10.1115/1.4033329 · Cited by 33
Design and evaluation of a parallel-series elastic actuator for lower limb exoskeletons
Zhu, Y., Yang, J., Jin, H., Zang, X., & Zhao, J. (2014) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2014.6907025 · Cited by 33
Pneumatic Interactive Gait Rehabilitation Orthosis: Design and Preliminary Testing
Belforte, G., Eula, G., Appendino, S., & Sirolli, S. A. (2010) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim803 · Cited by 32
Araujo-Gómez, P., Mata, V., Díaz‐Rodríguez, M., Valera, Á., & Page, A. F. (2017) · Journal of Mechanisms and Robotics · doi:10.1115/1.4037800 · Cited by 31
Systematic framework for performance evaluation of exoskeleton actuators
Natali, C. D., Toxiri, S., Ioakeimidis, S., Caldwell, D. G., & Ortiz, J. (2020) · Wearable Technologies · doi:10.1017/wtc.2020.5 · Cited by 31
A novel self-aligning mechanism to decouple force and torques for a planar exoskeleton joint
Schorsch, J. F., Keemink, A. Q. L., Stienen, A. H. A., van der Helm, F. C. T., & Abbink, D. A. (2014) · Mechanical sciences · doi:10.5194/ms-5-29-2014 · Cited by 29
Gait Recognition for Lower Limb Exoskeletons Based on Interactive Information Fusion
Chen, W., Li, J., Zhu, S., Zhang, X., Men, Y., & Wu, H. (2022) · Applied Bionics and Biomechanics · doi:10.1155/2022/9933018 · Cited by 29
Alamdari, A., & Krovi, V. (2015) · doi:10.1115/detc2015-46393 · Cited by 29
Severini, G., Koenig, A. C., Adans-Dester, C. P., Cajigas, I., Cheung, V. C. K., & Bonato, P. (2020) · Scientific Reports · doi:10.1038/s41598-020-61231-8 · Cited by 30
Soleus H-reflex phase-dependent modulation is preserved during stepping within a robotic exoskeleton
Knikou, M., Hajela, N., Mummidisetty, C. K., Xiao, M., & Smith, A. C. (2011) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.12.044 · Cited by 28
Zhang, W., Zhang, W., Ding, X., & Sun, L. (2019) · Journal of Mechanisms and Robotics · doi:10.1115/1.4045847 · Cited by 27
Miura, K., Koda, M., Tamaki, K., Ishida, M., Marushima, A., Funayama, T., Takahashi, H., Noguchi, H., Mataki, K., Yasunaga, Y., et al. (2021) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-021-04421-3 · Cited by 26
A Design Space of Sports Interaction Technology
Postma, D. B. W., van Delden, R. W., Koekoek, J., Walinga, W. W., van Hilvoorde, I. M., van Beijnum, B.-J. F., Salim, F. A., & Reidsma, D. (2022) · Foundations and Trends® in Human–Computer Interaction · doi:10.1561/1100000087 · Cited by 31
Kwon, S., Park, H., Stanley, C. J., Kim, J., Kim, J., & Damiano, D. L. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2187651 · Cited by 26
Calabrò, R. S., Naro, A., Leo, A., & Bramanti, P. (2016) · Journal of Spinal Cord Medicine · doi:10.1080/10790268.2016.1153275 · Cited by 26
The Rehabilitation of Spinal Cord Injury Patients in Europe
Scivoletto, G., Miscusi, M., Forcato, S., Ricciardi, L., Serrao, M., Bellitti, R., & Raco, A. (2017) · Acta neurochirurgica. Supplementum · doi:10.1007/978-3-319-39546-3_31 · Cited by 26
Bosecker, C. J., & Krebs, H. I. (2009) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2009.5209592 · Cited by 27
Swinnen, E., Baeyens, J., Knaepen, K., Michielsen, M., Hens, G., Clijsen, R., Goossens, M., Buyl, R., MEEUSEN, R. R., & Kerckhofs, E. (2014) · Disability and Rehabilitation Assistive Technology · doi:10.3109/17483107.2014.888487 · Cited by 25
Emerging Perspectives in Stroke Rehabilitation
Asín-Prieto, G., Cano‐de‐la‐Cuerda, R., López‐Larraz, E., Metrot, J., Molinari, M., & van Dokkum, L. E. H. (2013) · Biosystems & biorobotics · doi:10.1007/978-3-642-38556-8_1 · Cited by 26
Hyun, D. J., Lim, H., Park, S.-I., & Jung, K. (2017) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-017-0096-2 · Cited by 24
Analysis of relative displacement between the HX wearable robotic exoskeleton and the user’s hand
Cempini, M., Marzegan, A., Rabuffetti, M., Cortese, M., Vitiello, N., & Ferrarin, M. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-147 · Cited by 24
McCabe, J. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.08.0124 · Cited by 24
Rahman, S. M. M. (2012) · IEEE RO-MAN · doi:10.1109/roman.2012.6343725 · Cited by 24
Technological Advances in Interventions to Enhance Poststroke Gait
Sheffler, L. R., & Chae, J. (2013) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/j.pmr.2012.11.005 · Cited by 24
Moon, D.-H., Kim, D., & Hong, Y.-D. (2019) · Sensors · doi:10.3390/s19183960 · Cited by 24
Skidmore, J., & Artemiadis, P. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0140-y · Cited by 26
Gait Rehabilitation Device in Central Nervous System Disease: A Review
Kazuya, K. U. B. O., Miyoshi, T., Kanai, A., & Terashima, K. (2011) · Journal of Robotics · doi:10.1155/2011/348207 · Cited by 23
Zhou, Z., Liao, Y., Wang, C., & Wang, Q. (2016) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2016.7866484 · Cited by 23
Comparison of coil designs for peripheral magnetic muscle stimulation
Goetz, S. M., Herzog, H.-G., Gattinger, N., & Gleich, B. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/5/056007 · Cited by 23
Wang, Y., Liu, Z., & Feng, Z. (2022) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2022.105660 · Cited by 22
Controller Design for Mechanical Impedance Reduction
Woo, H., & Kong, K. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2014.2312795 · Cited by 22
Sin, M., Kim, W., Park, D., Min, Y.-S., Kim, W. J., Cho, K., & Paik, N. (2013) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2013.10.002 · Cited by 21
Rossi, S., Vitiello, N., Lenzi, T., Ronsse, R., Koopman, H. F. J. M., Persichetti, A., Giovacchini, F., Vecchi, F., Ijspeert, A. J., van der Kooij, H., et al. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626409 · Cited by 21
Rehabilitative Soft Exoskeleton for Rodents
Florez, J. M., Shah, M., Moraud, E. M., Wurth, S. M., Baud, L., Zitzewitz, J. V., van den Brand, R., Micera, S., Courtine, G., & Paik, J. K. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2535352 · Cited by 21
Skidmore, J., & Artemiadis, P. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2421822 · Cited by 22
Kadone, H., Kubota, S., Abe, T., Noguchi, H., Miura, K., Koda, M., Shimizu, Y., Hada, Y., Sankai, Y., Suzuki, K., et al. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.00102 · Cited by 21
Qin, F., Zhao, H., Zhen, S., & Zhang, Y. (2020) · Advanced Robotics · doi:10.1080/01691864.2020.1774414 · Cited by 21
Akıncı, M., Burak, M., Kasal, F. Z., Özaslan, E. A., Huri̇, M., & Kurtaran, Z. A. (2024) · Perceptual and Motor Skills · doi:10.1177/00315125241235420 · Cited by 20
Improving the Standing Balance of Paraplegics through the Use of a Wearable Exoskeleton
Emmens, A. R., van Asseldonk, E. H. F., Masciullo, M., Arquilla, M., Pisotta, I., Tagliamonte, N. L., Tamburella, F., Molinari, M., & van der Kooij, H. (2018) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2018.8488066 · Cited by 20
A Water-Hydraulic Upper-Limb Assistive Exoskeleton System with Displacement Estimation
Kosaki, T., & Li, S. (2020) · Journal of Robotics and Mechatronics · doi:10.20965/jrm.2020.p0149 · Cited by 20
Interaction Control for Human-Exoskeletons
Ajayi, M. O., Djouani, K., & Hamam, Y. (2020) · Journal of Control Science and Engineering · doi:10.1155/2020/8472510 · Cited by 20
Synthesis of a 10-Bar Linkage to Guide the Gait Cycle of the Human Leg
Tsuge, B. Y., & McCarthy, J. M. (2015) · doi:10.1115/detc2015-47723 · Cited by 19
Design and analysis of a novel compact compliant actuator with variable impedance
Yu, H., Sunan, H., Gong, C., Toh, S. L., Cruz, M. S., Ghorbel, Y., Zhu, C., & Yin, Y. (2012) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2012.6491131 · Cited by 19
Rajavenkatanarayanan, A., Kanal, V., Tsiakas, K., Calderon, D., Papakostas, M., Abujelala, M., Galib, M., Ford, J., Wylie, G. R., & Makedon, F. S. (2019) · Multimodal Technologies and Interaction · doi:10.3390/mti3010006 · Cited by 19
A review on human intent understanding and compliance control strategies for lower limb exoskeletons
Yang, J., He, Y., Shi, P. A., & Yu, H. (2022) · Proceedings of the Institution of Mechanical Engineers Part I Journal of Systems and Control Engineering · doi:10.1177/09596518221085793 · Cited by 19
Qian, G., Cai, X., Xu, K., Tian, H., Meng, Q., Ossowski, Z. M., & Liang, J. (2023) · Frontiers in Neurology · doi:10.3389/fneur.2022.1005485 · Cited by 20
Meng, W., Zhu, C. J., Liu, H., Liu, Q., & Xie, S. Q. (2024) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2024.3385798 · Cited by 21
Single-Actuator-Based Lower-Limb Soft Exoskeleton for Preswing Gait Assistance
Hsieh, M.-H., Huang, Y. H., Chao, C.-L., Liu, C., Hsu, W.-L., & Shih, W. (2020) · Applied Bionics and Biomechanics · doi:10.1155/2020/5927657 · Cited by 18
Quasi-Passive Resistive Exosuit for Space Activities: Proof of Concept
Natali, C. D., Chini, G., Totaro, M., Lora-Millán, J. S., Rocón, E., Beccai, L., Caldwell, D. G., Visentin, G., & Ortiz, J. (2021) · Applied Sciences · doi:10.3390/app11083576 · Cited by 20
State of the Art Technologies for Exoskeleton Human Lower Extremity Rehabilitation Robots
Hasan, S., & Dhingra, A. K. (2020) · Journal of Mechatronics and Robotics · doi:10.3844/jmrsp.2020.211.235 · Cited by 17
Seo, J.-W., & Kim, H.-S. (2021) · Sensors · doi:10.3390/s21051726 · Cited by 17
Neurorehabilitation robotics: how much control should therapists have?
Hasson, C. J., Manczurowsky, J., Collins, E. C., & Yarossi, M. P. (2023) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2023.1179418 · Cited by 16
Development of a Low-Cost Open-Source Measurement System for Joint Angle Estimation
de Almeida, T. F., Morya, E., Rodrigues, A. C., & Dantas, A. F. O. D. A. (2021) · Sensors · doi:10.3390/s21196477 · Cited by 17
Human Step Rehabilitation Using a Robot Attached to the Pelvis
Aoyagi, D., Inchinose, W. E., Reinkensmeyer, D. J., & Bobrow, J. E. (2004) · doi:10.1115/imece2004-59472 · Cited by 17
Saeed, M. T., Gul, J. Z., Kausar, Z., Mughal, A. M., Din, Z. M. U., & Qin, S. (2022) · Applied Sciences · doi:10.3390/app12083973 · Cited by 16
Design of a Modular Knee-Ankle-Foot-Orthosis Using Soft Actuator for Gait Rehabilitation
Rahman, S. M. M. (2014) · Lecture notes in computer science · doi:10.1007/978-3-662-43645-5_21 · Cited by 16
A Soft Inflatable Wearable Robot for Hip Abductor Assistance: Design and Preliminary Assessment
Yang, H. D., Cooper, M., Akbaş, T., Schumm, L., Orzel, D., & Walsh, C. J. (2020) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob49111.2020.9224283 · Cited by 16
A reconfigurable, tendon-based haptic interface for research into human-environment interactions
Zitzewitz, J. V., Morger, A., Rauter, G., Marchal–Crespo, L., Crivelli, F., Wyss, D., Brückmann, T., & Riener, R. (2012) · Robotica · doi:10.1017/s026357471200046x · Cited by 16
Synthesis of a Mechanism for Human Gait Rehabilitation: An Introductory Approach
Alves, P., Cruz, F., da Silva, L. F., & Flores, P. (2014) · Mechanisms and machine science · doi:10.1007/978-3-319-09411-3_13 · Cited by 16
Lerner, Z. F., Damiano, D. L., & Bulea, T. C. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2550860 · Cited by 16
Hwang, S., Kim, H., Han, Z., Lee, B.-S., Kim, S.-J., Shin, H., Moon, J.-G., Yang, S.-P., Lim, M.-H., Cho, D. Y., et al. (2017) · Annals of Rehabilitation Medicine · doi:10.5535/arm.2017.41.1.34 · Cited by 16
Robotizing Double-Bar Ankle-Foot Orthosis
Noda, T., Takai, A., Teramae, T., Hirookai, E., Hase, K., & Morimoto, J. (2018) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2018.8462911 · Cited by 16
Gait Pattern Adaptation for an Active Lower-Limb Orthosis Based on Neural Networks
Gomes, M. A., Silveira, G. L. M., & Siqueira, A. A. G. (2011) · Advanced Robotics · doi:10.1163/016918611x588899 · Cited by 16
de Seta, V., & Romeni, S. (2025) · Frontiers in Neuroscience · doi:10.3389/fnins.2025.1569148 · Cited by 18
Development Status and Multilevel Classification Strategy of Medical Robots
Guo, Y., Yang, Y., Liu, Y., Li, Q., Cao, F., Feng, M., Wu, H., Li, W., & Kang, Y. (2021) · Electronics · doi:10.3390/electronics10111278 · Cited by 15
Development of an assistive motorized hip orthosis: Kinematics analysis and mechanical design
Olivier, J., Bouri, M., Ortlieb, A., Bleuler, H., & Clavel, R. (2013) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2013.6650495 · Cited by 15
Robotic Coaching of Complex Physical Skills
Litoiu, A., & Scassellati, B. M. (2015) · ACM/IEEE International Conference on Human-Robot Interaction (HRI) · doi:10.1145/2701973.2702726 · Cited by 15
Yao, J., Sado, T., Wang, W., Gao, J., Zhao, Y., Qi, Q., & Mukherjee, M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00795-y · Cited by 14
A comprehensive review on lower limb exoskeleton: from origin to future expectations
Arunkumar, S., & Jayakumar, N. (2024) · International Journal on Interactive Design and Manufacturing (IJIDeM) · doi:10.1007/s12008-024-02076-7 · Cited by 14
Active training research of a lower limb rehabilitation robot based on constrained trajectory
Wang, H., Zhang, D., Lu, H., Feng, Y., Xu, P., Mihai, R.-V., & Vlădăreanu, L. (2015) · International Conference on Advanced Mechatronic Systems · doi:10.1109/icamechs.2015.7287123 · Cited by 14
Inducing self-selected human engagement in robotic locomotion training
Collins, S. H., & Jackson, R. W. (2013) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2013.6650488 · Cited by 14
Towards more efficient robotic gait training: A novel controller to modulate movement errors
Rudt, S., Moos, M., Seppey, S., Riener, R., & Marchal–Crespo, L. (2016) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2016.7523738 · Cited by 14
Toward Standardizing the Classification of Robotic Gait Rehabilitation Systems
Ayad, S., Ayad, M., Megueni, A., Spaich, E. G., & Struijk, L. N. S. A. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2886228 · Cited by 14
Nguyen, T. M., Jackson, R. W., Aucie, Y., de Kam, D., Collins, S. H., & Torres‐Oviedo, G. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00733-y · Cited by 16
Gait-pattern adaptation algorithms based on neural network for lower limbs active orthoses
Gome, M. A., Silveira, G. L. M., & Siqueira, A. A. G. (2009) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2009.5354232 · Cited by 14
Research on the walking gait coordinations of the lower limb rehabilitation robot
Zhang, X., Kong, X., Liu, G., & Wang, Y. (2010) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2010.5723505 · Cited by 14
Enhancing Robotic-Assisted Lower Limb Rehabilitation Using Augmented Reality and Serious Gaming
Vaida, C. L., Rus, G., Tucan, P., Machado, J., Pîslă, A., Zima, I., Bîrlescu, I., & Pisla, D. L. (2024) · Applied Sciences · doi:10.3390/app142412029 · Cited by 13
Design of the workstation for hand rehabilitation based on data glove
Chen, H., Wang, Q., & Cao, L. (2010) · IEEE International Conference on Bioinformatics and Biomedicine Workshops (BIBMW) · doi:10.1109/bibmw.2010.5703907 · Cited by 13
Disturbance observer applications in rehabilitation robotics: an overview
Mohammadi, A., & Dallali, H. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-817450-0.00005-5 · Cited by 13
Virtual Reality and Occupational Therapy
Aran, O. T., Şahın, S., Torpil, B., Demirok, T., & Kayıhan, H. (2017) · InTech eBooks · doi:10.5772/intechopen.68799 · Cited by 13
Marchal–Crespo, L., & Riener, R. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-811995-2.00016-3 · Cited by 13
Proxy-based impedance control of a cable-driven assistive system
Kong, K. (2012) · Mechatronics · doi:10.1016/j.mechatronics.2012.12.002 · Cited by 13
Toward Improving Robotic-Assisted Gait Training: Can Big Data Analysis Help Us?
Carnevale, L., Calabrò, R. S., Celesti, A., Leo, A., Fazio, M. C., Bramanti, P., & Villari, M. (2018) · IEEE Internet of Things Journal · doi:10.1109/jiot.2018.2855937 · Cited by 12
Neuro-Gerontechnologies: Applications and Opportunities
Barresi, G., Zenzeri, J., Tessadori, J., Laffranchi, M., Semprini, M., & Michieli, L. D. (2022) · Studies in computational intelligence · doi:10.1007/978-981-16-8488-3_7 · Cited by 12
Body weight support during robot-assisted walking: Influence on the trunk and pelvis kinematics
Swinnen, E., Baeyens, J., Hens, G., Knaepen, K., Beckwée, D., Michielsen, M., Clijsen, R., & Kerckhofs, E. (2015) · Neurorehabilitation · doi:10.3233/nre-141195 · Cited by 12
Development of rehabilitation support robot for personalized rehabilitation of upper limbs
Furuhashi, Y., Nagasaki, M., Aoki, T., Morita, Y., Ukai, H., & Matsui, N. (2009) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2009.5209525 · Cited by 12
Jayakumar, R. P., Mishra, S., Dannenhoffer, J., & Okamura, A. M. (2012) · IEEE Haptics Symposium · doi:10.1109/haptic.2012.6183826 · Cited by 12
Control Strategies for Gait Tele-Rehabilitation System Based on Parallel Robotics
Bó, A. P. L., Casas, L., Cucho‐Padin, G., Hayashibe, M., & Elías, D. A. (2021) · Applied Sciences · doi:10.3390/app112311095 · Cited by 15
Yan, H., & Yang, C. (2014) · Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science · doi:10.1177/0954406214527578 · Cited by 12
Reflex Control of Robotic Gait Using Human Walking Data
Macleod, C. A., Meng, L., Conway, B. A., & Porr, B. (2014) · PLoS ONE · doi:10.1371/journal.pone.0109959 · Cited by 12
A Hands-Free Interface for Controlling Virtual Electric-Powered Wheelchairs
Gulrez, T., Tognetti, A., Yoon, W. J., Kavakli, M., & Cabibihan, J. (2016) · International Journal of Advanced Robotic Systems · doi:10.5772/62028 · Cited by 12
Metadata
- Authors
- Jezernik, S., Colombo, G., Keller, T., Frueh, H., & Morari, M.
- Affiliations
- University of Zurich (CH)
- Universitätsklinik Balgrist (CH)
- ETH Zurich (CH)
- Corresponding author
- Jezernik, Sašo
- Venue
- Neuromodulation Technology at the Neural Interface
- Publisher
- Elsevier BV
- Published
- 2003-04
- Volume
- 6
- Issue
- 2
- Pages
- 108-115
- ISSN
- 1094-7159 (ISSN-L)
- OpenAlex
- W2105236479
- Cited by
- 503
- References
- 7
- Citations by year
- 2026: 9 · 2025: 14 · 2024: 21 · 2023: 40 · 2022: 28 · 2021: 46 · 2020: 35 · 2019: 45 · 2018: 32 · 2017: 32 · 2016: 25 · 2015: 29 · 2014: 26 · 2013: 29 · 2012: 14
- FWCI
- 2.90
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Neuromodulation Technology at the Neural Interface (publishedVersion)
- PubMed (publishedVersion)
- TECNALIA Publications (Fundación TECNALIA Research & Innovation) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- Lokomat, robotic orthosis, gait rehabilitation, treadmill training, spinal cord injury, stroke, functional electrical stimulation, feedback control
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review