The Artificial Synapse Chip: A Flexible Retinal Interface Based on Directed Retinal Cell Growth and Neurotransmitter Stimulation
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The Artificial Synapse Chip is an evolving design for a flexible retinal interface that aims to improve visual resolution of an electronic retinal prosthesis by addressing cells individually and mimicking the physiological stimulation achieved in synaptic transmission. We describe three novel approaches employed in the development of the Artificial Synapse Chip: (i) micropatterned substrates to direct retinal cell neurite growth to individual stimulation sites; (ii) a prototype retinal interface based on localized neurotransmitter delivery; and (iii) the use of soft materials to fabricate these devices. By patterning the growth of cells to individual stimulation sites, we can improve the selectivity of stimulation and decrease the associated power requirements. Moreover, we have microfabricated a neurotransmitter delivery system based on a 5‐µm aperture in a 500‐nm‐thick silicon nitride membrane overlying a microfluidic channel. This device can release neurotransmitter volumes as small as 2 pL, demonstrating the possibility of chemical‐based prostheses. Finally, we have fabricated and implanted an equivalent device using soft flexible materials that conform to the retinal tissue more effectively. As many of the current retinal prosthesis devices use hard materials and electrical excitation at a lower resolution, our approach may provide more physiologic retinal stimulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Selective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276
Cited by
A microfluidic culture platform for CNS axonal injury, regeneration and transport
Taylor, A. M., Blurton-Jones, M., Rhee, S. W., Cribbs, D. H., Cotman, C. W., & Jeon, N. L. (2005) · Nature Methods · doi:10.1038/nmeth777 · Cited by 1,153
A practical guide to microfluidic perfusion culture of adherent mammalian cells
Kim, L., Toh, Y.-C., Voldman, J., & Yu, H. (2007) · Lab on a Chip · doi:10.1039/b704602b · Cited by 455
Weiland, J. D., Liu, W., & Humayun, M. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100435 · Cited by 371
Electronic retinal implants and artificial vision: journey and present
Mills, J. O., Jalil, A., & Stanga, P. E. (2017) · Eye · doi:10.1038/eye.2017.65 · Cited by 133
Bridging the gap: microfluidic devices for short and long distance cell–cell communication
Vu, T. Q., de Castro, R. M. B., & Qin, L. (2017) · Lab on a Chip · doi:10.1039/c6lc01367h · Cited by 63
Metadata
- Authors
- Peterman, M. C., Mehenti, N. Z., Bilbao, K. V., Lee, C. J., Leng, T., Noolandi, J., Bent, S. F., Blumenkranz, M. S., & Fishman, H. A.
- Venue
- Artificial Organs
- Publisher
- Wiley
- Published
- 2003-10-31
- Volume
- 27
- Issue
- 11
- Pages
- 975-985
- ISSN
- 0160-564X (ISSN-L)
- 1525-1594
- OpenAlex
- W2036153008
- Cited by
- 82
- References
- 1
- FWCI
- 2.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Artificial Synapse Chip: A Flexible Retinal Interface Based on Directed Retinal Cell Growth and Neurotransmitter Stimulation. https://app.cochat.ai/papers/10.1046/j.1525-1594.2003.07307.x
- The paper
- Peterman, M. C., Mehenti, N. Z., Bilbao, K. V., Lee, C. J., Leng, T., Noolandi, J., Bent, S. F., Blumenkranz, M. S., & Fishman, H. A. (2003). The Artificial Synapse Chip: A Flexible Retinal Interface Based on Directed Retinal Cell Growth and Neurotransmitter Stimulation. Artificial Organs. https://doi.org/10.1046/j.1525-1594.2003.07307.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.