Lowering the hemoglobin threshold for transfusion in coronary artery bypass procedures: effect on patient outcome
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
BACKGROUND: There is controversy regarding the application of transfusion triggers in cardiac surgery. The goal of this study was to determine if lowering the hemoglobin threshold for red cell (RBC) transfusion to 8 g per dL after coronary artery bypass graft surgery would reduce blood use without adversely affecting patient outcome. STUDY DESIGN AND METHODS: Consecutive patients (n = 428) undergoing elective primary coronary artery bypass graft surgery were randomly assigned to two groups: study patients (n = 212) received RBC transfusions in the postoperative period if the Hb level was <8 g per dL or if predetermined clinical conditions required RBC support, and control patients (n = 216) were treated according to individual physician's orders (hemoglobin levels <9 g/dL as the institutional guideline). Multiple demographic, procedure‐related, transfusion, laboratory, and outcome data were analyzed. Questionnaires were administered for patient self‐assessment of fatigue and anemia. RESULTS: Preoperative and operative clinical characteristics, as well as the intraoperative transfusion rate, were similar for both groups. There was a significant difference between the postoperative RBC transfusion rates in study (0.9 ± 1.5 RBC units) and control (1.4 ± 1.8 RBC units) groups (p = 0.005). There was no difference in clinical outcome, including morbidity and mortality rates, in the two groups; group scores for self‐assessment of fatigue and anemia were also similar. CONCLUSIONS: A lower Hb threshold of 8 g per dL does not adversely affect patient outcome. Moreover, RBC resources can be saved without increased risk to the patient.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yellen, S. B., Cella, D. F., Webster, K., Blendowski, C., & Kaplan, E. (1997) · Journal of Pain and Symptom Management · doi:10.1016/s0885-3924(96)00274-6 · Cited by 1,964
Adverse Cerebral Outcomes after Coronary Bypass Surgery
Roach, G. W., Kanchuger, M., Mangano, C. M., Newman, M., Nussmeier, N., Wolman, R., Aggarwal, A., Marschall, K., Graham, S. H., Ley, C., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612193352501 · Cited by 1,860
Stehling, L. C., Doherty, D. C., Faust, R. J., Greenburg, A. G., Harrison, C. R., Landers, D. F., Laros, R. K., Pierce, E. C., Prust, R. S., Rosenberg, A. D., et al. (1996) · PubMed · Cited by 894
Loop, F. D., Lytle, B. W., Cosgrove, D. M., Mahfood, S., McHenry, M. C., Goormastic, M., Stewart, R. W., Golding, L. A. R., & Taylor, P. C. (1990) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(90)90136-t · Cited by 741
Human Cardiovascular and Metabolic Response to Acute, Severe Isovolemic Anemia
Weiskopf, R. B. (1998) · JAMA · doi:10.1001/jama.279.3.217 · Cited by 706
Consensus conference. Perioperative red blood cell transfusion
(1988) · JAMA · doi:10.1001/jama.260.18.2700 · Cited by 614
Perioperative Red Blood Cell Transfusion
(1988) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1988.03410180108040 · Cited by 562
Atrial Arrhythmias after Cardiothoracic Surgery
Ommen, S. R., Odell, J. A., & Stanton, M. S. (1997) · New England Journal of Medicine · doi:10.1056/nejm199705153362006 · Cited by 452
Perioperative Blood Transfusion and Postoperative Mortality
Carson, J. L. (1998) · JAMA · doi:10.1001/jama.279.3.199 · Cited by 435
Stover, P. E., Siegel, L. C., Parks, R., Levin, J., Body, S. C., Maddi, R., D'Ambra, M. N., Mangano, D. T., & Spiess, B. D. (1998) · Anesthesiology · doi:10.1097/00000542-199802000-00009 · Cited by 423
NELSON, A. H., FLEISHER, L. A., & ROSENBAUM, S. H. (1993) · Critical Care Medicine · doi:10.1097/00003246-199306000-00013 · Cited by 387
Practice Strategies for Elective Red Blood Cell Transfusion
(1992) · Annals of Internal Medicine · doi:10.7326/0003-4819-116-5-403 · Cited by 344
Practice Parameter for the Use of Fresh-Frozen Plasma, Cryoprecipitate, and Platelets
Cooper, E. S. (1994) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1994.03510340067036 · Cited by 295
The Variability of Transfusion Practice in Coronary Artery Bypass Surgery
Goodnough, L. T. (1991) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1991.03460010086037 · Cited by 291
Comparison of two transfusion strategies after elective operations for myocardial revascularization
Johnson, R. G., Thurer, R. L., Kruskall, M. S., Sirois, C., Gervino, E. V., Critchlow, J., & Weintraub, R. M. (1992) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)34782-8 · Cited by 244
Determinants of Blood Utilization during Myocardial Revascularization
Cosgrove, D. M., Loop, F. D., Lytle, B. W., Gill, C. C., Golding, L. R., Taylor, P. C., & Forsythe, S. B. (1985) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(10)60073-2 · Cited by 209
A model for predicting transfusion after coronary artery bypass grafting
Magovern, J. A., Sakert, T., Benckart, D. H., Burkholder, J. A., Liebler, G. A., Magovern, G. J., & Magovern, G. J. (1996) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(95)00808-x · Cited by 166
Determinants of prolonged mechanical ventilation after coronary artery bypass grafting
Habib, R. H., Zacharias, A., & Engoren, M. (1996) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(96)00565-6 · Cited by 104
Surgenor, D. M., Churchill, W. H., Wallace, E. L., Rizzo, R. J., McGurk, S., Goodnough, L. T., Kao, K.-J., Koerner, T. A. W., Olson, J. D., & Woodson, R. D. (1998) · Transfusion · doi:10.1046/j.1537-2995.1998.38298193094.x · Cited by 68
Perioperative Indications for Red Blood Cell Transfusion—Has the Pendulum Swung Too Far?
Faust, R. J. (1993) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(12)60203-1 · Cited by 28
Use of blood products in cardiac surgery
Renton, M. C., McClelland, D. B., & Sinclair, C. (1997) · Perfusion · doi:10.1177/026765919701200302 · Cited by 20
Cited by
Murphy, G. J., Reeves, B. C., Rogers, C. A., Rizvi, S. I. A., Culliford, L., & Angelini, G. D. (2007) · Circulation · doi:10.1161/circulationaha.107.698977 · Cited by 1,371
Transfusion thresholds and other strategies for guiding allogeneic red blood cell transfusion
Carson, J. L., Stanworth, S. J., Roubinian, N., Fergusson, D. A., Triulzi, D., Doree, C., & Hebert, P. C. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd002042.pub4 · Cited by 1,250
Barkun, A. N., Bardou, M., Kuipers, E. J., Sung, J., Hunt, R. H., Martel, M., Sinclair, P., & for the International Consensus Upper Gastrointestinal Bleeding Conference Group* (2010) · Annals of Internal Medicine · doi:10.7326/0003-4819-152-2-201001190-00009 · Cited by 1,163
Clinical Practice Guidelines From the AABB: Red Blood Cell Transfusion Thresholds and Storage
Carson, J. L., Guyatt, G., Heddle, N. M., Grossman, B. J., Cohn, C. S., Fung, M. K., Gernsheimer, T., Holcomb, J. B., Kaplan, L. J., Katz, L. M., et al. (2016) · JAMA · doi:10.1001/jama.2016.9185 · Cited by 1,113
Red Blood Cell Transfusion: A Clinical Practice Guideline From the AABB*
Carson, J. L., Grossman, B. J., Kleinman, S., Tinmouth, A. T., Marques, M. B., Fung, M. K., Holcomb, J. B., Illoh, O., Kaplan, L. J., Katz, L. M., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-1-201206190-00429 · Cited by 1,084
Metadata
- Authors
- Bracey, A. W., Radovancevic, R., Riggs, S. A., Houston, S., Cozart, H., Vaughn, W. K., Radovancevic, B., McAllister, H. A., & Cooley, D. A.
- Venue
- Transfusion
- Publisher
- Wiley
- Published
- 1999-10
- Volume
- 39
- Issue
- 10
- Pages
- 1070-1077
- ISSN
- 0041-1132 (ISSN-L)
- 1537-2995
- OpenAlex
- W2072224369
- Cited by
- 310
- References
- 22
- FWCI
- 5.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.