Barcode technology: its role in increasing the safety of blood transfusion
The DOI matches its Crossref record.
Abstract
BACKGROUND: Incorrect blood component transfusion is the most frequent serious incident associated with transfusion. Errors responsible for these incidents frequently involve patient misidentification. STUDY DESIGN AND METHODS: This study evaluated a barcode patient identification system involving hand‐held computers for blood sample collection for compatibility testing and the administration of blood. Audit of practice was carried out before and after its introduction. RESULTS: The baseline audit revealed poor practice, particularly in patient identification. Significant improvements were found in the procedure for the administration of blood following the introduction of barcode patient identification, including an improvement from 11.8 to 100 percent in the correct verbal identification of patients (p ≤ 0.001). Similar significant improvements were found in matching verbally stated identification details with details on patient identification wristbands, in correct patient identification before the collection of blood samples, and in the proportion of correctly labeled samples. Staff found the barcode identification system easy to operate and preferred it to standard procedures. CONCLUSIONS: A barcode patient identification system was found to simplify the clinical transfusion process and improve practice. These results provide support for further work on the development of such systems for transfusion and for other hospital procedures requiring patient identification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Vamvakas, E. C., & Blajchman, M. A. (2009) · Blood · doi:10.1182/blood-2008-10-167643 · Cited by 621
Increased risk of incident HIV during pregnancy in Rakai, Uganda: a prospective study
Gray, R. H., Li, X., Kigozi, G., Serwadda, D., Brahmbhatt, H., Wabwire-Mangen, F., Nalugoda, F., Kiddugavu, M., Sewankambo, N., Quinn, T. C., et al. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67481-8 · Cited by 358
Carayon, P., Wetterneck, T. B., Hundt, A. S., Ozkaynak, M., DeSilvey, J., Ludwig, B., Ram, P., & Rough, S. S. (2007) · Journal of Patient Safety · doi:10.1097/pts.0b013e3180319de7 · Cited by 117
Cresswell, K. M., & Sheikh, A. (2008) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2007.12.1180 · Cited by 38
Metadata
- Authors
- Turner, C. L., Casbard, A. C., & Murphy, M. F.
- Venue
- Transfusion
- Publisher
- Wiley
- Published
- 2003-08-15
- Volume
- 43
- Issue
- 9
- Pages
- 1200-1209
- ISSN
- 0041-1132 (ISSN-L)
- 1537-2995
- OpenAlex
- W2068356346
- Cited by
- 163
- References
- 0
- FWCI
- 16.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Barcode technology: its role in increasing the safety of blood transfusion. https://app.cochat.ai/papers/10.1046/j.1537-2995.2003.00428.x
- The paper
- Turner, C. L., Casbard, A. C., & Murphy, M. F. (2003). Barcode technology: its role in increasing the safety of blood transfusion. Transfusion. https://doi.org/10.1046/j.1537-2995.2003.00428.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.