Information technology-based approaches to reducing repeat drug exposure in patients with known drug allergies
Open accessAbstract
There is increasing interest internationally in ways of reducing the high disease burden resulting from errors in medicine management. Repeat exposure to drugs to which patients have a known allergy has been a repeatedly identified error, often with disastrous consequences. Drug allergies are immunologically mediated reactions that are characterized by specificity and recurrence on reexposure. These repeat reactions should therefore be preventable. We argue that there is insufficient attention being paid to studying and implementing system-based approaches to reducing the risk of such accidental reexposure. Drawing on recent and ongoing research, we discuss a number of information technology-based interventions that can be used to reduce the risk of recurrent exposure. Proven to be effective in this respect are interventions that provide real-time clinical decision support; also promising are interventions aiming to enhance patient recognition, such as bar coding, radiofrequency identification, and biometric technologies.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Problems such as inaccurate allergy coding, spurious alerts that frustrate users and prompt inappropriate clinical responses, and workarounds that bypass safety features have been identified.
“inaccurate coding of allergies, 9 spurious alerts incurring user frustration and inappropriate clinical responses, 10 19 and workarounds which bypass intrinsic safety features 15 have been identified.”
From ‘Too much, too late’: mixed methods multi-channel video recording study of computerized decision support systems and GP prescribing (2013) · cites this paper as [19]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Bates, D. W. (1998) · JAMA · doi:10.1001/jama.280.15.1311 · Cited by 2,107 · see citing works
Clinical Aspects of Immunology.
(1969) · Annals of Internal Medicine · doi:10.7326/0003-4819-71-1-229_2 · Cited by 1,526 · see citing works
Systems Analysis of Adverse Drug Events
Leape, L. L. (1995) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1995.03530010049034 · Cited by 1,404 · see citing works
Adverse Drug Events in Ambulatory Care
Gandhi, T. K., Weingart, S. N., Borus, J. S., Seger, A. C., Peterson, J. F., Burdick, E., Seger, D. L., Shu, K. M., Federico, F. A., Leape, L. L., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmsa020703 · Cited by 1,371 · see citing works
A Computer-Assisted Management Program for Antibiotics and Other Antiinfective Agents
Evans, R. S., Pestotnik, S. L., Classen, D. C., Clemmer, T. P., Weaver, L. K., Orme, J. F., Lloyd, J. F., & Burke, J. P. (1998) · New England Journal of Medicine · doi:10.1056/nejm199801223380406 · Cited by 1,060 · see citing works
Factors Related to Errors in Medication Prescribing
Lesar, T. S. (1997) · JAMA · doi:10.1001/jama.1997.03540280050033 · Cited by 734 · see citing works
Medication Prescribing Errors in a Teaching Hospital
Lesar, T. S. (1990) · JAMA · doi:10.1001/jama.1990.03440170051035 · Cited by 397 · see citing works
Patterson, E. S., Cook, R. I., & Render, M. L. (2002) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1061 · Cited by 370 · see citing works
Franklin, B. D., O'Grady, K., Donyai, P., Jacklin, A., & Barber, N. (2007) · BMJ Quality & Safety · doi:10.1136/qshc.2006.019497 · Cited by 315 · see citing works
Potential of electronic personal health records
Pagliari, C., Detmer, D. E., & Singleton, P. (2007) · BMJ · doi:10.1136/bmj.39279.482963.ad · Cited by 306 · see citing works
Building a safer NHS for patients: improving medication safety
Smith, J., & Cavell, G. F. (2004) · Cited by 284 · see citing works
Hsieh, T. C., Kuperman, G. J., Jaggi, T., Hojnowski-Diaz, P., Fiskio, J., Williams, D. H., Bates, D. W., & Gandhi, T. K. (2004) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1556 · Cited by 232 · see citing works
VERVLOET, D., & Durham, S. K. (1998) · BMJ · doi:10.1136/bmj.316.7143.1511 · Cited by 182 · see citing works
Barcode technology: its role in increasing the safety of blood transfusion
Turner, C. L., Casbard, A. C., & Murphy, M. F. (2003) · Transfusion · doi:10.1046/j.1537-2995.2003.00428.x · Cited by 166 · see citing works
Computerization Can Create Safety Hazards: A Bar-Coding Near Miss
McDonald, C. J. (2006) · Annals of Internal Medicine · doi:10.7326/0003-4819-144-7-200604040-00010 · Cited by 146 · see citing works
Comparison of international guidelines for the emergency medical management of anaphylaxis
Alrasbi, M., & Sheikh, A. (2007) · Allergy · doi:10.1111/j.1398-9995.2007.01434.x · Cited by 98 · see citing works
Medication Errors : Causes, Prevention, and Risk Management
Cohen, M. R. (1999) · Medical Entomology and Zoology · Cited by 94 · see citing works
Adkinson, N. F., Essayan, D. M., Gruchalla, R. S., Haggerty, H. G., Kawabata, T. T., Sandler, J. D., Updyke, L. W., Shear, N. H., & Wierda, D. (2002) · Journal of Allergy and Clinical Immunology · doi:10.1067/mai.2002.122214 · Cited by 87 · see citing works
Fernando, B., Savelyich, B. S. P., Avery, A. J., Sheikh, A., Bainbridge, M., Horsfield, P., & Teasdale, S. (2004) · BMJ · doi:10.1136/bmj.328.7449.1171 · Cited by 70 · see citing works
Effective drug-allergy checking: methodological and operational issues
Kuperman, G. J., Gandhi, T. K., & Bates, D. W. (2003) · Journal of Biomedical Informatics · doi:10.1016/s1532-0464(03)00063-7 · Cited by 53 · see citing works
Patient safety features of clinical computer systems: questionnaire survey of GP views
Morris, C. J. (2005) · BMJ Quality & Safety · doi:10.1136/qshc.2004.011866 · Cited by 37 · see citing works
Radio frequency identification for prevention of bedside errors
Dzik, S. (2007) · Transfusion · doi:10.1111/j.1537-2995.2007.01367.x · Cited by 34 · see citing works
Gomes, E. R., Pichler, W. J., Demoly, P. M., Aberer, W., Frew, A. J., Weck, A. D., & and the EAACI interest group on dru (2005) · Allergy & Clinical Immunology International - Journal of the World Allergy Organization · doi:10.1027/0838-1925.17.1.9 · Cited by 17 · see citing works
Marconi, M., Langeberg, A., Sirchia, G., & Sandler, S. G. (2000) · Immunohematology · doi:10.21307/immunohematology-2019-583 · Cited by 12 · see citing works
Flagged first, then by citations
2 of the 26 references couldn’t be matched to a known paper.
Research works printed but not linked: 6
- Adkinson NF Jr, Friedmann PS, Pongracic JA. Drug Allergy. In: Holgate ST, Church MK, Lichtenstein LM, editors. Allergy. 3rd ed. London: Mosby Elsevier; 2006. p. 157-66.
- Evans RS, Pestotnik SL, Classen DC, Clemmer TP, Weaver LK, Orme JF, et al. A computer-assisted management program for antibiotics and other anti-infective agents. N Engl J Med 1998;338:232-8.
- Gandhi TK, Weingart SN, Borus J, Seger AC, Peterson J, Burdick E. Adverse drug events in ambulatory care. N Engl J Med 2003;348:1556-64.
- Marconi M, Langeberg AF, Sirchia G, Sandler SG. Improving transfusion safety by electronic identification of patients, blood samples, and blood units. Immuno- hematology 2000;16:82-5.
- Turner CL, Casbard AC, Murphy MF. Barcode technology: its role in increasing the safety of blood transfusion. Transfusion 2003;43:1200-9.
- Franklin BD, O'Grady K, Donyai P, Jacklin A, Barber N. The impact of a closed- loop electronic prescribing and administration system on prescribing errors, ad- ministration errors and staff time: a before-and-after study. Qual Saf Health Care 2007;16:279-84.
Cited by
Sorted by citations
Sicherer, S. H., & Leung, D. Y. M. (2009) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2008.12.025 · Cited by 340 · see citing works
A literature review of RFID-enabled healthcare applications and issues
Wamba, S. F., Anand, A., & Carter, L. D. (2013) · International Journal of Information Management · doi:10.1016/j.ijinfomgt.2013.07.005 · Cited by 197 · see citing works
Clinical Decision Support Systems for Drug Allergy Checking: Systematic Review
Légat, L., Laere, S. V., Nyssen, M., Steurbaut, S., Dupont, A. G., & Cornu, P. (2018) · Journal of Medical Internet Research · doi:10.2196/jmir.8206 · Cited by 91 · see citing works
Carson‐Stevens, A., Hibbert, P. D., Williams, H., Evans, H. P., Cooper, A., Rees, P., Deakin, A., Shiels, E., Gibson, R., Butlin, A., et al. (2016) · Health Services and Delivery Research · doi:10.3310/hsdr04270 · Cited by 80 · see citing works
Rees, P., Edwards, A., Powell, C., Hibbert, P. D., Williams, H., Makeham, M., Carter, B., Luff, D. F., Parry, G. J., Avery, A. J., et al. (2017) · PLoS Medicine · doi:10.1371/journal.pmed.1002217 · Cited by 78 · see citing works
Nurmatov, U. B., Worth, A., & Sheikh, A. (2008) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2008.05.028 · Cited by 75 · see citing works
RFID-Enabled Healthcare Applications, Issues and Benefits: An Archival Analysis (1997–2011)
Wamba, S. F. (2011) · Journal of Medical Systems · doi:10.1007/s10916-011-9807-x · Cited by 58 · see citing works
Were, M. C., Shen, C., Tierney, W. M., Mamlin, J. J., Biondich, P., Li, X., Kimaiyo, S., & Mamlin, B. W. (2011) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.2010.005520 · Cited by 50 · see citing works
Hayward, J., Thomson, F., Milne, H., Buckingham, S., Sheikh, A., Fernando, B., Cresswell, K., Williams, R., & Pinnock, H. (2013) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2012-001484 · Cited by 48 · see citing works
Unveiling the Potential of RFID-Enabled Intelligent Patient Management: Results of a Delphi Study
Wamba, S. F., & Ngai, E. W. T. (2011) · Hawaii International Conference on System Sciences (HICSS) · doi:10.1109/hicss.2011.468 · Cited by 23 · see citing works
Approaches to Recording Drug Allergies in Electronic Health Records: Qualitative Study
Fernando, B., Morrison, Z., Kalra, D., Cresswell, K. M., & Sheikh, A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0093047 · Cited by 21 · see citing works
Wamba, S. F., & Ngai, E. W. T. (2012) · Hawaii International Conference on System Sciences (HICSS) · doi:10.1109/hicss.2012.315 · Cited by 19 · see citing works
Internet of Things in healthcare: the case of RFID-enabled asset management
Wamba, S. F., & Ngai, E. W. T. (2013) · International Journal of Biomedical Engineering and Technology · doi:10.1504/ijbet.2013.055379 · Cited by 16 · see citing works
Management of anaphylaxis in the emergency setting
Worth, A., Soar, J., & Sheikh, A. (2009) · Expert Review of Clinical Immunology · doi:10.1586/eci.09.73 · Cited by 16 · see citing works
Karapinar‐Çarkit, F., van Breukelen, B. R. L., Borgsteede, S. D., Janssen, M. J. A., Egberts, T. C. G., & van den Bemt, P. M. L. A. (2014) · International Journal of Clinical Pharmacy · doi:10.1007/s11096-014-9965-2 · Cited by 13 · see citing works
Panesar, S. S., Carson‐Stevens, A., Salvilla, Patel, Mirza, & Mann, M. D. (2013) · Drug Healthcare and Patient Safety · doi:10.2147/dhps.s40887 · Cited by 13 · see citing works
Identifying and Reconciling Patients’ Allergy Information Within the Electronic Health Record
Vallamkonda, S., Ortega, C. A., Lo, Y.-C., Blackley, S. V., Wang, L., Seger, D. L., Blumenthal, K. G., Plasek, J. M., Goss, F. R., & Zhou, L. (2022) · Studies in health technology and informatics · doi:10.3233/shti220044 · Cited by 12 · see citing works
Capture and Documentation of Coded Data on Adverse Drug Reactions: An Overview
Paul, L. J., & Robinson, K. M. (2012) · Health Information Management Journal · doi:10.1177/183335831204100304 · Cited by 11 · see citing works
Overcoming the challenges of iris scanning to identify minors (1–4 years) in the real-world setting
Masyn, S., Vuchelen, A., Santermans, E., Rasschaert, F., Bangura, A. S., Parys, W., & Rutten, R. (2019) · BMC Research Notes · doi:10.1186/s13104-019-4485-8 · Cited by 11 · see citing works
Patient safety in orthopaedics
Panesar, S. S., Shaerf, D. A., Mann, B., & Malik, A. K. (2012) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.94b12.30217 · Cited by 8 · see citing works
Panesar, S. S., Netuveli, G., Carson‐Stevens, A., Javad, S., Patel, B. H., Parry, G. J., Donaldson, L., & Sheikh, A. (2013) · BMJ Open · doi:10.1136/bmjopen-2013-003448 · Cited by 7 · see citing works
RFID in Health Care-Building Smart Hospitals for Quality Healthcare
Manzoor, A. (2017) · IGI Global eBooks · doi:10.4018/978-1-5225-3926-1.ch043 · Cited by 7 · see citing works
Real-Time Clinical Decision Support at the Point of Care
Pereira, A. M., Jácome, C. I. O., Amaral, R., Jacinto, T., & Fonseca, J. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-813471-9.00022-0 · Cited by 7 · see citing works
Apter, A. J. (2009) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2008.11.017 · Cited by 7 · see citing works
Kenna, P. M., Masyn, S., Willems, A., Paepe, A. D., Rutten, R., Mazarati, J. B., Sayinzoga, F., Karita, E., Nduwamungu, J. N., Mazzei, A., et al. (2021) · Human Vaccines & Immunotherapeutics · doi:10.1080/21645515.2021.1920872 · Cited by 6 · see citing works
RFID in Health Care-Building Smart Hospitals for Quality Healthcare
Manzoor, A. (2016) · International Journal of User-Driven Healthcare · doi:10.4018/ijudh.2016070102 · Cited by 6 · see citing works
Prevention of anaphylaxis in healthcare settings
Worth, A., & Sheikh, A. (2013) · Expert Review of Clinical Immunology · doi:10.1586/1744666x.2013.828871 · Cited by 4 · see citing works
Manzoor, A. (2016) · International Journal of Information Communication Technologies and Human Development · doi:10.4018/ijicthd.2016040103 · Cited by 3 · see citing works
Identification of surgical instruments using UHF-RFID technology
Bourouah, M., Goridko, V., Schumacher, D., Scheithauer, H., Knappmann, S., & Nommensen, P. (2015) · Current Directions in Biomedical Engineering · doi:10.1515/cdbme-2015-0079 · Cited by 3 · see citing works
Boguniewicz, M., & Leung, D. Y. M. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4377-0755-7.00146-9 · Cited by 3 · see citing works
Rhyou, H., Kim, S., Jung, J., Kim, S., Lee, J., Park, H. J., Park, K. H., Park, H. S., Chung, E., Choi, G., et al. (2025) · Clinical and Translational Allergy · doi:10.1002/clt2.70047 · Cited by 2 · see citing works
Analyzing the Effects of a BCMA in Inter-Provider Communication, Coordination and Cooperation
Yücel, G., Höge, B., Duffy, V. G., & Roetting, M. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02809-0_79 · Cited by 2 · see citing works
Kormari, E., Pertselakis, M., Pateritsas, C., Siolas, G., Stafylopatis, A., & Gumma, F. (2009) · IEEE International Conference on Information Technology and Applications in Biomedicine · doi:10.1109/itab.2009.5394366 · Cited by 1 · see citing works
RFID Applications in Healthcare-State-of-the-Art and Future Trends
Manzoor, A. (2015) · Advances in healthcare information systems and administration book series · doi:10.4018/978-1-4666-9446-0.ch012 · Cited by 1 · see citing works
RFID Applications in Healthcare-State-of-the-Art and Future Trends
Manzoor, A. (2017) · IGI Global eBooks · doi:10.4018/978-1-5225-2237-9.ch071 · Cited by 1 · see citing works
(2009) · Current Opinion in Allergy and Clinical Immunology · doi:10.1097/aci.0b013e32832eb836
Manzoor, A. (2017) · IGI Global eBooks · doi:10.4018/978-1-5225-3926-1.ch038
Ferreira, V. A. D. L., Alves, M. R., Pinto, P. M., Wanderley, S. B., Marretto, N. B., de Andrade, C. P., Santana, T. D. A., de Brito, Z. A. A., Neto, C. G. D. A., & Ribeiro, V. H. S. (2024) · Revista Ibero-Americana de Humanidades, Ciências e Educação · doi:10.51891/rease.v10i4.13709
- Authors
- Cresswell, K. M., & Sheikh, A.
- Affiliations
- University of Edinburgh (GB)
- Corresponding author
- Sheikh, Aziz
- Venue
- Journal of Allergy and Clinical Immunology
- Publisher
- Elsevier BV
- Published
- 2008-05
- Volume
- 121
- Issue
- 5
- Pages
- 1112-1117.e7
- ISSN
- 0091-6749 (ISSN-L)
- OpenAlex
- W1971814165
- Cited by
- 38
- References
- 26
- Citations by year
- 2025: 1 · 2024: 1 · 2022: 1 · 2021: 1 · 2019: 1 · 2018: 2 · 2017: 4 · 2016: 3 · 2015: 2 · 2014: 2 · 2013: 6 · 2012: 3
- FWCI
- 0.94
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Allergy and Clinical Immunology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
- Health Sciences › Health Professions › Emergency Medical Services › Patient Safety and Medication Errors
- Health Sciences › Medicine › Pharmacology › Drug-Induced Adverse Reactions
- Keywords
- drug hypersensitivity, medication errors, clinical decision support, barcoding, radio frequency identification, patient identification, drug safety
- MeSH terms
- Drug Hypersensitivity, Humans, Hypersensitivity, Medication Errors, Medication Systems, Hospital, Clinical Pharmacy Information Systems
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review