Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 283

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Electrocardiographic Patterns of Superior Right Ventricular Outflow Tract Tachycardias: Distinguishing Septal and Free‐Wall Sites of Origin

Open access
DIXIT, SANJAY, GERSTENFELD, EDWARD P., CALLANS, DAVID J., MARCHLINSKI, FRANCIS E. · 2003 · Journal of Cardiovascular Electrophysiology

Abstract

ECG Patterns of RVOT Tachycardias. Introduction: The superior right ventricular outflow tract (RVOT) septum and free wall are common locations of origin for outflow tract ventricular tachycardias (VT). We hypothesized that (1) unique ECG morphologies of pace maps from septal and free‐wall sites in the superior RVOT could be identified using magnetic electroanatomic mapping for accurate anatomical localization; and (2) this ECG information could help facilitate pace mapping and accurate VT localization. Methods and Results: In 14 patients with structurally normal hearts who were undergoing ablation for outflow tract VT, a detailed magnetic electroanatomic map of RVOT was constructed in sinus rhythm, then pace mapping was performed from anterior, mid, and posterior sites along the septum and free wall of the superior RVOT. Pace maps were analyzed for ECG morphologies in limb leads and transition patterns in precordial leads. Monophasic R waves in inferior leads for septal sites were taller ( 1.7 ± 0.4 mV vs 1.1 ± 0.3 mV; P < 0.01 ) and narrower ( 158 ± 21 msec vs 168 ± 15 msec; P < 0.01 ) compared with free‐wall sites; lacked “notching” (28.6% vs 95.2%; P < 0.05 ); and showed early precordial transition (by lead V 4; 78.6% vs 4.8%; P < 0.05 ). A positive R wave in lead I also distinguished posterior from anterior septal and free‐wall sites. Based on QRS morphology in limb leads and precordial transition pattern (early vs late), in a retrospective analysis, a blinded reviewer was able to accurately localize the site of origin of clinical arrhythmia (the successful ablation site on the magnetic electroanatomic map) in 25 of 28 patients (90%) with superior RVOT VT. Conclusion: Pace maps in the superior RVOT region manifest site‐dependent ECG morphologies that can help in differentiating free‐wall from septal locations and posterior from anterior locations. Despite overlap in QRS amplitude and duration, in the majority of patients a combination of ECG features can serve as a useful template in predicting accurately the site of origin of clinical arrhythmias arising from this region.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1540-8167.2003.02404.x

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 283

Metadata

Authors
DIXIT, S., GERSTENFELD, E. P., CALLANS, D. J., & MARCHLINSKI, F. E.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2003-01
Volume
14
Issue
1
Pages
1-7
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2105337807
Cited by
283
References
13
FWCI
10.27
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.