Operation of a fault tolerant PM drive for an aerospace fuel pump application
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In many applications the failure of a drive has a serious impact on the operation of a system. In some cases the failure results in lost production, whilst in others it may jeopardize human safety. In such applications it is advantageous to use a drive capable of continuing to operate in the presence of any single point failure. Such a drive is termed fault tolerant and the development of a fault tolerant drive is the aim of the research presented. Previous work by B.C. Mecrow et al. (see Seventh International Conference on Electric Machines and Drives, Durham, UK, IEE, p.443-7, 1995) has introduced the concept of a fault tolerant permanent magnet (PM) machine drive for safety critical applications. This drive was based on a novel design of PM machine with a high per unit reactance to limit fault currents. It is shown by A.G. Jack et al. (see IEEE Trans. Ind. Appls., vol.32, no.4, p.889-95, 1996) that the torque and power densities of this PM drive exceed those possible with an SRM drive. This previous work was undertaken on a small prototype machine without a power electronic converter. A new drive has now been built and extensively tested. It uses a similar topology to the prototype machine and is designed to an aircraft fuel pump specification, requiring 16 kW at 13000 rpm. This paper reports the key design attributes and provides detailed measured parameters. The machine is controlled by a power electronic converter using a separate H bridge to drive each phase. The controller, implemented via a DSP, uses the measured machine flux linkage to provide robust current control with high dynamic performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fault-tolerant permanent magnet machinedrives
Mecrow, B. C., Jack, A. G., Haylock, J. A., & Coles, J. (1996) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:19960796 · Cited by 376
Self-citation
Cited by
EL-Refaie, A. M. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2030211 · Cited by 1,373
Fault-Tolerant Interior-Permanent-Magnet Machines for Hybrid Electric Vehicle Applications
Parsa, L., & Toliyat, H. A. (2007) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2007.896978 · Cited by 317
On advantages of multi-phase machines
Parsa, L. (2005) · 31st Annual Conference of IEEE Industrial Electronics Society, 2005. IECON 2005. · doi:10.1109/iecon.2005.1569139 · Cited by 298
Fault-Tolerant Control of Five-Phase Permanent-Magnet Motors With Trapezoidal Back EMF
Dwari, S., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2045322 · Cited by 289
Strategies for the Fault-Tolerant Current Control of a Five-Phase Permanent-Magnet Motor
Bianchi, N., Bolognani, S., & Dai Pre, M. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.900445 · Cited by 276
Metadata
- Authors
- Haylock, J. A.
- Venue
- Eighth International Conference on Electrical Machines and Drives
- Publisher
- IEE
- Published
- 1997
- Volume
- 1997
- Pages
- 133-137
- OpenAlex
- W2147617390
- Cited by
- 101
- References
- 1
- FWCI
- 1.29
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Operation of a fault tolerant PM drive for an aerospace fuel pump application. https://app.cochat.ai/papers/10.1049/cp:19971053
- The paper
- Haylock, J. A. (1997). Operation of a fault tolerant PM drive for an aerospace fuel pump application. Eighth International Conference on Electrical Machines and Drives. https://doi.org/10.1049/cp%3A19971053
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.