The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Using SCADA data for wind turbine condition monitoring – a review
Open accessAbstract
The ever increasing size of wind turbines and the move to build them offshore have accelerated the need for optimised maintenance strategies in order to reduce operating costs. Predictive maintenance requires detailed information on the condition of turbines. Due to the high costs of dedicated condition monitoring systems based on mainly vibration measurements, the use of data from the turbine supervisory control and data acquisition (SCADA) system is appealing. This review discusses recent research using SCADA data for failure detection and condition monitoring (CM), focussing on approaches which have already proved their ability to detect anomalies in data from real turbines. Approaches are categorised as (i) trending, (ii) clustering, (iii) normal behaviour modelling, (iv) damage modelling and (v) assessment of alarms and expert systems. Potential for future research on the use of SCADA data for advanced turbine CM is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jang, J. S. R., Sun, C. T., & Mizutani, E. (1997) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1997.633847 · Cited by 1,672
Condition monitoring and fault detection of wind turbines and related algorithms: A review
Hameed, Z., Hong, Y. S., Cho, Y. M., Ahn, S. H., & Song, C. K. (2009) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2007.05.008 · Cited by 995
Condition monitoring of wind turbines: Techniques and methods
García Márquez, F. P., Tobias, A. M., Pinar Pérez, J. M., & Papaelias, M. (2012) · Renewable Energy · doi:10.1016/j.renene.2012.03.003 · Cited by 878
Survey of Failures in Wind Power Systems With Focus on Swedish Wind Power Plants During 1997–2005
Ribrant, J., & Bertling, L. M. (2007) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.889614 · Cited by 757
Failure rate, repair time and unscheduled O&M cost analysis of offshore wind turbines
Carroll, J., McDonald, A., & McMillan, D. (2015) · Wind Energy · doi:10.1002/we.1887 · Cited by 660
Reliability of wind turbine subassemblies
Spinato, F., Tavner, P. J., van Bussel, G. J. W., & Koutoulakos, E. (2009) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2008.0060 · Cited by 646
Wind Turbine Condition Monitoring: State-of-the-Art Review, New Trends, and Future Challenges
Tchakoua, P., Wamkeue, R., Ouhrouche, M., Slaoui-Hasnaoui, F., Tameghe, T., & Ekemb, G. (2014) · Energies · doi:10.3390/en7042595 · Cited by 604
A Survey on Wind Turbine Condition Monitoring and Fault Diagnosis—Part I: Components and Subsystems
Qiao, W., & Lu, D. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2422112 · Cited by 533
Reliability analysis for wind turbines
Tavner, P. J., Xiang, J., & Spinato, F. (2007) · Wind Energy · doi:10.1002/we.204 · Cited by 494
Wind turbine condition monitoring: technical and commercial challenges
Yang, W., Tavner, P. J., Crabtree, C. J., Feng, Y., & Qiu, Y. (2014) · Wind Energy · doi:10.1002/we.1508 · Cited by 474
Online wind turbine fault detection through automated SCADA data analysis
Zaher, A., McArthur, S. D. J., Infield, D. G., & Patel, Y. (2009) · Wind Energy · doi:10.1002/we.319 · Cited by 464
The prediction and diagnosis of wind turbine faults
Kusiak, A., & Li, W. (2011) · Renewable Energy · doi:10.1016/j.renene.2010.05.014 · Cited by 454
Qiao, W., & Lu, D. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2422394 · Cited by 407
Wind turbine condition monitoring by the approach of SCADA data analysis
Yang, W., Court, R., & Jiang, J. (2013) · Renewable Energy · doi:10.1016/j.renene.2012.11.030 · Cited by 400
Schlechtingen, M., & Santos, I. F. (2010) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2010.12.007 · Cited by 370
An Artificial Neural Network Approach for Early Fault Detection of Gearbox Bearings
Bangalore, P., & Tjernberg, L. B. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2386305 · Cited by 339
SIMAP: Intelligent System for Predictive Maintenance
Garcia, M. C., Sanz-Bobi, M. A., & del Pico, J. (2006) · Computers in Industry · doi:10.1016/j.compind.2006.02.011 · Cited by 313
Schlechtingen, M., Santos, I. F., & Achiche, S. (2013) · Applied Soft Computing · doi:10.1016/j.asoc.2012.08.033 · Cited by 311
Monitoring wind turbine gearboxes
Feng, Y., Qiu, Y., Crabtree, C. J., Long, H., & Tavner, P. J. (2013) · Wind Energy · doi:10.1002/we.1521 · Cited by 253
Using Data-Mining Approaches for Wind Turbine Power Curve Monitoring: A Comparative Study
Schlechtingen, M., Santos, I. F., & Achiche, S. (2013) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2013.2241797 · Cited by 224
Analyzing bearing faults in wind turbines: A data-mining approach
Kusiak, A., & Verma, A. (2012) · Renewable Energy · doi:10.1016/j.renene.2012.04.020 · Cited by 219
Offshore Wind Turbines: Reliability, availability and maintenance
Tavner, P. (2012) · Institution of Engineering and Technology eBooks · doi:10.1049/pbrn013e · Cited by 205
Wind Turbine Condition Assessment Through Power Curve Copula Modeling
Gill, S., Stephen, B., & Galloway, S. (2012) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2011.2167164 · Cited by 193
Hahn, B., Durstewitz, M., & Rohrig, K. (2007) · Wind Energy · doi:10.1007/978-3-540-33866-6_62 · Cited by 188
A generalized model for wind turbine anomaly identification based on SCADA data
Sun, P. F., Li, J., Wang, C., & Xiao, L. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.01.133 · Cited by 183
Use of SCADA Data for Failure Detection in Wind Turbines
Kim, K., Parthasarathy, G., Uluyol, Ö., Foslien, W., Sheng, S., & Fleming, P. (2011) · ASME International Conference on Energy Sustainability (ES) · doi:10.1115/es2011-54243 · Cited by 154
Physics of Failure approach to wind turbine condition based maintenance
Gray, C. S., & Watson, S. J. (2009) · Wind Energy · doi:10.1002/we.360 · Cited by 150
Self-citationWind turbine fault detection based on SCADA data analysis using ANN
Zhang, Z., & Wang, K. (2014) · Advances in Manufacturing · doi:10.1007/s40436-014-0061-6 · Cited by 133
Assessment of Condition Monitoring Techniques for Offshore Wind Farms
Wiggelinkhuizen, E. J., Verbruggen, T. W., Braam, H., Rademakers, L. W. M. M., Xiang, J., & Watson, S. J. (2008) · Journal of Solar Energy Engineering · doi:10.1115/1.2931512 · Cited by 124
Self-citationWind turbine SCADA alarm analysis for improving reliability
Qiu, Y., Feng, Y., Tavner, P., Richardson, P., Erdős, G., & Chen, B. (2011) · Wind Energy · doi:10.1002/we.513 · Cited by 123
Wind turbine pitch faults prognosis using a-priori knowledge-based ANFIS
Chen, B., Matthews, P., & Tavner, P. (2013) · Expert Systems with Applications · doi:10.1016/j.eswa.2013.06.018 · Cited by 123
Comparison of methods for wind turbine condition monitoring with SCADA data
Wilkinson, M., Darnell, B., van Delft, T., & Harman, K. (2014) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2013.0318 · Cited by 122
Report on Wind Turbine Subsystem Reliability - A Survey of Various Databases
Sheng, S. (2013) · University of North Texas Digital Library (University of North Texas) · Cited by 115
Applying thermophysics for wind turbine drivetrain fault diagnosis using SCADA data
Qiu, Y., Feng, Y., Sun, J., et al. (2016) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2015.0160 · Cited by 97
Analysis of Wind Turbine Vibrations Based on SCADA Data
Kusiak, A., & Zhang, Z. (2010) · Journal of Solar Energy Engineering · doi:10.1115/1.4001461 · Cited by 79
Wang, Y., & Infield, D. G. (2013) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2012.0215 · Cited by 67
Classification and Detection of Wind Turbine Pitch Faults Through SCADA Data Analysis
Godwin, J. L., & Matthews, P. (2020) · International Journal of Prognostics and Health Management · doi:10.36001/ijphm.2013.v4i3.2146 · Cited by 60
Tracht, K., Goch, G., Schuh, P., Sorg, M., & Westerkamp, J. F. (2013) · CIRP Annals · doi:10.1016/j.cirp.2013.03.130 · Cited by 55
Monitoring Wind Turbine Vibration Based on SCADA Data
Zhang, Z., & Kusiak, A. (2012) · Journal of Solar Energy Engineering · doi:10.1115/1.4005753 · Cited by 54
FAULT PREVENTION AND DIAGNOSIS THROUGH SCADA TEMPERATURE DATA ANALYSIS OF AN ONSHORE WIND FARM
Astolfi, D., Castellani, F., & Terzi, L. (2014) · Institutional Research Information System (Università degli Studi di Brescia) · Cited by 47
Normal Behavior Models for the Condition Assessment of Wind Turbine Generator Systems
Li, J., Xiao, L., Li, H., & Ran, L. (2014) · Electric Power Components and Systems · doi:10.1080/15325008.2014.921954 · Cited by 46
A feasibility study into prognostics for the main bearing of a wind turbine
Butler, S., O'Connor, F., Farren, D., & Ringwood, J. V. (2012) · The proceedings of the IEEE Conference on Control Applications/The proceedings of the ... IEEE Conference on Control Applications · doi:10.1109/cca.2012.6402684 · Cited by 39
Fault Detection in Wind Turbine: A Systematic Literature Review
Purarjomandlangrudi, A., Nourbakhsh, G., Esmalifalak, M., & Tan, A. C. C. (2013) · Wind Engineering · doi:10.1260/0309-524x.37.5.535 · Cited by 23
Cited by
Machine learning methods for wind turbine condition monitoring: A review
Stetco, A., Dinmohammadi, F., Zhao, X., Robu, V., Flynn, D., Barnes, M., Keane, J., & Nenadic, G. (2019) · Renewable Energy · doi:10.1016/j.renene.2018.10.047 · Cited by 831
Fault diagnosis of wind turbine based on Long Short-term memory networks
Lei, J., Liu, C., & Jiang, D. (2019) · Renewable Energy · doi:10.1016/j.renene.2018.10.031 · Cited by 507
Lifetime extension of onshore wind turbines: A review covering Germany, Spain, Denmark, and the UK
Ziegler, L., Gonzalez, E., Rubert, T., Smolka, U., & Melero, J. J. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.09.100 · Cited by 330
Badihi, H., Zhang, Y., Jiang, B., Pillay, P., & Rakheja, S. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3171691 · Cited by 319
Wind Turbine Fault Detection Using a Denoising Autoencoder With Temporal Information
Jiang, G., Xie, P., He, H., & Yan, J. (2018) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2017.2759301 · Cited by 288
Metadata
- Authors
- Tautz‐Weinert, J., & Watson, S. J.
- Venue
- IET Renewable Power Generation
- Published
- 2016-12
- Volume
- 11
- Issue
- 4
- Pages
- 382-394
- ISSN
- 1752-1416 (ISSN-L)
- 1752-1424
- OpenAlex
- W2523553285
- Cited by
- 458
- References
- 43
- FWCI
- 21.60
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.