Wind Turbine Fault Detection Using a Denoising Autoencoder With Temporal Information

Open access
Jiang, Guoqian, Xie, Ping, He, Haibo, Yan, Jun · 2018 · IEEE/ASME Transactions on Mechatronics

Abstract

Data-driven approaches have gained increasing interests in the fault detection of wind turbines (WTs) due to the difficulty in system modeling and the availability of sensor data. However, the nonlinearity of WTs, uncertainty of disturbances and measurement noise, and temporal dependence in time-series data still pose grand challenges to effective fault detection. To this end, this paper proposes a new fault detector based on a recently developed unsupervised learning method, denoising autoencoder (DAE), which offers the learning of robust nonlinear representations from data against noise and input fluctuation. A DAE is used to build a robust multivariate reconstruction model on raw time-series data from multiple sensors, and then, the reconstruction error of the DAE trained with normal data is analyzed for fault detection. In addition, we apply the sliding-window technique to consider temporal information inherent in time-series data by including the current and past information within a small time window. A key advantage of the proposed approach is the ability to capture the nonlinear correlations among multiple sensor variables and the temporal dependence of each sensor variable simultaneously, which significantly enhanced the fault detection performance. Simulated data from a generic WT benchmark and field supervisory control and data acquisition data from a real wind farm are used to evaluate the proposed approach. The results of two case studies demonstrate the effectiv…

Overview

Integrity signals

Registry

Crossref · 10.1109/tmech.2017.2759301

Cites

50 of 50 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 50 references

Research works printed but not linked: 2

  1. 10.1175/1520-0477(1993)074<0615:WMAAUT>2.0.CO;2 · doi:10.1175/1520-0477(1993)074
  2. fawcett, 2004, Roc graphs: Notes and practical considerations for researchers, Mach Learn, 31, 1

Cited by

See all 288

Metadata

Authors
Jiang, G., Xie, P., He, H., & Yan, J.
Affiliations
  • Yanshan University (CN)
  • University of Rhode Island (US)
  • Concordia University (CA)
Venue
IEEE/ASME Transactions on Mechatronics
Published
2018-02
Volume
23
Issue
1
Pages
89-100
ISSN
  • 1083-4435 (ISSN-L)
  • 1941-014X
OpenAlex
W2761148314
Cited by
288
References
50
Citations by year
2026: 17 · 2025: 31 · 2024: 45 · 2023: 34 · 2022: 50 · 2021: 38 · 2020: 35 · 2019: 28 · 2018: 10
FWCI
12.54
Type
journal article
Language
en
Open access
Locations
  • IEEE/ASME Transactions on Mechatronics (publishedVersion)
  • Journal of Media Literacy Education (submittedVersion, cc-by)
Funders
  • National Natural Science Foundation of China (61673336, 51529701)
  • Natural Science Foundation of Hebei Province (F2016203421)
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
  • Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
  • Physical Sciences › Engineering › Civil and Structural Engineering › Structural Health Monitoring Techniques
Keywords
wind turbine fault detection, denoising autoencoder, unsupervised learning, reconstruction error, sliding window, time dependence, time series, multivariate sensor data, SCADA data, wind farms

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Wind Turbine Fault Detection Using a Denoising Autoencoder With Temporal Information. https://app.cochat.ai/papers/10.1109/tmech.2017.2759301
The paper
Jiang, G., Xie, P., He, H., & Yan, J. (2018). Wind Turbine Fault Detection Using a Denoising Autoencoder With Temporal Information. IEEE/ASME Transactions on Mechatronics. https://doi.org/10.1109/tmech.2017.2759301

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.