The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Development of an electromagnetic micro-generator
Abstract
A design methodology for linear micro-generators is developed, and is applied to the design of a mm scale electromagnetic micro-generator. The fabrication of a prototype device is also described using generally available microfabrication techniques, and the results of testing the device on a variable amplitude vibration source, in air and vacuum, are presented. The experimental results confirm the design rules and indicate how the generation of useful power levels might be achieved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnetically actuated, addressable microstructures
Judy, J. W., & Muller, R. S. (1997) · Journal of Microelectromechanical Systems · doi:10.1109/84.623114 · Cited by 256
Development of an electromagnetic micro-generator
Shearwood, C., & Yates, R. B. (1997) · Electronics Letters · doi:10.1049/el:19971262 · Cited by 195
Self-citation
Cited by
Energy harvesting vibration sources for microsystems applications
Beeby, S. P., Tudor, M. J., & White, N. M. (2006) · Measurement Science and Technology · doi:10.1088/0957-0233/17/12/r01 · Cited by 3,008
Energy Harvesting From Human and Machine Motion for Wireless Electronic Devices
Mitcheson, P. D., Yeatman, E. M., Rao, G. K., Holmes, A. S., & Green, T. C. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.927494 · Cited by 1,888
A piezoelectric vibration based generator for wireless electronics
Roundy, S., & Wright, P. K. (2004) · Smart Materials and Structures · doi:10.1088/0964-1726/13/5/018 · Cited by 1,818
A micro electromagnetic generator for vibration energy harvesting
Beeby, S. P., Torah, R. N., Tudor, M. J., Glynne-Jones, P., O'Donnell, T., Saha, C. R., & Roy, S. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/7/007 · Cited by 1,398
Cook-Chennault, K. A., Thambi, N., & Sastry, A. M. (2008) · Smart Materials and Structures · doi:10.1088/0964-1726/17/4/043001 · Cited by 1,241
A comprehensive review on vibration energy harvesting: Modelling and realization
Wei, C., & Jing, X. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.01.073 · Cited by 952
Advances in energy harvesting using low profile piezoelectric transducers
Priya, S. (2007) · Journal of Electroceramics · doi:10.1007/s10832-007-9043-4 · Cited by 918
On energy harvesting from ambient vibration
Stephen, N. G. (2006) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2005.10.003 · Cited by 879
Architectures for Vibration-Driven Micropower Generators
Mitcheson, P. D., Green, T. C., Yeatman, E. M., & Holmes, A. S. (2004) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2004.830151 · Cited by 753
Energy harvesting: State-of-the-art
Harb, A. (2011) · Renewable Energy · doi:10.1016/j.renene.2010.06.014 · Cited by 696
A vibration energy harvesting device with bidirectional resonance frequency tunability
Challa, V. R., Prasad, M. G., Shi, Y., & Fisher, F. T. (2008) · Smart Materials and Structures · doi:10.1088/0964-1726/17/01/015035 · Cited by 675
Kinetic Energy Harvesting Using Piezoelectric and Electromagnetic Technologies—State of the Art
Khaligh, A., Zeng, P., & Zheng, C. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2024652 · Cited by 669
Yang, Y., Zhang, H., Chen, J., Jing, Q., Zhou, Y. S., Wen, X., & Wang, Z. L. (2013) · ACS Nano · doi:10.1021/nn403021m · Cited by 635
Bai, P., Zhu, G., Lin, Z.-H., Jing, Q., Chen, J., Zhang, G., Ma, J., & Wang, Z. L. (2013) · ACS Nano · doi:10.1021/nn4007708 · Cited by 628
Electromagnetic generator for harvesting energy from human motion
Saha, C. R., O’Donnell, T., Wang, N., & McCloskey, P. (2008) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2008.03.008 · Cited by 608
Zhang, C., Tang, W., Han, C., Fan, F., & Wang, Z. L. (2014) · Advanced Materials · doi:10.1002/adma.201400207 · Cited by 606
Review of Microscale Magnetic Power Generation
Arnold, D. P. (2007) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2007.906150 · Cited by 549
Segmentally Structured Disk Triboelectric Nanogenerator for Harvesting Rotational Mechanical Energy
Lin, L., Wang, S., Xie, Y., Jing, Q., Niu, S., Hu, Y., & Wang, Z. L. (2013) · Nano Letters · doi:10.1021/nl4013002 · Cited by 514
A survey of energy harvesting sources for embedded systems
Chalasani, S., & Conrad, J. M. (2008) · IEEE SoutheastCon 2008 · doi:10.1109/secon.2008.4494336 · Cited by 482
A Single‐Electrode Based Triboelectric Nanogenerator as Self‐Powered Tracking System
Yang, Y., Zhou, Y. S., Zhang, H., Liu, Y., Lee, S., & Wang, Z. L. (2013) · Advanced Materials · doi:10.1002/adma.201302453 · Cited by 390
Towards a piezoelectric vibration-poweredmicrogenerator
Glynne-Jones, P., Beeby, S. P., & White, N. M. (2001) · IEE Proceedings - Science, Measurement and Technology · doi:10.1049/ip-smt:20010323 · Cited by 354
Small-scale energy harvesting through thermoelectric, vibration, and radiofrequency power conversion
Hudak, N. S., & Amatucci, G. G. (2008) · Journal of Applied Physics · doi:10.1063/1.2918987 · Cited by 343
Comparison of energy harvesting systems for wireless sensor networks
Gilbert, J. M., & Balouchi, F. (2008) · International Journal of Automation and Computing · doi:10.1007/s11633-008-0334-2 · Cited by 337
Electroactive Polymer-Based Devices for e-Textiles in Biomedicine
Carpi, F., & DeRossi, D. (2005) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.854514 · Cited by 328
Energy harvesting for the implantable biomedical devices: issues and challenges
Hannan, M. A., Mutashar, S., Samad, S. A., & Hussain, A. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-79 · Cited by 322
Review of Power Conditioning for Kinetic Energy Harvesting Systems
Szarka, G. D., Stark, B. H., & Burrow, S. G. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2161675 · Cited by 308
Lin, L., Wang, S., Niu, S., Liu, C., Xie, Y., & Wang, Z. L. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am405637s · Cited by 279
Shin, S.-H., Kwon, Y. H., Kim, Y.-H., Jung, J.-Y., Lee, M. H., & Nah, J. (2015) · ACS Nano · doi:10.1021/acsnano.5b01340 · Cited by 263
Pulsed Nanogenerator with Huge Instantaneous Output Power Density
Cheng, G., Lin, Z.-H., Lin, L., Du, Z.-L., & Wang, Z. L. (2013) · ACS Nano · doi:10.1021/nn403151t · Cited by 261
Survey of energy scavenging for wearable and implantable devices
Ghomian, T., & Mehraeen, S. (2019) · Energy · doi:10.1016/j.energy.2019.04.088 · Cited by 126
Zhu, D., & Beeby, S. (2011) · Energy Harvesting Systems · doi:10.1007/978-1-4419-7566-9_1 · Cited by 62
Metadata
- Authors
- Williams, C. B., Shearwood, C., Harradine, M. A., Mellor, P. H., Birch, T. S., & Yates, R. B.
- Venue
- IEE Proceedings - Circuits, Devices and Systems
- Published
- 2001
- Volume
- 148
- Issue
- 6
- Pages
- 337
- ISSN
- 1350-2409 (ISSN-L)
- OpenAlex
- W1979006073
- Cited by
- 507
- References
- 2
- FWCI
- 13.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.